Free MLCSoft® for SPICE & S-Parameter Modeling Data
A
PPLICATIONS
• Cellular Products
• Cable Components
• RF Transceivers
• Wireless LAN
• RF Integrated Circuits
• Custom Applications
Dielectric
RF Performance
E/B
W
T
L
S Series BEST
C Series
BETTER
L Series GOOD
NPO
?
D
IELECTRIC
C
HARACTERISTICS
TEMPERATURE COEFFICIENT:
QUALITY FACTOR:
INSULATION RESISTANCE:
DIELECTRIC STRENGTH:
TEST PARAMETERS:
AVAILABLE CAPACITANCE:
0 ± 30ppm /°C, -55 to 125°C
2,500 min.,10,000 typical
R07/0402
Typical Series Resonant Frequency
10.0
Frequency (GHz)
>1,000 G @ 25°C,WVDC;
125°C IR is 10% of 25°C rating.
2.5 X WVDC Min., 25°C, 50 mA max
1MHz ±50kHz, 1.0±0.2 VRMS, 25°C
Size 0402:
Size 0603:
Size 0805:
Size 1210:
0.2 - 15 pF
0.2 - 47 pF
0.2 - 150 pF
0.5 - 1000 pF
R14/0603
R15/0805
1.0
0.8
1
10
Capacitance (pF)
100
200
H
OW TO
O
RDER
201
VOLTAGE
250 = 25 V
500 = 50 V
101 = 100 V
201 = 200 V
301 = 300 V
501 = 500 V
R15
CASE SIZE
See Chart
C
DIELECTRIC
C = High-Q NPO
101
CAPACITANCE
1st two digits are
significant; third digit
denotes number of
zeros, R = decimal.
1R0 = 1.0 pF
101 = 100 pF
J
TOLERANCE
** A = ± 0.05 pF
*
B = ± 0.10 pF
* C = ± 0.25 pF
F = ±1%
G = ± 2%
J = ± 5%
K = ± 10%
* Values < 10 pF
** Values < 2.0 pF
V
TERMINATION
V = Ni/Sn
4
E
TAPE MODIFIER
Code Type Reel
SIZES 0402 & 0603:
T
Paper 7”
Y
Paper
5”
SIZE 0805 & 1210:
E Embossed 7”
Z Embossed 5”
Tape specifications
conform to EIA RS481
MARKING
4 = Unmarked
6 = EIA “J” Code*
*For sizes 0805
Part number written: 201R15C101JV4E
10
www.johansontechnology.com
R15 / 0805 (2012)
R14 / 0603 (1608)
R07 / 0402 (1005)
A
VAILABLE
C
APACITANCE
S
ELECTION
S41 / 1210 (3224)
Inches
(mm)
Inches
(mm)
Inches
(mm)
Inches
(mm)
25 VDC
200 VDC
500 VDC
Length
.125 ±.010
(3.18 ±0.25)
Length
.080 ±.008
(2.03 ±0.20)
Length
.040 ±.004
(1.02 ±0.1)
Length
.062 ±.006
(1.57 ±0.15)
200 VDC
M
ECHANICAL
& E
NVIRONMENTAL
C
HARACTERISTICS
Width
.020 ±.004
(0.51 ±0.1)
Width
.050 ±.008
(1.27 ±0.20)
Width
.095 ±.010
(2.41 ±0.25)
This selection chart represents basic C/V capability in this series. Please contact the factory for capacitance, voltage, case size combinations not shown.
JTI C-Series Ceramic Capacitors conform to the environmental characteristics of the S-Series listed on page 7 of the JTI catalog.
www.johansontechnology.com
Width
Thickness
.032 ±.006 .030 +.005 -.003
(0.81 ±0.15)
(0.76 +.13-.08)
Thickness
.040 ±.006
(1.02 ±0.15)
Thickness
.060 Max
(1.52 Max)
End Band
.020 ±.010
(0.50 ±.25)
Thickness
.020 ±.004
(0.51 ±0.1)
100 VDC
End Band
.010 ±.006
(0.25 ±.15)
End Band
.014 ±.006
(0.35 ±.15)
End Band
.020 ±.010
(0.50 ±.25)
100
VDC
300 V
300 V
200 V
200 V
200 V
100 V
100 V
100 V
100 V
50 V
0.5
p
0.6 F
p
0.7 F
p
0.8 F
p
0.9 F
p
1.0 F
p
1.1 F
pF
1.2
p
1.3 F
p
1.5 F
p
1.8 F
pF
2.0
p
2.2 F
pF
2.4
p
2.7 F
p
3.0 F
p
3.3 F
pF
3.6
p
3.9 F
p
4.3 F
p
4.7 F
pF
5.1
p
5.6 F
pF
6.2
p
6.8 F
pF
7.5
p
8.2 F
pF
9.1
p
10 F
pF
12
p
15 F
p
18 F
p
20 F
p
22 F
p
27 F
p
33 F
p
39 F
p
47 F
p
56 F
p
68 F
p
82 F
p
10 F
0p
12 F
0
15 pF
0
18 pF
0
22 pF
0
27 pF
0
33 pF
0
39 pF
0
47 pF
0
56 pF
0
10 pF
00
pF
0.2
p
0.3 F
p
0.4 F
p
0.5 F
p
0.6 F
p
0.7 F
p
0.8 F
p
0.9 F
p
1.0 F
p
1.1 F
pF
1.2
p
1.3 F
p
1.5 F
p
1.8 F
pF
2.0
p
2.2 F
pF
2.4
p
2.7 F
p
3.0 F
p
3.3 F
pF
3.6
p
3.9 F
p
4.3 F
p
4.7 F
pF
5.1
p
5.6 F
pF
6.2
p
6.8 F
p
7.5 F
p
8.2 F
pF
9.1
p
10 F
pF
11
p
12 F
p
13 F
pF
15
p
16 F
pF
18
p
20 F
p
22 F
p
24 F
pF
27
p
30 F
p
33 F
p
36 F
pF
39
p
43 F
pF
47
p
56 F
p
68 F
p
82 F
p
10 F
0p
F
0.2
p
0.3 F
p
0.4 F
p
0.5 F
p
0.6 F
p
0.7 F
p
0.8 F
p
0.9 F
p
1.0 F
p
1.1 F
pF
1.2
p
1.3 F
p
1.5 F
p
1.8 F
pF
2.0
p
2.2 F
pF
2.4
p
2.7 F
pF
3.0
p
3.3 F
pF
3.6
p
3.9 F
p
4.3 F
p
4.7 F
pF
5.1
p
5.6 F
pF
6.2
p
6.8 F
pF
7.5
p
8.2 F
pF
9.1
p
10 F
pF
11
p
12 F
p
13 F
pF
15
p
16 F
pF
18
p
20 F
pF
22
p
24 F
pF
27
p
30 F
p
33 F
p
36 F
pF
39
p
43 F
pF
47
p
56 F
p
68 F
p
82 F
p
10 F
0p
F
0.5
p
0.6 F
p
0.7 F
p
0.8 F
p
0.9 F
p
1.0 F
p
1.1 F
p
1.2 F
p
1.3 F
p
1.5 F
p
1.8 F
pF
2.0
p
2.2 F
p
2.4 F
p
2.7 F
pF
3.0
p
3.3 F
p
3.6 F
p
3.9 F
pF
4.3
p
4.7 F
pF
5.1
p
5.6 F
p
6.2 F
p
6.8 F
pF
7.5
p
8.2 F
p
9.1 F
p
10 F
pF
11
p
12 F
p
13 F
pF
15
p
16 F
p
18 F
p
20 F
pF
22
p
24 F
p
27 F
p
30 F
pF
33
p
36 F
pF
39
p
43 F
p
47 F
p
56 F
p
68 F
p
82 F
p
10 F
0p
12 F
0p
15 F
0p
F
11
RF C
HARACTERISTICS VERSUS
F
REQUENCY
Equivalent Series Resistance: 0402/R07C
1
10000
B
J
B
H
F
B
J
B
H
F
J
B
Q
1000
H
F
B
J
H
F
100
B
J
H
F
B
B
J
J
H
F
H
F
B
J
H
F
Q Factor: 0402/R07C
ESR (Ohms)
0.1
H
F
B
B
J
H
B
F
J
B
H
B
F
J
B
B
H
F
J
B
B
J
0.01
0
500
'1.0 pF
'3.3 pF
H
F
'5.6 pF
'6.8 pF
B
'10 pF
'15 pF
10
B
J
1
'1.0 pF
'3.3 pF
H
F
'5.6 pF
'6.8 pF
'10 pF
'15 pF
1000
1500
Frequency (MHz)
2000
2500
0
500
1000
1500
Frequency (MHz)
2000
2500
Equivalent Series Resistance: 0603/R14C
1
10000
B
B
1000
J
H
F
100
J
H
F
Q
Q Factor: 0603/R14C
B
B
J
H
F
B
J
H
J
H
J
H
B
ESR (Ohms)
0.1
B
F
J
B
H
F
J
B
H
B
F
B
B
J
H
F
J
B
B
H
F
B
B
J
H
F
B
J
H
B
10
F
B
0.01
0
500
1000
1500
Frequency (MHz)
2000
2500
'1.0 pF
J
'4.7 pF
H
'10 pF
F
'22 pF
B
'47 pF
B
1
0
'1.0 pF
J
'4.7 pF
H
'10 pF
F
'22 pF
'47 pF
500
1000
1500
Frequency (MHz)
2000
2500
Equivalent Series Resistance: 0805/R15C
1
10000
B
J
1000
H
F
H
B
Q
100
F
B
10
B
0.01
0
500
1000
1500
Frequency (MHz)
2000
2500
'1.0 pF
Q Factor: 0805/R15C
B
J
B
J
B
J
H
H
F
H
H
B
J
J
ESR (Ohms)
0.1
F
H
B
B
J
J
F
B
B
H
H
J
F
B
B
H
J
B
B
F
B
H
F
J
B
F
H
J
J
'2.0 pF
H
'12 pF
F
'47 pF
B
130 pF
B
1
0
'1.0 pF
J
'2.0 pF
H
'12 pF
F
'47 pF
B
2000
130 pF
500
1000
1500
Frequency (MHz)
2500
Equivalent Series Resistance: 1210/S41C
1
B
B
B
10000
Q Factor: 1210/S41C
F
0.5 pF
'2.2 pF
J
P
'3.3 pF
'10 pF
B
1
56 pF
100 pF
B
B
1
J
H
F
B
B
1000
F
H
J
P
B
1
F
H
J
P
B
1
H
F
H
J
P
F
H
J
H
J
ESR (Ohms)
F
H
J
0.1
J
H
F
1
B
J
H
F
1
B
B
J
J
H
F
1
B
J
H
1
F
B
H
1
J
F
B
F
Q
100
P
0.5 pF
'2.2 pF
H
F
'3.3 pF
'10 pF
B
56 pF
1
100 pF
10
P
P
B
1
0
500
1000
1500
Frequency (MHz)
2000
2500
0.01
0
500
1000
1500
Frequency (MHz)
2000
2500
Measurements performed on a Boonton 34A Resonant Coaxial Line and represent typical capacitor performance.
12
www.johansontechnology.com
RF C
HARACTERISTICS VERSUS
C
APACITANCE
Equivalent Series Resistance: 0402/R07C
1
Q Factor: 0402/R07C
10000
B
B
ESR (Ohms)
0.1
H
B
J
H
J
B
H
J
B
H
J
B
H
J
B
B
H
J
B
1000
Q
100
B
B
B
B
0.01
1
150-250 MHz
J
900-1000 MHz
H
1900-2000 MHz
B
150-250 MHz
900-1000 MHz
1900-2000 MHz
10
10
Capacitance (pF)
20
1
Capacitance (pF)
10
20
Equivalent Series Resistance: 0603/R14C
1
Q Factor: 0603/R14C
10000
B
B
150-250 MHz
B
B
900-1000 MHz
1900-2000 MHz
1000
B
B
B
B
B
B
B
ESR (Ohms)
H
J
B
0.1
H
J
B
H
J
B
H
J
B
H
J
B
H H
J J
B B
H
J
B
H
J
B
H
J
Q
B
100
10
B
0.01
1
10
Capacitance (pF)
50
150-250 MHz
J
900-1000 MHz
H
1900-2000 MHz
1
1
10
Capacitance (pF)
50
Equivalent Series Resistance: 0805/R15C
1
Q Factor: 0805/R15C
10000
B
B
B
B
H
H
1000
B
B
ESR (Ohms)
H
J
0.1
B
H
J
B
H
J
B
H
J
B
H
J
H
J
H
J J
J
B
B BB
Q
100
B
B
B B
B
10
B
0.01
1
10
Capacitance (pF)
100
200
150-250 MHz
J
900-1000 MHz
H
1900-2000 MHz
B
150-250 MHz
900-1000 MHz
1900-2000 MHz
1
1
10
Capacitance (pF)
100
200
Equivalent Series Resistance: 1210/S41C
1
10000
B
Q Factor: 1210/S41C
B
B
B
B
B
1000
B
ESR (Ohms)
J
H
0.1
H
J
B
H
J
B
H H
J J
B
B
B
H
J
H
J
B
B
B
B
B
0.01
1
10
Capacitance (pF)
100
1000
150-250 MHz
H
J
J
J
Q
100
B
B
B
B
B
B
10
J
900-1000 MHz
H
1900-2000 MHz
B
150-250 MHz
900-1000 MHz
1900-2000 MHz
1
1
10
Capacitance (pF)
100
100
Measurements performed on a Boonton 34A Resonant Coaxial Line and represent typical capacitor performance.
As the title says, if it is possible, how can I do it? If not, please recommend me an operating system that can run in such a microcontroller. Thank you....
Input impedance refers to the equivalent impedance of a circuit input terminal. Add a voltage source U to the input terminal and measure the current I at the input terminal, then the input impedance R...
Do you often have to add brake fluid to your car's brakes? The fact that you need to pump out the brake fluid to make sure there is no gas in the brake fluid line may not be done by the car owner h...[Details]
For a long time, due to the limitation of hardware conditions, the display devices of traditional small handheld devices such as PDA are usually monochrome LCD, and the user interface is very simpl...[Details]
We know that microcontroller development tools generally include real-time online emulators and programmers. Among them, online emulators are very good tools, but they are also more expensive...[Details]
1. Overview
The Virtual CAN Interface (VCI) function library is an application program interface specifically provided for the use of ZLGCAN devices on PCs. The functions in the library ar...[Details]
1. Project Introduction
Shandong Dezhou Xingtai Paper Co., Ltd. is a newly built high-end paperboard production enterprise with domestic leading level established by Shandong Zhaodongfang Pape...[Details]
Capacitors
are basic components in various electronic devices and are widely used for bypassing, coupling,
filtering
, tuning, etc. in electronic circuits. However, to use capacitors,...[Details]
Abstract: In order to realize wireless automatic alarm and monitoring of major safety places, based on the basic principle of pyroelectric infrared sensing, a detector for receiving infrared radia...[Details]
1 Load Regulation
Changes in power supply load will cause changes in power supply output. When the load increases, the output decreases, and vice versa, when the load decreases, the output inc...[Details]
The power consumption of a switching power supply includes fixed losses caused by parasitic resistances such as semiconductor switches, magnetic components, and wiring, as well as switching losses ...[Details]
In recent years, the application of single-chip microcomputer systems in the field of industrial measurement and control has become more and more extensive. However, for industrial sites with harsh...[Details]
0 Introduction
The tobacco leaf curing process is a key step in producing high-quality tobacco leaves, and the quality of flue-cured tobacco is closely related to the temperature and humidit...[Details]
Background
The proliferation of ultra-low-power wireless sensor nodes for measurement and control purposes, combined with new energy harvesting techniques, has made it possible to create ful...[Details]
Multimedia applications such as mobile TV, mobile gaming, and audio playback present a huge challenge to power management design in mobile phones. Mobile phone designers need to keep the phone smal...[Details]
In the industrial production process, flow measurement is a widely used measurement physical quantity. In special cases, such as vertical oil wells, when it is not easy to install probes outside the p...[Details]
With the development of my country's economy, environmental pollution caused by energy consumption is becoming more and more serious. Sulfur dioxide and nitrogen oxides emitted from coal-fired flue...[Details]