EEWORLDEEWORLDEEWORLD

Part Number

Search

MA324S05RU

Description
MA300RU SERIES
File Size479KB,2 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet View All

MA324S05RU Overview

MA300RU SERIES

MA300RU
Series
Wide 4:1 Input, 3W,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Key Features:
3W Output Power
4:1 Input Voltage Range
1,500 VDC Isolation
16 Standard Models
Single & Dual Outputs
Compact DIP Case
-40°C to +85°C Operation
Industry Standard Pin-Out
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Start Voltage
Under Voltage Shutdown
Input Filter
Conditions
Min.
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
(Pi)
Filter
Conditions
Dual Output, Balanced Loads
V
IN
= Min to Max
I
OUT
= 0% to 100%
See Note 1
25% Load Step Change
Min.
Typ.
Max.
9.0
18.0
8.5
17.5
Units
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Overload Protection
Output Short Circuit
Typ.
±0.5
±0.3
±0.3
200
±3.0
±0.01
Max.
±2.0
±2.0
±1.0
±1.0
70
500
±5.0
±0.02
Units
%
%
%
%
mV P - P
µSec
%
%/°C
%
3.0 kV Isolation
Models
Available
Foldback
120
Continuous (Autorecovery)
Conditions
60 Seconds
500 VDC
100 kHz/1.0V
Min.
1,500
1,000
90
Standard
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Typ.
Max.
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Units
VDC
M
pF
kHz
2:1 Input Range
Models
Available
500
See Note 3
See Note 3
Level
Class A
Class A
Criteria A; ±8 kV Air ±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±1 kV
Criteria A; 10V/m
Min.
-40
Typ.
+25
Max.
+85
+100
+125
95
Units
°C
°C
°C
%
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
-50
Free Air Convection
RH, Non-condensing
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.45 Oz (12.8g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
1.0
Min.
-0.7
-0.7
Typ.
Max.
Units
MHours
Units
VDC
°C
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Typ.
Max.
50.0
100.0
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
There is no GND in the PCB network marking
Can anyone tell me: I clearly placed the GND network mark when I drew the schematic, but there is no GND network mark in the network report or PCB? I wonder if anyone knows what the reason is? Thank y...
ben007sky2003 PCB Design
Can a multi-turn potentiometer be used for direction detection?
Can a potentiometer that can rotate multiple circles be used to detect the rotation of the steering wheel? What I am considering here is the wear and tear of the potentiometer caused by the speed of r...
WF20142826 Integrated technical exchanges
Oscilloscope DIY kit, with case and circuit diagram
[color=#000][font=tahoma, arial, 宋体, sans-serif] Jinyue Electronics DSO068 Oscilloscope Kit is an oscilloscope production kit suitable for electronic professional teaching and training, as well as per...
bo-scope Buy&Sell
Learn FPGA from Teacher Xia (7) Signals in Verilog Modules
[flash]http://www.tudou.com/v/pF2z8W0HEMo/v.swf[/flash]...
soso FPGA/CPLD
SHT31 evaluation + mobile phone APP connection successful
After spending a few days, I finally downloaded a mobile APP with the help of teacher bigbat. After repeated attempts, I was finally able to receive the data sent by SHT31. This mobile APP is provided...
hujj Special Edition for Assessment Centres
Can the cc2530's udp-client packet pass through the border-router to the external ipv6 server?
Hello everyone, I use CC2530 with Arduino cloud to try to make a border router (border-router), and then I can use a zigduino board's udp-client to send packets through the router to an ipv6 server fo...
k258 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1320  65  768  1102  1361  27  2  16  23  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号