EEWORLDEEWORLDEEWORLD

Part Number

Search

D378-W9LD

Description
Snap Acting/Limit Switch, SPST, On-(off), Momentary, 5.6mm, Screw Terminal, Straight Type Actuator, Panel Mount,
CategoryMechanical and electronic products    switch   
File Size2MB,3 Pages
ManufacturerThe Cherry Corporation
Environmental Compliance
Download Datasheet Parametric View All

D378-W9LD Overview

Snap Acting/Limit Switch, SPST, On-(off), Momentary, 5.6mm, Screw Terminal, Straight Type Actuator, Panel Mount,

D378-W9LD Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerThe Cherry Corporation
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator angle
Executor completedNICKEL
Actuator length1.4 inch
Actuator materialSTEEL
Actuator stroke5.6 mm
Actuator typeSTRAIGHT TYPE
Other featuresLIGHT FORCE, STANDARD RATIO
body width10.3 mm
body height15.9 mm
Body length or diameter27.8 mm
center contact materialBERYLLIUM COPPER
Center contact platingSILVER
Contact (AC) maximum rated load M2A@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Contact functionON-(OFF)
contact timeSNAP ACTION
Maximum contact voltage (AC)250 V
Electrical life6000 Cycle(s)
End contact materialBERYLLIUM COPPER
End contact platingSILVER
Shell materialPOLYESTER
insulator materialPOLYESTER
Manufacturer's serial numberD3
Installation featuresPANEL MOUNT
Maximum operating force65 N
work location0.685 inch
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum pre-travel3.5 mm
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSCREW
MINIATURE
D3 Series
Features
q
Self-cleaning effect of wiping contact
mechanism provides excellent reliability
Suitable for low actuation speeds
Highly flexible, due to
two mounting positions and a
variety of auxiliary actuators
Wide variety of terminal types
> 3mm (0.12″) contact gap available
POM actuating button
q
q
PET cover and base
q
q
NO terminal
Stainless steel spring
NC terminal
Silver contacts
Common terminal
Electrical Ratings
Switch
Series
EN61058 Rating
UL1054 Rating
Electrical Life at Rated Load
According to EN
According to UL
(Min. Operations)
(Min. Operations)
D36 – Std.
D37 – Std.
D38 – Std.
D36 – Light
D37 – Light
D38 – Light
4(2.5)A, 250V~
10(3)A, 250V~
16(4)A, 250V~
10(3)A, 400V~
4(1)A, 250V~
10(2)A, 250V~
16(2.5)A, 250V~
10(1.5)A, 400V~
4A, 250VAC
10A, 1/2HP, 125/250VAC
16A, 125/250VAC, 1HP
4A, 250VAC
10A, 1/2HP, 125/250VAC
16A, 125/250VAC, 1HP
50,000
50,000
50,000
50,000
50,000
50,000
6,000
6,000
6,000
6,000
6,000
6,000
Specifications
Electrical
Temperature Rating:
Flammability Rating:
Materials
-40° to +85°C
UL94V-O
PET
POM
Stainless Steel; Nickel-Plated Steel
Copper-Zinc
Silver Cadmium Oxide
Case:
Actuator:
Auxiliary Actuator:
Terminals:
Contacts:
PET = Polyethyleneterephthalate • POM = Polyacetal
36
Will the level of the national electronic design competition be lowered?
[i=s]This post was last edited by paulhyde on 2014-9-15 03:42[/i] [size=4][b]After receiving the first prize certificate, I found that there was no seal from the Ministry of Education or the Ministry ...
ckx提问 Electronics Design Contest
[Video] Accelerate design development time using hard-core floating-point DSP blocks in FPGA
[media=swf,500,375]http://player.youku.com/player.php/sid/XNzI4NTI3MzMy/v.swf[/media]...
chenzhufly FPGA/CPLD
There is a problem with the following ucos task, please help me take a look!
#include includes.h #if 1 unsigned int time_temp1; unsigned int time_temp2;#endif#if 1 int flag_temp_past[CAN_FIFO_SIZE]={0}; int temp_high[CAN_FIFO_SIZE]={0}; int past_high[CAN_FIFO_SIZE]={0};#endife...
danner Real-time operating system RTOS
How to make a smart fish tank? [Creative sharing]
I read this article yesterday and thought it was great, so I'd like to share it with you~ It can realize fully automatic supply, such as: 1. Automatic sensing of water temperature 2. Automatic constan...
sdfsdfsbv Programming Basics
Regarding the discussion on the output frequency accuracy in SVPWM control, experts are welcome! (with program)
[i=s] This post was last edited by dontium on 2015-1-23 11:41 [/i] Dear experts, the following program has only 0.15hz resolution when changing frequency (carrier is 10Khz), that is, for every increas...
69056001 Analogue and Mixed Signal
Flow meter sensor current is too high
1. The flow meter is burned out due to the instability (too high) of the DC24V power switch on site, which causes the current to be too high. How to connect the resistor in series and how big the resi...
tw随缘 Sensor

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2613  1626  815  2115  929  53  33  17  43  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号