EEWORLDEEWORLDEEWORLD

Part Number

Search

D3V-65-3A4-K

Description
Snap Acting/Limit Switch, SPST, Momentary, 6A, 8VDC, 2.4mm, Quick Connect Terminal, Short Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size1MB,14 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance  
Download Datasheet Parametric View All

D3V-65-3A4-K Overview

Snap Acting/Limit Switch, SPST, Momentary, 6A, 8VDC, 2.4mm, Quick Connect Terminal, Short Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

D3V-65-3A4-K Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke2.4 mm
Actuator typeSHORT HINGE ROLLER LEVER
body width10.3 mm
body height15.9 mm
Body length or diameter27.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact current (DC)6 A
Contact (DC) maximum rated R load6A@8VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)8 V
Electrical life500000 Cycle(s)
Manufacturer's serial numberD3V
Installation featuresPANEL MOUNT
Maximum operating force1.18 N
Maximum operating temperature105 °C
Minimum operating temperature-25 °C
Maximum pre-travel1.6 mm
sealIP00
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
Miniature Basic Switch
D3V
Reliable Basic Switch with External Lever
• Available by 0.1 A, 6 A, 11 A, 16 A and 21 A models, all with
self-cleaning contacts. 0.1 A utilizes gold alloy crossbar
contacts for high reliability at low loads.
• Available with internally or externally fitted levers, and 2 fix-
ing positions for external levers.
• Conforms to EN61058-1 UL1054.
• Right-angle plunger option available in some models.
• RoHS Compliant.
Ordering Information
Model Number Legend
D3V-@@@@-@@@-@-@
1 2 3 4
5 6 7
8
9
6. Terminals
A:
Solder/quick-connect terminal (#187)
C2: Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
(optional without surge creepage tab flush around
terminals.)
7. Maximum Operating Force
5:
1.96 N {200 gf}
4A: 1.23 N {125 gf}
4:
0.98 N {100 gf}
3:
0.49 N {50 gf}
2:
0.25 N {25 gf}
Note:
These values are for the plunger models.
8. Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
9. Special Code
None: Standard
H:
High temperature (125° C)
E:
Special rating: 21 (8) A
T:
High temperature (200
°
C)
1. Ratings
21: 20 (4) A at 250 VAC
16: 16 (3) A at 250 VAC
11: 11 (3) A at 250 VAC
6:
6 (2) A at 250 VAC
01: 0.1 A at 125 VAC
2. Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
3. Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
4. Hinge Position
None: Internal/Far from plunger
M:
External/Far from plunger
K:
External/Near plunger
5. Contact Form
1:
SPDT
2:
SPST-NC
3:
SPST-NO
Miniature Basic Switch
D3V
1
Multiple source program modules have been declared, why does main prompt that the module program function is not declared?
#include #include#include "twi.h" #include "uart.h" #define SET_1(a,b) a|=(1 #include #include/******************************* I2C status definition: MT master sends, MR master receives **************...
lhp8203 Microchip MCU
【Book Collection】Mathematical Handbook for Electricians and Telecommunications Engineers (Volumes 1 and 2)
[b]Contents: [/b] Chapter 1 Complex Functions Chapter 2 Fourier Series and Fourier Integral Chapter 3 Vector Operations Chapter 4 Matrix Computations Chapter 5 Basic Concepts of Tensors and Their Appl...
wzt Analog electronics
How to use FFT to find the signal frequency when the input value is an unsigned number
I am working on a problem and have run into difficulties. I am at a loss for ideas and would like to seek advice from experts. The input data is a DTMF signal (the superposition of two sine waveforms)...
sunnyou Embedded System
In-depth review: STM32 Nucleo BlueNRG Part 3 [Use mobile phone Bluetooth to switch song MP3 playback]
I happened to have a few MP3 player modules on hand, so I used Nucleo to control the music playback, and used my phone as a remote control to switch the songs played. This is just for entertainment, h...
arthasarthas stm32/stm8
2k nand driver problem
2440+k9f1g08 platform follows the development board, and changes the driver of 512b/page to 2k/page. A problem occurs and I don't know how to solve it. After burning NK, the system can start once, but...
wzhang04 Embedded System
Single Supply Operation of Operational Amplifiers
Single-supply technology for operational amplifiers....
92475 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2744  409  1647  2479  1869  56  9  34  50  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号