8450 Paired - Single-Pair Cable
For more information please
call
1-800-Belden1
See Put-ups and Colors
Color Code Chart : No. 3 for
Paired Cables (Belden
Standard).pdf
Description:
22 AWG solid tinned copper conductors, polypropylene insulation, twisted pair, overall Beldfoil shield (100% coverage), 22 AWG solid TC
drain wire, PVC jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Pairs
Total Number of Conductors
AWG
Stranding
Conductor Material
INSULATION:
Insulation Material
Nom. Insulation Wall Thickness
Pair Color Code Chart :
Number
1
OUTER SHIELD:
Outer Shield Material Trade Name
Outer Shield Type
Outer Shield Material
Outer Shield %Coverage
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG
Outer Shield Drain Wire Stranding
Outer Shield Drain Wire Conductor Material
OUTER JACKET:
Page 1 of 3
1
2
22
Solid
TC - Tinned Copper
PP - Polypropylene
.007 in.
Color
Black & Red
Beldfoil® (Z-Fold®)
Tape
Aluminum Foil-Polyester Tape
100 %
22
Solid
TC - Tinned Copper
8450 Paired - Single-Pair Cable
Outer Jacket Material
Outer Jacket Nominal Wall Thickness
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
UL Temperature Rating
Bulk Cable Weight
Max. Recommended Pulling Tension
Min. Bend Radius (Install)
PVC - Polyvinyl Chloride
.018 in.
.118 in.
-20°C To +105°C
75°C
12.2 lbs/1000 ft.
37 lbs.
1.2 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CEC/C(UL) Specification
EU CE Mark (Y/N)
EU RoHS Compliant (Y/N)
EU RoHS Compliance Date (mm/dd/yyyy):
FLAME TEST:
UL Flame Test
PLENUM/NON-PLENUM:
Plenum (Y/N)
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance
Nom. Inductance
Nom. Capacitance Conductor to Conductor @ 1 KHz
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz
Nominal Velocity of Propagation
Nominal Delay
Nom. Conductor DC Resistance @ 20 Deg. C
Nominal Outer Shield DC Resistance @ 20 Deg. C
Max. Operating Voltage - UL
Max. Recommended Current
NOTES:
Notes
Belden's® Miniature Type Broadcast Audio and Instrumentation Cables occupy 1/2
to 2/3 less space than standard cables.
Page 2 of 3
CM
CM
Yes
Yes
01/01/2004
UL1685 UL Loading
N
40 Ohms
0.08 µH/ft
40 pF/ft
76 pF/ft
66 %
1.5 ns/ft
16.1 Ohms/1000 ft
12.65 Ohms/1000 ft
300 V RMS
2.9 Amps per conductor @ 25°C
8450 Paired - Single-Pair Cable
PUT-UPS AND COLORS:
Item
Description
8450 0081000
2 #22 PP SHLD PVC
FR
8450 0101000
2 #22 PP SHLD PVC
FR
8450 010U1000
2 #22 PP SHLD PVC
FR
8450 010U500
2 #22 PP SHLD PVC
FR
Revision Number: 1
Put-Up (ft.)
1000
1000
U1000
U500
Ship Weight (lbs.)
13
13
14
7.5
Jacket Color
GRAY
BLACK
BLACK
BLACK
Notes
Revision Date: 07-27-2005
© 2005 Belden Wire & Cable Company
All Rights Reserved.
Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication,
information and specifications described herein are subject to error or omission and to change without notice, and the listing of such
information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California
Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS
(Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our
Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR
(Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as
reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its
publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any
other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality
specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of
legislation and regulations based on their individual usage of the product.
Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended
by directive 93/68/EEC.
Page 3 of 3