To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages A-53 thru A-61. For additional options not shown in catalog, consult Customer Service Center. All
models have epoxy terminal seal and are compatible with all “bottom-wash” PCB cleaning methods.
Switch Function
8161
SPDT On-On
8168
SPDT On-Mom.
8261
DPDT On-On
Actuator or Plunger
S
.710"
high plunger
with .375" dia. cap
J80
Snap-in
J81
Snap-in with frame
J82
Snap-in with frame for LED
J86
Snap-in with frame & LED
L
.740" high plunger with
.395" dia. cap
L1
.740" high plunger with
.590" dia. cap
S1
.615" high plunger with
.200" dia. cap
S2
.710" high plunger with
.310" dia. cap
Bushing
H
.300" high, flat, hi torque
H9
.300" high, flat, hi torque
NONE
No bushing choice required
Y3
7.6mm, keyway
Terminations
A
Right angle, PC thru-hole
AV2
Vertical right angle,
PC thru-hole
C
PC Thru-hole
Z
Solder lug
A3
Right angle, snap-in, PC thru-hole
AV3
Vertical right angle, snap-in,
PC thru-hole
V3
.460" high, V-bracket
V4
.630" high, V-bracket
V6
.460" high, V-bracket
V21
.555" high, snap-in V-bracket
V31
.460" high, snap-in V-bracket
W
.750" long, wire wrap
Z3
Quick connect
Contact Material
B
Gold
P
Gold, matte-tin
Q
Silver
S
Silver, matte-tin
G
Gold over silver
R
Gold over silver,
matte-tin
Seal
E
Epoxy
I
Epoxy potted base
Cap Color
2
Black
1
White
3
Red
4
Orange
5
Yellow
9
Gray
Frame Color
2
Black
LED Color
3
Red
NONE
Models without LED
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–52
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
SWITCH FUNCTION
SWITCH FUNCTION
POS. 1
POS. 2
CONNECTED TERMINALS
POS. 1
POS. 2
A
Pushbutton
NO.
POLES
MODEL NO.
C&K marking this side
C&K marking this side
SCHEMATIC
SP
8161
8168
ON
ON
ON
MOM.
2-3
2-3
2-1
2-1
SPDT
SPDT
Part number shown: 8161SHZQE
Terminal Nos.
For Reference Only
DP
8261
ON
ON
2-3,5-6
2-1,5-4
DPDT
DPDT
Part number shown: 8261SHZQE
MOM. = Momentary
All models
Terminal Nos.
For Reference Only
with all options when ordered with G, L, M or Q contact material.
CAP COLOR
ACTUATOR—SNAP-IN FRONT MOUNT
ACTUATOR OR PLUNGER
J80
SNAP-IN
PANEL MOUNTING
OPTION
CODE
*
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
*Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,41/2,18)
thick panels.
2
1
3
4
5
9
Cap Finish: matte.
Other colors available, consult
Customer Service Center.
Available with C, W, Z or
Z3 terminations.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
J81
SNAP-IN WITH BLACK FRAME
PANEL MOUNTING
*
*Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,41/2,18)
thick panels.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–53
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
CAP COLOR
A
Pushbutton
J82
ACTUATOR—SNAP-IN FRONT MOUNT
ACTUATOR OR PLUNGER
SNAP-IN WITH BLACK FRAME FOR LED
Available with C, W, Z or Z3 terminations.
LED not included.
For LED information, see page A-61.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
Other colors available, consult
Customer Service Center.
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
2
1
3
4
5
9
CAP COLOR
LED COLOR
ACTUATOR—SNAP-IN FRONT MOUNT
J86
SNAP-IN WITH BLACK FRAME AND LED
ACTUATOR OR PLUNGER
PANEL MOUNTING
*
8161J86ZQE223
SPDT
Available with C, W, Z or Z3 terminations and SPDT models only.
* Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,31/3,18)
thick panels.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
Other colors available, consult
Customer Service Center.
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
OPTION
CODE
LED COLOR
RED
2
1
3
4
5
9
3
For LED information, see page A-59.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–54
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
CAP COLOR
PLUNGER
ACTUATOR OR PLUNGER
A
Pushbutton
PLUNGER WITH CAP P/N 8018
S
PLUNGER WITH CAP P/N 7527
S1
PLUNGER WITH CAP P/N 7089
S2
L
PLUNGER WITH CAP P/N 8941
L1
PLUNGER WITH CAP P/N 8940
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
2
1
3
4
5
9
Cap Finish: gloss. Cap supplied not installed.
Other colors available, consult Customer
Service Center.
NOTE:
When selecting plunger and cap option, bushing selection must also be made, see below.
BUSHING
H
H9
.300" HIGH THREADED, FLAT
.300" HIGH UNTHREADED, FLAT
NONE
NO BUSHING CHOICE REQUIRED
(JXX ACTUATORS)
Y3
7.6mm THREADED, KEYWAY
1/4±40 UNS-2A
H bushing standard with C, W, Z or Z3 terminations.
H9 bushing standard with A, A3, AV2, AV3, or
V3-V31 terminations.
Withstands 12 in./lbs. of torque with no distortion.
Withstands 12 in./lbs. of torque with no distortion.
NOTE:
When selecting bushing option, plunger selection must also be made, see above. No bushing option choice required when any JXX actuator option is selected.
NOTE.
Two mounting nuts, locking ring and lockwasher supplied standard with threaded bushings.
Optional mounting nut and locking ring styles and finishes available, see section “Technical Data and
Additional Hardware”.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–55
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
A
Pushbutton
C
PC THRU-HOLE
PC MOUNTING
TERMINATIONS
Z
SOLDER LUG
SPDT and DPDT
SPDT and DPDT
Not available with P, S or R contact material.
Z3
QUICK CONNECT
W
WIRE WRAP
.750
(19,05)
SPDT and DPDT
Not available with P, S or R contact material.
Mating quick connector available;
order part number 530100000, page A-61.
SPDT and DPDT
A
HOLE
RIGHT ANGLE, PC THRU-
.130
(3,3)
.138
(3,51)
8161SH9ABE2
SPDT
SECTION A-A
A3
RIGHT ANGLE, SNAP-IN, PC THRU-HOLE
PC MOUNTING
Not available with I seal.
Terminal bend radii and lead-in manufacturing option.
Ah, Children's Day is coming, playful forum friends, come and have some fun. I would like to use this article to commemorate my lost childhood. :hug:...
ADC1 6 channels, DMA transfer. Timer 2 measures external interrupt frequency.When DMA is turned on, the measured external interrupt frequency has a large error. When it is turned off, it is normal.Can...
Atmel SAM4L picoPower Introduction : https://training.eeworld.com.cn/course/29SAM4L sets a new benchmark for low power consumption with the world's most efficient Cortex-M4 core. There are many reason...
When purchasing energy consumption metering instruments, the company has learned that most of them use the m-bus protocol. I want to know whether the m-bus protocol can communicate on the 485 bus. If ...
Figure 1
Once powered on normally, the chip Vref has a 5V reference voltage, which generates base current through r1, turns on transistor Q1, and generates collector current flowing through r2.
Howeve...
Human body information monitoring is an emerging field. People envision developing wireless electroencephalogram (EEG) monitoring equipment to diagnose epilepsy patients. Wearable wireless EEG can ...[Details]
Keeping the heart environment compact and warm is beneficial in most cases, but it’s another story for electronic heart scanners. When GE Healthcare was designing a scanner that was said to be the fas...[Details]
As a single-host multi-slave bus system, the number of slave devices that can be connected to a 1-Wire bus is almost unlimited. In order to avoid logical conflicts, the 1-Wire bus interfaces of all...[Details]
The hardware circuit principle is shown in Figure 1. In the specific design, each part should consider the anti-interference problem to minimize the impact of interference on the performance of the...[Details]
As the price of readers and tags decreases and the global market expands, the application of radio frequency identification (RFID) is increasing day by day. Tags can be powered by readers (passive ...[Details]
Abstract: Based on the research of the communication process between the reader and the RFID tag, combined with the EPC C1G2 protocol and ISO/IEC18000.6 protocol, a digital circuit of RFID tag appl...[Details]
Complex circuits and 3D EM simulation tools have reached a point where complex system-level behavior can be simulated before fabrication. Performing EM simulations simultaneously with circuit simul...[Details]
summary
Theoretically explains how to set up a PFC boost regulator using a current sensing transformer with the UCC3817 control IC.
1. Schematic
The schematic diagram is show...[Details]
A well-designed electronic load is not designed just for use in the lab; it should be carefully designed and built to test actual power systems. This is true for military portable systems, such as ...[Details]
1. Introduction
The UCC28051 reference design is a 100W offline AC/DC voltage converter with power factor correction (PFC). This power module design is intended to illustrate how to proper...[Details]
introduction
In engineering practice, ultrasonic waves are often used to measure distances because of their strong directivity, slow energy consumption, and long propagation distance in th...[Details]
Electrocardiogram is an important means of diagnosing heart disease. However, due to various reasons, it is difficult to capture abnormal electrocardiograms with ordinary electrocardiographs. Although...[Details]
1 Introduction
Intelligent software agents are software programs that can perform specific tasks for users, have a certain degree of intelligence, can autonomously perform some tasks, and ...[Details]
Abstract:
Under high dynamic conditions, combined with GEC's twelve-channel correlator GP2021, this paper discusses the structural design of GPS receivers and the key technologies inv...[Details]
Abstract: In many SCART applications, due to the complex signal switching requirements, dedicated ICs are usually used to implement SCART connections. This will bring cost pressure to single SCART ...[Details]