To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages A-53 thru A-61. For additional options not shown in catalog, consult Customer Service Center. All
models have epoxy terminal seal and are compatible with all “bottom-wash” PCB cleaning methods.
Switch Function
8161
SPDT On-On
8168
SPDT On-Mom.
8261
DPDT On-On
Actuator or Plunger
S
.710"
high plunger
with .375" dia. cap
J80
Snap-in
J81
Snap-in with frame
J82
Snap-in with frame for LED
J86
Snap-in with frame & LED
L
.740" high plunger with
.395" dia. cap
L1
.740" high plunger with
.590" dia. cap
S1
.615" high plunger with
.200" dia. cap
S2
.710" high plunger with
.310" dia. cap
Bushing
H
.300" high, flat, hi torque
H9
.300" high, flat, hi torque
NONE
No bushing choice required
Y3
7.6mm, keyway
Terminations
A
Right angle, PC thru-hole
AV2
Vertical right angle,
PC thru-hole
C
PC Thru-hole
Z
Solder lug
A3
Right angle, snap-in, PC thru-hole
AV3
Vertical right angle, snap-in,
PC thru-hole
V3
.460" high, V-bracket
V4
.630" high, V-bracket
V6
.460" high, V-bracket
V21
.555" high, snap-in V-bracket
V31
.460" high, snap-in V-bracket
W
.750" long, wire wrap
Z3
Quick connect
Contact Material
B
Gold
P
Gold, matte-tin
Q
Silver
S
Silver, matte-tin
G
Gold over silver
R
Gold over silver,
matte-tin
Seal
E
Epoxy
I
Epoxy potted base
Cap Color
2
Black
1
White
3
Red
4
Orange
5
Yellow
9
Gray
Frame Color
2
Black
LED Color
3
Red
NONE
Models without LED
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–52
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
SWITCH FUNCTION
SWITCH FUNCTION
POS. 1
POS. 2
CONNECTED TERMINALS
POS. 1
POS. 2
A
Pushbutton
NO.
POLES
MODEL NO.
C&K marking this side
C&K marking this side
SCHEMATIC
SP
8161
8168
ON
ON
ON
MOM.
2-3
2-3
2-1
2-1
SPDT
SPDT
Part number shown: 8161SHZQE
Terminal Nos.
For Reference Only
DP
8261
ON
ON
2-3,5-6
2-1,5-4
DPDT
DPDT
Part number shown: 8261SHZQE
MOM. = Momentary
All models
Terminal Nos.
For Reference Only
with all options when ordered with G, L, M or Q contact material.
CAP COLOR
ACTUATOR—SNAP-IN FRONT MOUNT
ACTUATOR OR PLUNGER
J80
SNAP-IN
PANEL MOUNTING
OPTION
CODE
*
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
*Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,41/2,18)
thick panels.
2
1
3
4
5
9
Cap Finish: matte.
Other colors available, consult
Customer Service Center.
Available with C, W, Z or
Z3 terminations.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
J81
SNAP-IN WITH BLACK FRAME
PANEL MOUNTING
*
*Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,41/2,18)
thick panels.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–53
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
CAP COLOR
A
Pushbutton
J82
ACTUATOR—SNAP-IN FRONT MOUNT
ACTUATOR OR PLUNGER
SNAP-IN WITH BLACK FRAME FOR LED
Available with C, W, Z or Z3 terminations.
LED not included.
For LED information, see page A-61.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
Other colors available, consult
Customer Service Center.
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
2
1
3
4
5
9
CAP COLOR
LED COLOR
ACTUATOR—SNAP-IN FRONT MOUNT
J86
SNAP-IN WITH BLACK FRAME AND LED
ACTUATOR OR PLUNGER
PANEL MOUNTING
*
8161J86ZQE223
SPDT
Available with C, W, Z or Z3 terminations and SPDT models only.
* Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,31/3,18)
thick panels.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
Other colors available, consult
Customer Service Center.
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
OPTION
CODE
LED COLOR
RED
2
1
3
4
5
9
3
For LED information, see page A-59.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–54
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
CAP COLOR
PLUNGER
ACTUATOR OR PLUNGER
A
Pushbutton
PLUNGER WITH CAP P/N 8018
S
PLUNGER WITH CAP P/N 7527
S1
PLUNGER WITH CAP P/N 7089
S2
L
PLUNGER WITH CAP P/N 8941
L1
PLUNGER WITH CAP P/N 8940
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
2
1
3
4
5
9
Cap Finish: gloss. Cap supplied not installed.
Other colors available, consult Customer
Service Center.
NOTE:
When selecting plunger and cap option, bushing selection must also be made, see below.
BUSHING
H
H9
.300" HIGH THREADED, FLAT
.300" HIGH UNTHREADED, FLAT
NONE
NO BUSHING CHOICE REQUIRED
(JXX ACTUATORS)
Y3
7.6mm THREADED, KEYWAY
1/4±40 UNS-2A
H bushing standard with C, W, Z or Z3 terminations.
H9 bushing standard with A, A3, AV2, AV3, or
V3-V31 terminations.
Withstands 12 in./lbs. of torque with no distortion.
Withstands 12 in./lbs. of torque with no distortion.
NOTE:
When selecting bushing option, plunger selection must also be made, see above. No bushing option choice required when any JXX actuator option is selected.
NOTE.
Two mounting nuts, locking ring and lockwasher supplied standard with threaded bushings.
Optional mounting nut and locking ring styles and finishes available, see section “Technical Data and
Additional Hardware”.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–55
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
A
Pushbutton
C
PC THRU-HOLE
PC MOUNTING
TERMINATIONS
Z
SOLDER LUG
SPDT and DPDT
SPDT and DPDT
Not available with P, S or R contact material.
Z3
QUICK CONNECT
W
WIRE WRAP
.750
(19,05)
SPDT and DPDT
Not available with P, S or R contact material.
Mating quick connector available;
order part number 530100000, page A-61.
SPDT and DPDT
A
HOLE
RIGHT ANGLE, PC THRU-
.130
(3,3)
.138
(3,51)
8161SH9ABE2
SPDT
SECTION A-A
A3
RIGHT ANGLE, SNAP-IN, PC THRU-HOLE
PC MOUNTING
Not available with I seal.
Terminal bend radii and lead-in manufacturing option.
EX02 realizes the function of displaying the key input on the digital tube, and EX03 realizes the function of the serial port. The next step is to integrate the functions of EX02 and EX03, and send th...
The SIMILINK module library is divided into the following 8 sub-libraries according to its function: Continuous (continuous module) Discrete (discrete module) Function&Tables (function and platform mo...
I saw a lot of new things at the event today, and felt a new trend. Although integrated with NXP, FreeScale still exhibited a lot of products. There are also MediaTek products...
In 4 transmitting terminals, for one receiving terminal, the transmitting terminal actively sends once every 10 seconds. After being powered on, the transmitting terminals will send data at the same t...
Reflow soldering, a common soldering method in modern electronics manufacturing, primarily melts solder paste and pads to form solder joints. With technological advancements, soldering equipment ha...[Details]
White light LEDs are voltage-sensitive devices. In actual operation, their upper limit is 20mA. However, the current often increases due to various reasons during use. If no protective measures are...[Details]
The Automotive Testing and Quality Assurance Expo (ATE 2025) will open on August 27th. At the expo, Rohde & Schwarz (R&S) will showcase six automotive testing solutions, themed "Intelligently Drivi...[Details]
introduction
Sonar imaging is of great significance in marine resource development and defense. Its long range, intuitive display of the observed area, and target identification make it widely...[Details]
Have you ever heard stories about "crazy appliances"? Think of microwaves that turn on automatically or ovens that preheat without any human input? With radios and electromagnetic interfaces ubiqui...[Details]
Overview
As handheld voice communication devices become more and more popular, they are increasingly used in noisy environments, such as airports, busy roads, crowded bars, etc. In such noisy ...[Details]
The complexity of the integrated circuits (ICs) used in electronic systems in vehicles is increasing. They aim to execute artificial intelligence (AI) algorithms to control autonomous driving funct...[Details]
Keysight Technologies is combining its electromagnetic simulator with Synopsys' AI-driven RF design migration flow to create an integrated design flow for migrating from TSMC's N6RF+ process techno...[Details]
Plessey Semiconductors has been acquired by Haylo Labs, which was established in March last year with a $100 million, five-year loan from Chinese technology company Goertek.
Haylo Labs w...[Details]
Intel®
Xeon®
6
-
core processors now support the new Amazon EC2 R8i and R8i-flex instances on Amazon Web Services (AWS).
These new instances offer superior performance and fast...[Details]
Introduction: In digital circuit calculations, there is no concept of decimal points. You know where the decimal is, but the circuit does not know where the decimal point is. Therefore, you need to...[Details]
summary
Modern cars strive to provide the same comfort and entertainment features found in the home, resulting in explosive growth in demand for electronic control units (ECUs). Howe...[Details]
Driven by business opportunities such as access to new markets and government initiatives like the Belt and Road Initiative, global expansion has become a significant trend for Chinese companies. C...[Details]
Keysight Technologies reported strong third-quarter results, with revenue and earnings per share exceeding expectations and steady order growth. The company, driven by strong growth across multiple...[Details]
Generally not, but there are exceptions. For example, a torque motor controller with three-phase output voltage imbalance can cause current imbalance, similar to a phase loss. However, only two pha...[Details]