Thermal Overcurrent Circuit Breaker 1410-L/-G

Thermal Overcurrent Circuit Breaker 1410-L/-G...
Description
Single pole press-to-reset thermal circuit breaker with extremely fast
overload switching performance (R-type TO CBE to EN 60934). Single
hole threadneck, PCB or integral mounting with a choice of designs.
Miniaturised construction minimises PCB real estate required. Type
1410-L2 and 1410-G1 versions feature changeover contacts suitable
for providing status output signals. Largely temperature-insensitive.
Typical applications
Motors, transformers, solenoids, PCBs, hand-held machines, ap-
pliances, instrumentation.
1
1410-L1...
Ordering information
Type No.
1410
single pole circuit breaker
Configuration
L PCB mounting
G threadneck panel mounting
Mounting
1 threadneck 3/8-27 UNS-2A (1410-G)
1 PCB 16.3x4.6 grid (1410-L)
2 PCB 10.15x7.62 grid (1410-L)
Number of poles
1 1 pole, thermally protected
Hardware
0
without
1
with hex nut and knurled nut (1410-G only) bulk shipped
Terminal design
L1 solder pins 1.8x0.8 silver-plated (-L1 only)
L2 solder pins 1x0.8 silver-plated (-L2 and -G1 only)
P2 blade terminals A2.8-0.8 silver-plated (-G1 only)
Characteristic curve
F1
fast acting
Actuator
S manual re-set
Actuator colour
01 black (for -G1.. and -L1..)
02 white (for -L2..)
Current ratings
0.63 ... 10 A
1410-
L 1 1
0 - L1
F1 - S 01 - 0.8 A
ordering example
1410-L2...
1410-G1...
Technical data
Voltage rating
Current rating range 1-2
Auxiliary circuit 1-3
Typical life
Ambient temperature
Insulation co-ordination
(IEC 664 and 664 A)
AC 240 V; DC 28 V (DC 50 V UL/CSA)
0.63...10 A
0.2 x I
N
max. 1 A, AC 250 V
style -L2 and -G1 only
300 operations at 2 x I
N
(-L2...)
500 operations at 2 x I
N
(-L1../-G1..)
-20...+100
°C
Rated impulse
Pollution
withstand voltage degree
2.5 kV
2
reinforced insulation in operating area
Test voltage
AC 1,500 V
> 100 MΩ (DC 500 V)
0.63...2 A 12 x I
N
2.5 ...8 A
8 x I
N
, AC max. 50 A
10 A
6 x I
N
, AC
3.15...10 A 10 x I
N
, DC
0.63...10 A
2,000 A AC 250 V
0.63... 8 A
200 A DC 50 V
operating area IP 40
terminal area IP 00
8 g (57-500 Hz)
±0.61
mm (10-57 Hz),
to IEC 68-2-6, Test Fc,
10 frequency cycles/axis
20 g (11 ms)
to IEC 68-2-27, test Ea
48 hours at 5 % salt mist,
to IEC 68-2-11, test Ka
96 hours at 95 % RH
to IEC 68-2-3, test Ca
approx. 5 g
Dielectric strength
(IEC 664 and 664A)
operating area
Insulation resistance
Interrupting capacity I
cn
(o-o-o)
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 529/DIN 40050)
Vibration
Please enquire for packaging quantities.
Shock
Corrosion
Standard current ratings and typical internal resistance values
Current
rating (A)
0.63
0.8
1
1.25
1.5
1.8
2
2.5
Internal
resistance (Ω)
1.8
1.7
1.3
<1
<1
<1
<1
< 0.15
Current
rating (A)
3.15
4
4.5
5
6.3
8
10
Internal
resistance (Ω)
< 0.12
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
Humidity
Mass
Approvals
Authority
VDE
UL, CSA
Voltage rating
AC 250 V; DC 28 V
AC 250 V; DC 50 V
Current ratings
0.63... 8 A
0.63...10 A
Issue E
¤
Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
55

1410-L210-L2F1-S02 Related Products

1410-L210-L2F1-S02 1410-G111-L2F1-S01 1410-G111-P2F1-S01 1410-L110-L1F1-S01 1410-L210-L2F1-S02-5A
Description Thermal Overcurrent Circuit Breaker 1410-L/-G Thermal Overcurrent Circuit Breaker 1410-L/-G Thermal Overcurrent Circuit Breaker 1410-L/-G Thermal Overcurrent Circuit Breaker 1410-L/-G Thermal Overcurrent Circuit Breaker 1410-L/-G
What are the communication methods between multiple tasks or threads?
What are the ways to communicate between multiple tasks or threads?...
wcqu2005 Embedded System
Simple TFTP Configuration
[table=98%][tr][td][img]http://imgcache.qq.com/ac/b.gif[/img] [img]http://imgcache.qq.com/ac/b.gif[/img] [size=16px]It is actually very easy to configure a tftp server under Redhat Linux. Let's take R...
jxb01033016 Embedded System
For emergency call systems, which battery is better, lithium iron phosphate or lithium-ion?
Reprinted from: deyisupport [align=left][color=#000]The European Parliament's eCall regulatory law was passed in 2015 and took effect in April 2018, requiring all cars released on the European market ...
okhxyyo Analogue and Mixed Signal
virtualcoy and dma
In WinCE, a RAM space is reserved as a DMA send buffer. The application writes data into it and DMA reads data. The question is whether the application and the driver can use VirtualCopy to bind the s...
xrlabc Embedded System
Share FPGA tutorial for beginners (alter)
Alter company's supporting teaching materials, I hope it will be useful to everyone! ! ! !...
yingang FPGA/CPLD
MSP430F4152 drives LCD too dark, help
[size=5]MSP430F4152 drives segment LCD, and the LCD display is dim. I have tried using both external voltage pump and internal voltage pump, and the LCD is very dim. I don't know why, can you help me ...
眼大5子 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1781  1528  1647  731  2293  36  31  34  15  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号