EEWORLDEEWORLDEEWORLD

Part Number

Search

MA324S24RU

Description
MA300RU SERIES
File Size479KB,2 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet View All

MA324S24RU Overview

MA300RU SERIES

MA300RU
Series
Wide 4:1 Input, 3W,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Key Features:
3W Output Power
4:1 Input Voltage Range
1,500 VDC Isolation
16 Standard Models
Single & Dual Outputs
Compact DIP Case
-40°C to +85°C Operation
Industry Standard Pin-Out
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Start Voltage
Under Voltage Shutdown
Input Filter
Conditions
Min.
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
(Pi)
Filter
Conditions
Dual Output, Balanced Loads
V
IN
= Min to Max
I
OUT
= 0% to 100%
See Note 1
25% Load Step Change
Min.
Typ.
Max.
9.0
18.0
8.5
17.5
Units
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Overload Protection
Output Short Circuit
Typ.
±0.5
±0.3
±0.3
200
±3.0
±0.01
Max.
±2.0
±2.0
±1.0
±1.0
70
500
±5.0
±0.02
Units
%
%
%
%
mV P - P
µSec
%
%/°C
%
3.0 kV Isolation
Models
Available
Foldback
120
Continuous (Autorecovery)
Conditions
60 Seconds
500 VDC
100 kHz/1.0V
Min.
1,500
1,000
90
Standard
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Typ.
Max.
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Units
VDC
M
pF
kHz
2:1 Input Range
Models
Available
500
See Note 3
See Note 3
Level
Class A
Class A
Criteria A; ±8 kV Air ±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±1 kV
Criteria A; 10V/m
Min.
-40
Typ.
+25
Max.
+85
+100
+125
95
Units
°C
°C
°C
%
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
-50
Free Air Convection
RH, Non-condensing
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.45 Oz (12.8g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
1.0
Min.
-0.7
-0.7
Typ.
Max.
Units
MHours
Units
VDC
°C
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Typ.
Max.
50.0
100.0
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
[Xingkong Board Python Programming Learning Main Control Board] Evaluation 5: Burning System Image
[i=s]This post was last edited by Tianyiwuzui on 2022-11-13 20:30[/i]Before you start developing a board, in addition to understanding the basic knowledge of hardware architecture, you must also confi...
天意无罪 Embedded System
[Xingkong Board Python Programming Learning Control Panel] Review 6: Mind+ Programming Experience
Xingkong Board supports multiple programming methods, including: Mind+, jupyter, Thonny, SSH, etc.; Mind+ is a programming method that is strongly recommended by the official, because Mind+ supports g...
天意无罪 Embedded System
RF Integrated Balun Transformer Design
...
btty038 RF/Wirelessly
How about powering the MCU like this?
[i=s]This post was last edited by kal9623287 on 2022-11-14 09:11[/i]As shown in the figure below, if we consider the minimalist design to save cost, three diodes are connected in series, 5V power supp...
kal9623287 Power technology
I moved house and broke my computer...
I moved yesterday. I dropped my computer and the tempered glass shattered all over the floor because I didn't hold it steady. I didn't think the computer would break at the time. After arriving at the...
buildele Talking
What are the spacing requirements for drill holes in the fabrication of single-sided or double-sided PCBs?
The production of single-sided or double-sided PCBs is to drill non-conducting holes or conducting holes directly after cutting, while multi-layer boards are drilled after the pressing is completed. D...
东胜物联 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1230  1279  2385  2501  2268  25  26  49  51  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号