F1100/F1150F/F1199 RFI Filters
Features:
• Most Economical Design
• Designed for General Purpose, Common Mode
Applications
• Available in Standard (F1100) and Low-Leakage (F1150)
(F1160) (F1170) (F1180) (F1190) (F1199) Models
General Purpose
F1100/F1150/F1199
Simplified Schematic
L
LINE
G
N
Nominal
Current
Rating
115 VAC
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
Part
Number
F1100AA01
F1100BB01
Termination
Line/Load
QC/QC
Wire/Wire
QC/QC
Wire/Wire
QC/QC
QC/QC
Wire/Wire
QC/QC
Wire/Wire
PC/PC
QC/QC
Wire/Wire
QC/QC
Wire/Wire
QC/QC
Wire/Wire
QC/QC
Wire/Wire
QC/QC
Wire/Wire
QC/QC
Wire/Wire
QC/QC
Wire/Wire
QC/QC
Wire/Wire
Screw/Screw
QC/QC
Screw/Screw
QC/QC
Screw/Screw
QC/QC
Screw/Screw
Screw/Screw
MODE
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Common
Differential
Frequency - MHz
.15
20
20
32
5
24
5
20
20
20
5
10
10
9
5
10
10
9
5
8
8
10
5
13
5
.50
35
30
45
14
35
13
35
30
30
12
22
2
20
2
20
12
22
20
20
12
18
15
20
12
23
12
1.0
43
37
45
23
43
16
43
37
38
14
30
5
27
5
28
14
30
2
27
2
25
14
22
5
20
5
28
15
30
15
5.0
52
55
50
55
43
47
45
45
52
55
50
55
48
38
46
51
45
51
42
33
46
27
45
27
38
33
36
22
32
22
35
30
35
30
10
55
65
50
65
43
50
45
50
55
64
50
64
48
44
50
57
45
57
50
42
50
47
45
47
42
42
42
46
38
46
38
40
38
40
30
50
50
50
50
40
45
40
45
50
46
50
46
44
42
45
49
45
49
47
42
45
50
45
50
40
42
45
60
45
60
40
40
40
40
SINGLE PHASE FILTERS
1A
2A
3A
F1150AA01
F1150BB01
F1199AA01
F1199AA02
F1199BB02
F1100AA03
F1100BB03
F1100PP03
F1150AA03
F1150BB03
F1199AA03
F1199BB03
F1100AA06
F1100BB06
6A
F1150AA06
F1150BB06
F1199AA06
F1199BB06
F1100AA10
F1100BB10
10A
F1150AA10
F1150BB10
F1199AA10
F1199BB10
F1199DD10
F1100AA20
F1100DD20
20A
30A
4
F1150AA20
F1150DD20
F1199AA20
F1199DD20
F1199DD30
NOTE: Other combinations of terminals may be specified on special order.
www.curtisind.com
Curtis Industries
A Division of Powers Holdings, Inc.
Specifications subject to change.
Dimensions are shown for
reference purposes only.
Specifications
:
Rated Voltage:
250VAC Maximum - 50/60 Hz
Rated Current:
115VAC
250VAC
1A
1A
2A
1.5A
3A
2.5A
6A
4A
10A
6A
20A
10A
30A
15A
Current Overload:
6X for 8 seconds
Hi-Pot Test (1 min):
F1100/F1150
F1199
Line to Ground:
1500VAC
1500VAC
Line to Line:
1768VDC
1450VDC
9
Insulation Resistance:
9 x 10
Ω
at 100VDC
Ambient Temperature:
40°C Max. at rated current
Humidity Range:
0% to 95% R.H.
Termination:
A: QC – Quick Connect
D: Screw
B: Wire
P: PCB Mount
Maximum Leakage Current:
Each Line to Ground
F1100
F1150
F1199
115VAC, 60Hz:
0.40mA
0.25mA
0.25mA
250VAC, 50Hz:
.75mA
0.40mA
0.45mA
Agency Approvals:
F1100AA/F1150AA
(1, 3, 6, 10 and 20Amp) Dimensions
Amps
A
2.500
(63,5)
2.500
(63,5)
2.500
(63,5)
2.500
(63,5)
2.760
(70,6)
.188 Dia.
B
1.750
(44,5)
1.750
(44,5)
1.750
(44,5)
1.750
(44,5)
2.000
(60,8)
C
.625
(15,8)
.750
(19,1)
.750
(19,1)
1.125
(28,5)
1.125
(28,5)
D
2.125
(53,9)
2.125
(53,9)
2.125
(53,9)
2.125
(53,9)
2.375
(60,3)
E
1.425
(362)
1.8
(45,8)
1A
3A
6A
10A
20A
General Purpose
1.8
(45,8)
1.8
(45,8)
2.550
(64,8)
(4,77) 2 Holes
L
I
N
E
L
O
A
D
A
B
D
SINGLE PHASE FILTERS
E
C
.250 Q.C.
(6.4)
F1150
F1199
F1100
F1500
F1199
F1100
Except 20Amp
F1199
F1100
F1150
F1199
F1100BB/FB1150BB
(1, 3, 6 and 10Amp) Dimensions
Amps
A
2.500
(63,5)
2.500
(63,5)
2.500
(63,5)
2.500
(63,5)
B
1.750
(44,5)
1.750
(44,5)
1.750
(44,5)
1.750
(44,5)
C
.625
(15,8)
.750
(19,1)
.750
(19,1)
1.125
(28,5)
D
2.125
(53,9)
2.125
(53,9)
2.125
(53,9)
2.125
(53,9)
E
.875
(22,2)
1.250
(31,8)
1.250
(31,8)
1.250
(31,8)
F1100DD/F1150DD
(20Amp Only) Dimensions
.188 Dia.
(4,77) 2 Holes
1A
3A
6A
10A
2.000
(50,8)
L
I
N
E
L
O
A
D
2.760
(70,6)
2.375
(60,3)
.188 Dia.
(4,77) 2 Holes
(5) No. 8-32
.625
Studs
B
2.000
(50,8)
.625
(15,8)
1.125
(25,5)
(15,8)
L
I
N
E
L
O
A
D
A
D
E
4.000
(101,6)
Min.
.250±.062
(6,35) Typ.
C
No. 18 Gauge Wire
Dimensions are in inches and millimeters
unless otherwise specified.
Values in parentheses are metric equivalents.
Curtis Industries
A Division of Powers Holdings, Inc.
1-800-657-0853
5
F1100/F1150/F1199 RFI Filters
(continued)
F1199AA
(1, 2, 3, 6, 10 and 20Amp) Dimensions
Amps
A
2.53
(64,3)
2.53
(64,3)
2.53
(64,3)
2.53
(64,3)
2.53
(64,3)
2.81
(71,4)
B
1.82
(46,2)
1.82
(46,2)
1.82
(46,2)
1.82
(46,2)
1.82
(46,2)
2.07
(52,6)
C
0.66
(16,8)
0.66
(16,8)
0.78
(19,8)
0.78
(19,8)
1.16
(29,5)
1.16
(29,5)
D
2.126
(54,0)
2.126
(54,0)
2.126
(54,0)
2.126
(54,0)
2.126
(54,0)
2.375
(60,33)
E
2.25
(57,2)
2.25
(57,2)
2.61
(66,3)
2.61
(66,3)
2.61
(66,3)
3.36
(85,3)
F1199BB
(2, 3, 6 and 10Amp) Dimensions
Amps
A
2.53
(64,3)
2.53
(64,3)
2.53
(64,3)
2.53
(64,3)
B
1.82
(46,2)
1.82
(46,2)
1.82
(46,2)
1.82
(46,2)
C
0.66
(16,8)
0.78
(19,8)
0.78
(19,8)
1.16
(29,5)
D
2.126
(54,0)
2.126
(54,0)
2.126
(54,0)
2.126
(54,0)
E
0.96
(24,4)
1.32
(33,5)
1.32
(33,5)
1.32
(33,5)
1A
2A
2A
3A
6A
10A
General Purpose
3A
6A
10A
20A
WIRE LEADS, 18AWG,
(16AWG FOR 10A).
102(4.0) MIN.
BLUE
BLUE
G/Y
BROWN
BROWN
6.36(0.25) FASTON TERMINAL
WITH Ø1.78 (0.070) HOLE
(SLOTTED HOLE
FOR GROUND)
A D
B
SINGLE PHASE FILTERS
A D
B
E
C
E
C
F1199DD
(10, 20 and 30Amp) Dimensions
Amps
A
2.53
(64,3)
2.81
(71,4)
4.20
(106,7)
B
1.82
(46,2)
2.07
(52,6)
3.38
(85,9)
C
1.16
(29,5)
1.16
(29,5)
1.53
(38,9)
D
2.126
(54,0)
2.375
(60,33)
3.75
(95,25)
E
2.72
(69,1)
3.46
(87,9)
5.34
(135,6)
1.75
MOUNTING
FLANGE
#8-3 SCREW
TERMINAL
10A
20A
30A
F1100PP
Recommended PC Mounting
.250 Dia. Pads
5 Places
.210
1.25
Stamp this surface
.062 Dia. Hole
5 Places
A D
B
L
I
N
E
L
O
A
D
.500
.750
E
C
1.00
.75
6
www.curtisind.com
Curtis Industries
A Division of Powers Holdings, Inc.
Specifications subject to change.
Dimensions are shown for