EEWORLDEEWORLDEEWORLD

Part Number

Search

B2M-221138

Description
RF Relay, 1 Form C, SPDT, Latched, 18VDC (Coil), 2MHz, DC Input, Random, Panel Mount,
CategoryMechanical and electronic products    relay   
File Size261KB,2 Pages
ManufacturerCharter Engineering Inc
Download Datasheet Parametric View All

B2M-221138 Overview

RF Relay, 1 Form C, SPDT, Latched, 18VDC (Coil), 2MHz, DC Input, Random, Panel Mount,

B2M-221138 Parametric

Parameter NameAttribute value
MakerCharter Engineering Inc
Reach Compliance Codeunknown
body width13.208 mm
body height37.25 mm
Body length or diameter45.72 mm
Characteristic impedance50 Ω
Maximum coil voltage (DC)18 V
Nominal coil voltage15 V
Coil/Input Power TypeDC
Electrical life1000000 Cycle(s)
End contact materialCopper Alloy
End contact platingGOLD
Input switching control typeRandom
Maximum insertion loss0.2 dB
Maximum isolation90 dB
Installation featuresPANEL MOUNT
Number of terminals6
Maximum operating frequency2 MHz
Minimum operating frequency
Maximum operating temperature90 °C
Minimum operating temperature-40 °C
physical size45.72mm X 13.2mm X 37.25mm
Relay actionLATCHED
Relay style1 FORM C
Relay functionSPDT
Relay typeRF RELAY
surface mountNO
switching time20 ms
Terminal length0.005 inch
Termination typeSOLDER
voltage standing wave ratio1.2
FREQUENCY:
GHz
DC - 2.0
1.20:1
2.0 - 4.0
1.25:1
4.0 - 8.0
1.30:1
8.0 - 12.4
1.40:1
12.4 - 18.0
1.50:1
18.0 - 26.5
1.65:1
B2 SERIES
SP2T
DC - 26.5 GHz
VSWR (MAX.)
INSERTION
LOSS (MAX.)
ISOLATION
(MIN.)
IMPEDANCE
0.20
0.25
0.30
0.40
0.50
0.70
90
80
80
50 Ohms
70
60
50
MECHANICAL
CONTACT
ACTUATOR
SWITCHING SPEED
ELECTRICAL
ACTUATOR VOLTAGE
ACTUATOR CURRENT
POWER HANDLING
ENVIRONMENTAL
OPERATING TEMP
SHOCK
RANDOM VIBRATION
LIFE
FINISH
RF CAVITY
ENCLOSURE
CONTACT
CONNECTOR SHELL
NOTE
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
BREAK BEFORE MAKE
FAILSAFE, LATCHING, MOMENTARY
20 mSEC MAX.
28.0, 12.0, 15.0, 24.0 Vdc
CONTACT CEI
200 WCW @ 1.0 GHz (STANDARD)
300 WCW @ 1.0 GHz (OPT. /P)
-40 DEG. C TO 90 DEG. C (STANDARD)
-54 DEG. C TO 90 DEG. C (OPT. /MS)
(OPT /MS NOT AVAILABLE WITH TTL LOGIC)
50 G’S rms (SAWTOOTH)
15 G’S rms (NON-OPERATING)
1,000,000 CYCLES
ALUMINUM ELECTROLESS NICKEL PLATED
PER MIL-C-26074, CLASS 4
(EXCEPT LOW OR ULTRA LOW IM MODELS)
ALUMINUM, BLUE OR BLACK
BERYLLIUM COPPER, GOLD PLATED
PER MIL-G-45204
CRES, PASSIVATED PER QQ-P-35 OR BRASS,
ELECTROLESS NICKEL PLATED
PER MIL-C-26074
FINISH MAY VARY FOR /MS VERSION
AVAILABLE OPTIONS
INDICATOR CIRCUITRY :
CUT OFF POWER CIRCUIT
SUPPRESSION DIODE :
CUSTOM DESIGNS
TTL LOGIC
:
LOW, ULTRA LOW, AND SUPERIOR INTERMODULATION (IM)
PAGE 16
CHARTER ENGINEERING, INC.
INTERNET: http://www.ceiswitches.com
EMAIL:sales@ceiswitches.com
Beijing listed communication group company recruits: DSP (2 algorithm drivers)
DSP algorithm engineer job responsibilities: Responsible for the development and maintenance of the physical layer software of terminal products. Responsible for the verification, implementation and o...
andehr03 Talking about work
A question about sensor knowledge, urgent!!!
[i=s]This post was last edited by paulhyde on 2014-9-15 09:44[/i] How to implement an infrared temperature sensor to distinguish between people coming in and going out? Experts with ideas, please give...
roc19850 Electronics Design Contest
Ask a question about CH340T
Ask a question: Does CH340T support WIN10?...
wufeijian Integrated technical exchanges
Verilog simulation is different from the book
[code] module shunxu(q0,q1,q2,clk,clr); output q0,q1,q2; input clk,clr; reg q0,q1,q2; reg[2:0] x,y; always @(posedge clk) begin if(clr) begin y='b000;x='b001;end else begin y=x; x={x[1:0],x[2]}; end q...
常见泽1 FPGA/CPLD
Questions about using Verilog HDL language programming in IspLever Classic
The problem is this: I want to use Verilog HDL language in IspLever Classic to program the GAL16V8D chip, but the following error appears when creating the file: Schematic/Verilog HDL design entry is ...
eeleader-mcu FPGA/CPLD
stm32F107 +83848 100M can receive data but cannot send data
107+83848 can send and receive in forced 10M mode, can receive data but cannot send data in forced 100M mode, and is the same in adaptive mode as in 100M mode. How to solve this problem?...
L_686 stm32/stm8

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1093  328  2580  2450  269  23  7  52  50  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号