EEWORLDEEWORLDEEWORLD

Part Number

Search

4A12P-1AH-12R5_11

Description
Surge Line Protection Module
File Size341KB,3 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet View All

4A12P-1AH-12R5_11 Overview

Surge Line Protection Module

*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
RoHS compliant* versions available
Overcurrent/lightning protection to TELCORDIA GR-1089 Issue 3
Typical application is secondary protection on telecom line cards
UL497A recognition
Thermal fuse links
Must be used in conjunction with a solid state primary protector, or a GDT primary protector
4A12P-1AH-12R5 - Surge Line Protection Module
Electrical Characteristics
Resistance Value ................................................................12.5 ohms
Resistance Tolerance ..................................................................±5 %
TCR ..................................................................................100 ppm/°C
Ratio Tolerance ........................................................................±0.5 %
Temperature Range...................................................-40 ºC to +85 ºC
Functional Characteristics @ 25
°C
(Continued)
Second Level Lightning Surge -
Resistor package must fail safely causing no fire, electrical, or
framentation hazard.
5000 Volts Peak, 500 Amp Peak Current,
Max. Rise/Min. Decay Time 2x10 µs:
Number of Pulses ...............................1 simultaneous each polarity
Second Level AC Power Fault -
Resistor package must fail safely causing no fire, electrical, or
framentation hazard. Device will fail prior to Bussman MDQ 1-6/10 A
fuse in series.
100 Vrms, 2.2 Amp Short Circuit Current:
Duration...........................................................................15 minutes
600 Vrms, 7 Amp Short Circuit Current:
Duration............................................................................5 seconds
250 Vrms, 25 Amp Short Circuit Current:
Duration...........................................................................15 minutes
600 Vrms, 60 Amp Short Circuit Current:
Duration............................................................................5 seconds
Physical Characteristics
Body Style ...........................................Dual In Line SMD - Twin Pack
Substrate Material ........................................................96 % Alumina
Lead Frame Material........................................Copper, solder coated
Flammability .....................................................Conforms to UL94V-0
Processability................Unit is only suitable for no-clean processing
Convection Reflow...................Unit will withstand 260 °, 20 seconds
Packaging............16 inch diameter reels, 44 mm tape, 250 pcs./reel
Functional Characteristics @ 25
°C
(per Telcordia GR-1089 Issue 3)
First Level Lightning Surge -
Resistors will remain within tolerance after testing.
1000 Volts Peak, 100 Amp Peak Current,
Max. Rise/Min. Decay Time 10x1000 µs,
60 Seconds Between Pulses:
Number of Pulses ..............................25 each resistor each polarity
2500 Volts Peak, 500 Amp Peak Current,
Max. Rise/Min. Decay Time 2x10 µs,
60 Seconds Between Pulses:
Number of Pulses .............................10 simultaneous each polarity
Meets Protection Coordination as defined in Telcordia Section
4.6.7.1, Condition A.
First Level AC Power Fault -
Resistors will remain within tolerance after testing.
Product Dimensions
TOP VIEW
40.64 ± .25
(1.600 ± .010)
24
22
19 18
15
13
1
3
6
7
10
12
SIDE VIEW
5.28 ± .013
(0.208 ± .005)
50 Vrms, 0.33 Amp Short Circuit Current:
Duration...........................................................................15 minutes
100 Vrms, 0.17 Amp Short Circuit Current:
Duration...........................................................................15 minutes
600 Vrms, 1.00 Amp Short Circuit Current:
Duration.........................................................Sixty 1-second pulses
440 Vrms, 2.2 Amp Short Circuit Current:
Duration .........................................................Five 2-second pulses,
cooling to ambient between pulses
600 Vrms, 3.00 Amp Short Circuit Current:
Duration ......................................................Five 1.1-second pulses,
cooling to ambient between pulses
1
3
FRONT VIEW
12.70 ± .13
(0.500 ± .005)
14.10 ± .25
(0.555 ± .010
0.25
(0.010)
7.62 ± .13
(0.300 ± 0.005)
5.08 ± .13
(0.200 ± 0.005)
0.5
(0.020)
6.2 ± .25
(0.244 ± 0.010)
BOTTOM VIEW
6
7
10
12
1.68
(0.066)
2.31 ± .25
(0.091 ± .010)
2.49 ± .25
(0.098 ± .010)
7.11 ± .25
(0.280 ± .010)
24
22
19 18
15
13
DIMENSIONS:
MM
(INCHES)
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 767  403  410  2427  576  16  9  49  12  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号