EEWORLDEEWORLDEEWORLD

Part Number

Search

B1517ERU

Description
B1500ERU SERIES
File Size247KB,2 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet View All

B1517ERU Overview

B1500ERU SERIES

B1500ERU
Series
Ultra-Wide Input 15W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
15W Output Power
4:1 Input Voltage Range
1,500 VDC Isolation
Compact 1 x 2 Inch Case
Single & Dual Outputs
Remote ON/OFF
Industry Standard Pin-Out
Input
Parameter
Input Start Voltage
Input Filter
Start-Up Time
Conditions
24 VDC Input
48 VDC Input
(Pi) Filter
10
Conditions
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
55
120
25% Load Step Change
200
±3.0
±0.01
Continuous (Autorecovery)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
1,000
300
Conditions
Ambient
Min.
-40
-55
RH, Non-condensing
Six-Side Shielded Metal Case
2.0 x 1.0 x 0.43 Inches (50.8 x 25.4 x 11.0 mm)
Metal with Non-Conductive Base
1.13 Oz (32g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
700
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
300.0
Typ.
Max.
Units
kHours
Units
VDC
°C
Typ.
+25
Max.
+85
+105
95
Typ.
Max.
Units
VDC
M
pF
kHz
Units
°C
°C
%
Min.
Typ.
±1.0
±0.5
±0.2
±0.5
75
±0.5
±1.0
±5.0
150
150
300
±5.0
±0.02
Max.
±2.0
mS
Units
%
%
%
%
%
mV P - P
%
µSec
%
%/°C
Min.
Typ.
8.8
17.8
Max.
9.0
18.0
Units
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Cross Regulation
Ripple & Noise (20 MHz) (Note 1)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
RFI
Physical
Free Air Convection (See Curves on Page 2)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 246  1118  776  2918  1978  5  23  16  59  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号