EEWORLDEEWORLDEEWORLD

Part Number

Search

D3V-65-3C4

Description
Snap Acting/Limit Switch, SPST, Momentary, 6A, 8VDC, 2.4mm, Quick Connect Terminal, Short Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size1MB,14 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance  
Download Datasheet Parametric View All

D3V-65-3C4 Overview

Snap Acting/Limit Switch, SPST, Momentary, 6A, 8VDC, 2.4mm, Quick Connect Terminal, Short Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

D3V-65-3C4 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke2.4 mm
Actuator typeSHORT HINGE ROLLER LEVER
body width10.3 mm
body height15.9 mm
Body length or diameter27.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact current (DC)6 A
Contact (DC) maximum rated R load6A@8VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)8 V
Electrical life500000 Cycle(s)
Manufacturer's serial numberD3V
Installation featuresPANEL MOUNT
Maximum operating force1.18 N
Maximum operating temperature105 °C
Minimum operating temperature-25 °C
Maximum pre-travel1.6 mm
sealIP00
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
Miniature Basic Switch
D3V
Reliable Basic Switch with External Lever
• Available by 0.1 A, 6 A, 11 A, 16 A and 21 A models, all with
self-cleaning contacts. 0.1 A utilizes gold alloy crossbar
contacts for high reliability at low loads.
• Available with internally or externally fitted levers, and 2 fix-
ing positions for external levers.
• Conforms to EN61058-1 UL1054.
• Right-angle plunger option available in some models.
• RoHS Compliant.
Ordering Information
Model Number Legend
D3V-@@@@-@@@-@-@
1 2 3 4
5 6 7
8
9
6. Terminals
A:
Solder/quick-connect terminal (#187)
C2: Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
(optional without surge creepage tab flush around
terminals.)
7. Maximum Operating Force
5:
1.96 N {200 gf}
4A: 1.23 N {125 gf}
4:
0.98 N {100 gf}
3:
0.49 N {50 gf}
2:
0.25 N {25 gf}
Note:
These values are for the plunger models.
8. Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
9. Special Code
None: Standard
H:
High temperature (125° C)
E:
Special rating: 21 (8) A
T:
High temperature (200
°
C)
1. Ratings
21: 20 (4) A at 250 VAC
16: 16 (3) A at 250 VAC
11: 11 (3) A at 250 VAC
6:
6 (2) A at 250 VAC
01: 0.1 A at 125 VAC
2. Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
3. Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
4. Hinge Position
None: Internal/Far from plunger
M:
External/Far from plunger
K:
External/Near plunger
5. Contact Form
1:
SPDT
2:
SPST-NC
3:
SPST-NO
Miniature Basic Switch
D3V
1
I need help from the experts. I am a novice. I don't know how to use the FPGA development board of Jingwei Yager.
A novice doesn't know how to use the FPGA development board of Jingwei Yager. For example, what are the interfaces for? How to allocate the pins? Do I need to understand the schematic diagram?...
以沫西西 FPGA/CPLD
Hello everyone
hey: Hello everyone, I'm kingna, very happy to meet more friends here. We have some job opportunities here, I don't know if any friends will be interested, because I don't know what field you are enga...
似曾相识 Embedded System
[Award Ceremony] List of winners of TI Community’s Annual Star Netizen in 2012!
[font=微软雅黑] [/font] [font=微软雅黑]Looking back at 2012, many EEWORLD netizens gathered in the TI community. Because of everyone's presence, the atmosphere of the TI technical community has become active....
EEWORLD社区 TI Technology Forum
altium designer 09Why do the components on the schematic show no driver after the switch is turned on?
I use altium designer 09. After designing the schematic, it reports an error message "has no driver" when I run it. It starts with the main switch. I don't know where the error is....This is the error...
lzlnll PCB Design
When debugging, why can't it stop at the entry function main() after B __main? Please help, otherwise I will stay up all night!!!
The purpose is to call the C standard function library, so add #include in the file where main() is located #includelibExecute B __main in assembly. The result is that it does not go to main() as expe...
ahjxxy Embedded System
Why can't GPIOPinRead read the pin value?
Why can't GPIOPinRead read the pin value?...
古跃 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2920  330  477  169  1776  59  7  10  4  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号