RF AMPLIFIER
MODEL
TM6519PM
Features
!
!
!
!
Superior Phase Noise Performance
Output Power: +19 dBm Typical
High Third Order Intercept: +34 dBm Typical
Operating Temp. -55 ºC to +85 ºC
TYPICAL
Ta= 25 ºC
10 - 500 MHz
14.3
+19
-16
<1.5:1
<1.6:1
<5.5
+15
70
MIN/MAX
Ta = -55 ºC to +85 ºC
10 - 500 MHz
12.0 Min.
+17 Min.
-15 Max.
2.0:1 Max.
2.0:1 Max.
6.0 Max.
+15
73 Max.
Available as:
TM6519PM, 4 Pin TO-8 (T4)
TN6519PM, 4 Pin Surface Mount (SM3)
FP6519PM, 4 Pin Flatpack (FP4)
BX6519PM, Connectorized Housing (H1)
Typical Intermodulation Performance at 25 ºC
Second Order Harmonic Intercept Point ....... +45 dBm (Typ.)
Second Order Two Tone Intercept Point ........ +40 dBm (Typ.)
Third Order Two Tone Intercept Point ............ +34 dBm (Typ.)
Maximum Ratings
Ambient Operating Temperature ................ -55ºC to +100 ºC
Storage Temperature ................................. -62ºC to +125 ºC
Case Temperature .................................................. +125 ºC
DC Voltage .......................................................... +18 Volts
Continuous RF Input Power .................................. +13 dBm
Short Term RF Input Power ...... 50 Milliwatts (1 Minute Max.)
Maximum Peak Power .................... 0.2 Watt (3
µsec
Max.)
Guaranteed Phase Noise Performance
(dBc/Hz)
Frequency
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
Typical
-155
-165
-166
-170
-170
Guarantee (Min.)
-151
-161
-162
-166
-166
Specifications
CHARACTERISTIC
Frequency
Gain (dB)
Power @ 1 dB
Comp. (dBm)
Reverse
Isolation (dB)
VSWR
In
Out
Noise Figure (dB)
Power
Vdc
mA
Note: Care should always be taken to effectively ground the case of each unit.
Typical Performance Data
Gain (dB)
16
15
14
13
12
Start 10 MHz
Stop 500 MHz
0
- 5
-10
-15
-20
Reverse Isolation (dB)
-130
-140
-150
-160
Start 10 MHz
Stop 500 MHz
Phase Noise (dBc/Hz)
1 dB Comp. (dBm)
+21
+20
+19
+18
+17
Start 10 MHz
Noise Figure (dB)
7
6
5
4
3
-170
-180
-190
100
1K
10K
100K
1M
_________Guarantee __ __ __ __Typical
Start 10 MHz
2.0
1.5
1.0
Start 10 MHz
Input VSWR
Stop 500 MHz
2.0
1.5
1.0
Stop 500 MHz
Start 10 MHz
Output VSWR
Stop 500 MHz
Phase Noise Test Conditions:
Carrier Frequency: 200 MHz
Power Output: +19 dBm
Temperature: 25 ºC
Agilent ES5500 System
Stop 500 MHz
Legend
+25 ºC
+85 ºC - - - - - - -55 ºC
Linear S-Parameters
S11
S21
S12
S22
FREQ.
MHz
Mag.
Deg.
Mag.
Deg.
Mag.
Deg.
Mag.
Deg.
========================================================================================
5
10
50
100
200
300
400
500
.17
.12
.09
.09
.07
.06
.07
.08
-109
-135
-179
168
119
73
17
- 30
5.21
5.33
5.39
5.39
5.40
5.39
5.38
5.34
-164
-174
172
162
142
122
102
82
.11
.11
.12
.12
.12
.13
.14
.15
18
9
1
- 1
- 4
- 9
- 15
- 22
.22
.13
.09
.08
.07
.07
.07
.08
135
139
160
156
150
138
133
121
Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, Florida 32905 · PH (888) 553-7531 · Fax (888) 553-7532
3/31/04
www.SpectrumMicrowave.com
Spectrum Microwave · 2707 Black Lake Place · Philadelphia, Pennsylvania 19154 · PH (215) 464-4000 · Fax (215) 464-4001