SIOY2L1V2
Current Sensors
Features
Hall effect measuring principle
Galvanic isolation between primary and
secondary circuit
Compact design for PCB mounting
Low power consumption
Extended measuring range (3 *I
PN
)
Insulated plastic case recognized according
to UL 94-V0
I
PN
= 50…600A V
OUT
= ± 4 V
Advantages
Easy installation
Excellent accuracy
No insertion losses
Excellent performance and price
Only one design for wide current ratings
range
High immunity against external
interference
Industrial applications
AC variable speed drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding applications
Static converters for DC motor drives
Switched-Mode Power Supplies (SMPS)
Type
SIOY2L150V2
SIOY2 L175V2
SIOY2 L1100V2
SIOY2 L1150V2
SIOY2 L1200V2
SIOY2 L1300V2
SIOY2 L1400V2
SIOY2 L1500V2
SIOY2 L1600V2
TYPES OF PRODUCTS
Primary nominal current
Primary current measuring range
r. m. s I
PN
(A)
I
P
(A)
50
75
100
150
200
300
400
500
600
±150
±225
±300
±450
±600
±900
±900
±900
±900
General Description
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between
the primary circuit and the secondary circuit.
1
V2.00 May 1, 2012
SIOY2L1V2
Current Sensors
Parameters Table
PARAMETERS
Supply voltage(±5%)
(1)
Current consumption
Output voltage
Overload capability(1ms)
Isolation resistance
Output internal resistance
Load resistance
(2)
R. m. s voltage for AC
isolation test
R. m. s rated voltage、safe
separation
Linearity
(3)
(0…±I
PN
)
Accuracy
Electrical offset voltage
Hysteresis offset voltage
Temperature coefficient of V
OE
Temperature coefficient of
V
OUT
Response time
d
i
/d
t
accurately followed
Frequency bandwidth
(4)
Ambient operating temperature
Ambient storage temperature
Mass
SYMBOL
V
C
I
C
V
out
I
PC
R
IS
R
OUT
R
L
V
d
V
b
UNIT
Electrical data
V
mA
mV
At
MΩ
Ω
KΩ
KV
V
±15
±15
±4V±40
50*I
PN
>1000
100
>
10
VALUE
CONDITIONS
@ ± I
PN
, R
L
= 10 kΩ,
T
A
= 25°C
@ 500 VDC
approx
3
500
@50, 1 min
Accuracy - Dynamic performance data
ε
L
X
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
d
i
/d
t
BW
T
A
T
S
m
% of I
PN
% of I
PN
mV
mV
mV/K
%/K
μS
A/μS
kHz
General data
°C
°C
g
-20 ~ +85
-40 ~ +105
approx 60
<±1
<±1
<±20
<±20
<±2
<±1
<±0.1
<3
>50
DC~50
@-3dB
@ I
PN
, T
A
= 25°C
(excluding offset)
@T
A
= 25°C
@ I
P
= 0
after an excursion of 1* I
PN
@SIOY2L150-75V2
@SIOY2L1100-600V2
@% of reading
@ 90% of I
PN
step
Notes:
1.
2.
3.
4.
Operating at
±12V
≤VC<±15V
will reduce the measuring range.
If the customer uses 1 KΩ of the load resistor, the primary current has to be limited as the
nominal. To measure the full defined measuring range, the load resistor should be at minimum 10
KΩ.
Linearity data exclude the electrical offset.
Please refer to derating curves in the technical file to avoid excessive core heating at high
frequency.
2
V2.00 May 1, 2012
SIOY2L1V2
Current Sensors
Dimensions SIOY2L1V2
(
in mm. 1 mm = 0.0394 inch
)
Instructions of use
1.
When the test current passes through the sensors you can get the size of the output
voltage.(Warning: wrong connection may lead to sensors damage)
Based on user needs, the sensors output range can be appropriately regulated.
According to user needs, different rated input currents and output voltages of the sensors can be
customized.
2.
3.
3
V2.00 May 1, 2012
SIOY2L1V2
Current Sensors
RESTRICTIONS ON PRODUCT USE
1.
2.
The information contained herein is subject to change without notice.
SEC ELECTRONICS INC. (for short SEC) exerts the greatest possible effort to ensure high
quality and reliability. Nevertheless, semiconductor devices in general can malfunction or fail due
to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of
the buyer, when utilizing SEC products, to comply with the standards of safety in making a safe
design for the entire system, including redundancy, fire-prevention measures, and malfunction
prevention, to prevent any accidents, fires, or community damage that may ensue. In developing
your designs, please ensure that SEC products are used within specified operating ranges as set
forth in the most recent SEC products specifications.
The SEC products listed in this document are intended for usage in general electronics
applications (computer, personal equipment, office equipment, measuring equipment, industrial
robotics, domestic appliances, etc.). These SEC products are neither intended nor warranted for
usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or
failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended
Usage include atomic energy control instruments, airplane or spaceship instruments, transportation
instruments, traffic signal instruments, combustion control instruments, medical instruments, all
types of safety devices, etc.. Unintended Usage of SEC products listed in this document shall be
made at the customer’s own risk.
3.
4
V2.00 May 1, 2012