• Underwriters Laboratory Recognition under UL standard
for safety 497B: Isolated Loop Circuit Protection
• Glass passivated junction
• 600W peak pulse power capabililty with a 10/1000µs
waveform, repetition rate (duty cycle): 0.01%
• Excellent clamping capability
• Low incremental surge resistance
• Very fast response time
0.300 (7.6)
0.230 (5.8)
0.140 (3.6)
0.104 (2.6)
Dia.
1.0 (25.4)
min.
Case:
JEDEC DO-204AC molded plastic body over
passivated junction
Terminals:
Solder plated axial leads, solderable per MIL-
STD-750, Method 2026
High temp. soldering guaranteed:
265°C/10 seconds,
0.375” (9.5mm) lead length, 5lbs. (2.3 kg) tension
Polarity:
For unidirectional types the color band denotes
the cathode, which is positive with respect to the anode
under normal TVS operation
Mounting Position:
Any
Weight:
0.015 oz., 0.4 g
Flammability:
Epoxy is rated UL 94V-0
Packaging Codes – Options (Antistatic):
51 – 1K per Bulk box, 10K/carton
54 – 4K per 13" paper Reel
(52mm horiz. tape), 12K/carton
73 – 2K per horiz. tape & Ammo box, 20K/carton
Devices for Bidirectional Applications
For bi-directional devices, use suffix C or CA for types P6KE6.8 through types P6KE440 (e.g. P6KE6.8C, P6KE440CA).
Electrical characteristics apply in both directions.
Maximum Ratings and Characteristics
Parameter
T
A
=25
O
C unless otherwise noted.
Symbol
P
PPM
I
PPM
P
M(AV)
I
FSM
V
F
R
θJL
R
θJA
T
J
, T
STG
Value
600
See Next Table
5.0
100
3.5/5.0
20
75
–55 to +175
Unit
W
A
W
A
V
°C/W
°C/W
O
Peak power dissipation with a 10/1000µs waveform
(1)
(Fig. 1)
Peak pulse current wih a 10/1000µs waveform
(1)
Steady state power dissipation
at T
L
=75
O
C, lead lengths 0.375” (9.5mm)
(2)
Peak forward surge current, 8.3ms single half sine-wave
(3)
Maximum instantaneous forward voltage
at 50A for unidirectional only
(4)
Typical thermal resistance junction-to-lead
Typical thermal resistance junction-to-ambient
Operating junction and storage temperature range
C
Notes:
(1) Non-repetitive current pulse, per Fig.3 and derated above T
A
= 25°C per Fig. 2
(2) Mounted on copper pad area of 1.6 x 1.6” (40 x 40mm) per Fig. 5
(3) Measured on 8.3ms single half sine-wave or equivalent square wave, duty cycle = 4 per minute maximum
(4) V
F
= 3.5V for P6KE220(A) & below; V
F
= 5.0V for P6KE250(A) & above
Document Number 88369
09-Oct-02
www.vishay.com
1
P6KE Series
Vishay Semiconductors
formerly General Semiconductor
Electrical Characteristics
Ratings at 25°C ambient temperature unless otherwise specified.
Breakdown Voltage
V
(BR)
at I
T
(1)
(V)
Device Type
+P6KE6.8
+P6KE6.8A
+P6KE7.5
+P6KE7.5A
+P6KE8.2
+P6KE8.2A
+P6KE9.1
+P6KE9.1A
+P6KE10
+P6KE10A
+P6KE11
+P6KE11A
+P6KE12
+P6KE12A
+P6KE13
+P6KE13A
+P6KE15
+P6KE15A
+P6KE16
+P6KE16A
+P6KE18
+P6KE18A
+P6KE20
+P6KE20A
+P6KE22
+P6KE22A
+P6KE24
+P6KE24A
+P6KE27
+P6KE27A
+P6KE30
+P6KE30A
+P6KE33
+P6KE33A
+P6KE36
+P6KE36A
+P6KE39
+P6KE39A
+P6KE43
+P6KE43A
+P6KE47
+P6KE47A
+P6KE51
+P6KE51A
+P6KE56
+P6KE56A
+P6KE62
+P6KE62A
+P6KE68
+P6KE68A
+P6KE75
+P6KE75A
+P6KE82
Min
6.12
6.45
6.75
7.13
7.38
7.79
8.19
8.65
9.00
9.50
9.90
10.5
10.8
11.4
11.7
12.4
13.5
14.3
14.4
15.2
16.2
17.1
18.0
19.0
19.8
20.9
21.6
22.8
24.3
25.7
27.0
28.5
29.7
31.4
32.4
34.2
35.1
37.1
38.7
40.9
42.3
44.7
45.9
48.5
50.4
53.2
55.8
58.9
61.2
64.6
67.5
71.3
73.8
Max
7.48
7.14
8.25
7.88
9.02
8.61
10.0
9.55
11.0
10.5
12.1
11.6
13.2
12.6
14.3
13.7
16.5
15.8
17.6
16.8
19.8
18.9
22.0
21.0
24.2
23.1
26.4
25.2
29.7
28.4
33.0
31.5
36.3
34.7
39.6
37.8
42.9
41.0
47.3
45.2
51.7
49.4
56.1
53.6
61.6
58.8
68.2
65.1
74.8
71.4
82.5
78.8
90.2
Test
Current
I
T
(mA)
10
10
10
10
10
10
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Stand-off
Voltage
V
WM
(V)
5.50
5.80
6.05
6.40
6.63
7.02
7.37
7.78
8.10
8.55
8.92
9.40
9.72
10.2
10.5
11.1
12.1
12.8
12.9
13.6
14.5
15.3
16.2
17.1
17.8
18.8
19.4
20.5
21.8
23.1
24.3
25.6
26.8
28.2
29.1
30.8
31.6
33.3
34.8
36.8
38.1
40.2
41.3
43.6
45.4
47.8
50.2
53.0
55.1
58.1
60.7
64.1
66.4
Maximum
Reverse
Leakage
at V
WM
(3)
I
D
(µA)
1000
1000
500
500
200
200
50
50
10
10
5.0
5.0
5.0
5.0
5.0
5.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Peak Pulse
Current
I
PPM
(2)
(A)
55.6
57.1
51.3
53.1
48.0
49.6
43.5
44.8
40.0
41.4
37.0
38.5
34.7
35.9
31.6
33.0
27.3
28.3
25.5
26.7
22.6
23.8
20.6
21.7
18.8
19.6
17.3
18.1
15.3
16.0
13.8
14.5
12.6
13.1
11.5
12.0
10.6
11.1
9.7
10.1
8.8
9.3
8.2
8.6
7.5
7.8
6.7
7.1
6.1
6.5
5.6
5.8
5.1
Maximum
Clamping
Voltage at
I
PPM
V
C
(V)
10.8
10.5
11.7
11.3
12.5
12.1
13.8
13.4
15.0
14.5
16.2
15.6
17.3
16.7
19.0
18.2
22.0
21.2
23.5
22.5
26.5
25.2
29.1
27.7
31.9
30.6
34.7
33.2
39.1
37.5
43.5
41.4
47.7
45.7
52.0
49.9
56.4
53.9
61.9
59.3
67.8
64.8
73.5
70.1
80.5
77.0
89.0
85.0
98.0
92.0
108
103
118
Maximum
Temperature
Coefficient
of V
(BR)
(% / °C)
0.057
0.057
0.061
0.061
0.065
0.065
0.068
0.068
0.073
0.073
0.075
0.075
0.078
0.078
0.081
0.081
0.084
0.084
0.086
0.086
0.088
0.088
0.090
0.090
0.092
0.092
0.094
0.094
0.096
0.096
0.097
0.097
0.098
0.098
0.099
0.099
0.100
0.100
0.101
0.101
0.101
0.101
0.102
0.102
0.103
0.103
0.104
0.104
0.104
0.104
0.105
0.105
0.105
+ Underwriters Laboratory Recognition for the classification of protectors (QVGQ2) under the UL standard for safety 497B and file number E136766
for both uni-directional and bi-directional devices
www.vishay.com
2
Document Number 88369
09-Oct-02
P6KE Series
Vishay Semiconductors
formerly General Semiconductor
Electrical Characteristics
Ratings at 25°C ambient temperature unless otherwise specified.
Breakdown Voltage
V
(BR)
at I
T
(1)
(V)
Device Type
+P6KE82A
+P6KE91
+P6KE91A
+P6KE100
+P6KE100A
+P6KE110
+P6KE110A
+P6KE120
+P6KE120A
+P6KE130
+P6KE130A
+P6KE150
+P6KE150A
+P6KE160
+P6KE160A
+P6KE170
+P6KE170A
+P6KE180
+P6KE180A
+P6KE200
+P6KE200A
+P6KE220
+P6KE220A
+P6KE250
+P6KE250A
+P6KE300
+P6KE300A
+P6KE350
+P6KE350A
+P6KE400
+P6KE400A
+P6KE440
+P6KE440A
P6KE480
P6KE480A
P6KE510
P6KE510A
P6KE540
P6KE540A
Min
77.9
81.9
86.5
90.0
95.0
99.0
105
108
114
117
124
135
143
144
152
153
162
162
171
180
190
198
209
225
237
270
285
315
333
360
380
396
418
432
456
459
485
486
513
Max
86.1
100
95.5
110
105
121
116
132
126
143
137
165
158
176
168
187
179
198
189
220
210
242
231
275
263
330
315
385
368
440
420
484
462
528
504
561
535
594
567
Test
Current
I
T
(mA)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Stand-off
Voltage
V
WM
(V)
70.1
73.7
77.8
81.0
85.5
89.2
94.0
97.2
102
105
111
121
128
130
136
138
145
146
154
162
171
175
185
202
214
243
256
284
300
324
342
356
376
389
408
413
434
437
459
Maximum
Reverse
Leakage
at V
WM
I
D
(µA)
(3)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Maximum
Peak Pulse
Current
I
PPM
(A)
(2)
5.3
4.6
4.8
4.2
4.4
3.8
3.9
3.5
3.6
3.2
3.4
2.8
2.9
2.6
2.7
2.5
2.6
2.3
2.4
2.1
2.2
1.7
1.8
1.7
1.7
1.4
1.4
1.2
1.2
1.0
1.1
0.95
1.0
0.88
0.91
0.82
0.86
0.78
0.81
Maximum
Clamping
Voltage at
I
PPM
V
C
(V)
113
131
125
144
137
158
152
173
165
187
179
215
207
230
219
244
234
258
246
287
274
344
328
360
344
430
414
504
482
574
548
631
602
686
658
729
698
772
740
Maximum
Temperature
Coefficient
of V
(BR)
(% / °C)
0.105
0.106
0.106
0.106
0.106
0.107
0.107
0.107
0.107
0.107
0.107
0.108
0.108
0.108
0.108
0.108
0.108
0.108
0.108
0.108
0.108
0.108
0.108
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
Notes:
(1)
Pulse test: t
p
≤
50ms
(2) Surge current waveform per Fig. 3 and derate per Fig. 2
(3) For bidirectional types with V
WM
of 10 volts and less, the I
D
limit is doubled
(4) All terms and symbols are consistent with ANSI/IEEE C62.35
+ Underwriters Laboratory Recognition for the classification of protectors (QVGQ2) under the UL standard for safety 497B and file number E136766
for both uni-directional and bi-directional devices
Description
This P6KE TVS series is a low cost commercial product for use in applications where large voltage transients can permanently damage voltage-sensitive components.
The P6KE series device types are designed in a small package size where power and space is a consideration. They are characterized by their high surge capability,
extremely fast response time, and low impedance, (R
on
). Because of the unpredictable nature of transients, and the variation of the impedance with respect to these
transients, impedance, per se, is not specified as a parametric value. However, a minimum voltage at low current conditions (BV) and a maximum clamping voltage (Vc) at
a maximum peak pulse current is specified.
In some instances, the thermal effect (see Vc Clamping Voltage) may be responsible for 50% to 70%. of the observed voltage differential when subjected to high current
pulses for several duty cycles, thus making a maximum impedance specification insignificant.
In case of a severe current overload or abnormal transient beyond the maximum ratings, the Transient Voltage Suppressor will initially fail 'short' thus tripping the system's
circuit breaker or fuse while protecting the entire circuit. Curves depicting clamping voltage vs. various current pulses are available from the factory. Extended
I referred to many people's solutions, but I finally completed it by myself! It was a tortuous process, and sometimes I felt that I was very slow to warm up and learn things! But in the end, I succeed...
Quectel BC28 NB module cannot read SIM card---------Has anyone used Quectel BC28 NB module? The problem I am facing now is that the module often cannot read SIM card (telecom IoT card) and occasionall...
Does anyone know the circuit design of UHF RFID reader? I don't want a reader that uses a highly integrated reader chip (R1000/AS3991/PR9000...) to build the circuit. Please help!...
This program is written to simulate the serial port hardware mechanism. When used, a timed interrupt can be set with a time interval of 1/4 baud rate. The receiving function is called once for ea...[Details]
1. Overview
Will passive devices
produce nonlinear intermodulation distortion? The answer is yes! Although there is no systematic theoretical analysis, it has been found in engineerin...[Details]
Do you often have to add brake fluid to your car's brakes? The fact that you need to pump out the brake fluid to make sure there is no gas in the brake fluid line may not be done by the car owner h...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
For a long time, due to the limitation of hardware conditions, the display devices of traditional small handheld devices such as PDA are usually monochrome LCD, and the user interface is very simpl...[Details]
DSP (digital signal processor) is used more and more frequently in today's engineering applications. There are three main reasons for this: first, it has powerful computing power and is capable of ...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
Smart lighting control systems provide high controllability for various buildings and further enhance the level of green energy. They are the core products of energy conservation and digital techn...[Details]
With the continuous consumption of earth's energy and the scarcity of resources, the harm of greenhouse effect to human beings, and the serious pollution of the atmosphere to the earth, the intern...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
The traditional display screen using 51 single-chip microcomputer to control LED dot matrix has relatively simple functions. If it is to achieve diversified functions, it often takes a lot of time ...[Details]