EEWORLDEEWORLDEEWORLD

Part Number

Search

MA612D12RW

Description
MA600RW SERIES
File Size482KB,2 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet View All

MA612D12RW Overview

MA600RW SERIES

MA600RW
Series
Wide 2:1 Input, 6W,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Key Features:
6W Output Power
2:1 Input Voltage Range
1,500 VDC Isolation
24 Standard Models
Single & Dual Outputs
Compact DIP Case
-40°C to +85°C Operation
Industry Standard Pin-Out
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Start Voltage
Under Voltage Shutdown
Input Filter
Conditions
Min.
12 VDC Input
7.0
24 VDC Input 14.0
48 VDC Input 32.0
12 VDC Input
24 VDC Input
48 VDC Input
(Pi)
Filter
Conditions
Dual Output, Balanced Loads
V
IN
= Min to Max
I
OUT
= 0% to 100%
See Note 1
Over Line, Load & Temp.
25% Load Step Change
Min.
Typ.
8.0
16.0
34.0
Max.
9.0
18.0
36.0
8.5
16.0
35.0
Units
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Typ.
±1.0
±1.0
±0.1
±0.6
Max.
±2.0
±2.0
±0.5
±1.2
70
100
600
±0.02
Units
%
%
%
%
mV P - P
µSec
%
%/°C
%
3.0 kV Isolation
Models
Available
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Overload Protection
Output Short Circuit
300
±3.0
±0.01
Foldback
110
145
Continuous (Autorecovery)
Min.
1,500
1,000
Typ.
General
4:1 Input Range
Models
Available
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Conditions
60 Seconds
500 VDC
100 kHz/1.0V
Max.
1,000
330
Units
VDC
M
pF
kHz
Standard
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
See Note 3
See Note 3
Level
Class A
Class A
Criteria A; ±8 kV Air ±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±1 kV
Criteria A; 10V/m
Min.
-40
Typ.
+25
Max.
+85
+100
+125
95
Units
°C
°C
°C
%
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
-50
Free Air Convection
RH, Non-condensing
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.45 Oz (12.8g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
1.0
Min.
-0.7
-0.7
-0.7
Typ.
Max.
Units
MHours
Units
VDC
°C
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Typ.
Max.
25.0
50.0
100.0
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2495  1696  1884  2749  51  51  35  38  56  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号