EEWORLDEEWORLDEEWORLD

Part Number

Search

NPBMAN100PAUNV

Description
Basic Board Mount Pressure Sensors: NBP Series– Uncompensated/Unamplified
File Size407KB,8 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet View All

NPBMAN100PAUNV Overview

Basic Board Mount Pressure Sensors: NBP Series– Uncompensated/Unamplified

Basic Board Mount Pressure
Sensors: NBP Series–
Uncompensated/Unamplified
1 Bar to 10 Bar [15 psi to 150 psi]
DESCRIPTION
Honeywell’s Basic Board Mount Pressure Sensors: NBP
Series Uncompensated/Unamplified are designed for
customers who require a simple, cost-effective, basic
performance, mV output, unamplified, uncompensated, high
quality, high resolution solution for medical and industrial
applications.
These unamplified and uncompensated sensors offer infinite
resolution of the pressure signal. They will operate as specified
from -40 °C to 125 °C [-40 °F to 257 °F].
The NBP Series is ideal for those customers who want to do
their own compensation, calibration, and amplification in order
to make use of the maximum resolution of the bare sensor
output, leveraging a custom algorithm required for the
application.
VALUE TO CUSTOMERS
Cost-effective:
These devices provide a cost-effective
pressure sensing solution with a variety of options that
allow customers to meet their specific application needs
Honeywell brand:
Manufacturing excellence:
Honeywell has more than
100 years of manufacturing and engineering
excellence
Fast Request for Quotes (RFQs):
Responding
quickly to your RFQs and product sample needs is a
hallmark of Honeywell. Our experienced engineers
understand the importance of timely quotes. And
because Honeywell is a manufacturer, you can depend
on a quick response to your prototype needs.
Fast response for samples:
Dedicated teams and
manufacturing processes ensure that product samples
are shipped quickly and delivered in time to support
your demanding product development cycle
Additionally, the NBP Series offers several package styles and
mounting options, making it easier for device manufacturers to
integrate the product into their applications.
The NBP Series measures absolute and gage pressures. The
absolute versions have an internal vacuum reference and an
output value proportional to absolute pressure. Gage versions
are referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
The NBP Series sensors are intended for use with non-
corrosive, non-ionic gases, such as air and other dry gases
and for non-corrosive, non-ionic liquids. All products are
designed and manufactured according to ISO 9001.
Reliable supply chain:
Honeywell’s effective
inventory management and dependable supply chain is
there throughout your development cycle
Designed to Six Sigma standards:
Six Sigma
standards provide the highest level of product quality,
performance, and consistency. Six Sigma provides
confidence that the sensor will perform to specification.
Many competitive products are produced to lower
Sigma tolerances, which may result in some products
not performing to the specification to which they were
designed.
Supporting documentation:
Honeywell’s website
provides numerous technical materials to assist you in
your application needs
About serial communication (RS485)
I now have a slave board. If the slave board cannot receive data from the host within 3S, the baud rate will be switched from the default 9600 to 38400. If it still cannot receive data after another 3...
笨笨丁2018 Microcontroller MCU
Newbie asks: Data type and function issues when porting from VC to EVC
Hello everyone: I am a student who has just started working. The task I got is to port a library written in VC6.0 to EVC. The method I used was to paste the VC code into EVC and then find the error in...
sonic Embedded System
Why does asynchronous FIFO use Gray code?
The first thing to understand is that the only purpose of using Gray code in asynchronous FIFO is to "correctly determine the empty or full state even when sampling the read and write pointers in a me...
eeleader FPGA/CPLD
Shaanxi Province TI Electronic Competition Component List
2012 "TI Cup" Undergraduate Electronic Design Competition Basic instruments, main components and components provided by TI In addition to the laboratory instruments and components, this electronic des...
wow1919 TI Technology Forum
Teach you how to make a lithium battery fast charging charger
Teach you how to make a lithium battery fast charging charger Author: wcc149Source: WeChat Official Account - Electronic Circuit Development Learning Preface Recently, I found another open source embe...
okhxyyo Power technology
Transparent button problem under wince (with source code)
Dear passers-by, resident, and solution seekers, can anyone help me find out what is wrong with my code? I will be grateful! I will give you all the points I can get as a thank you! The same code is d...
znstchhh Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 982  1968  280  1287  686  20  40  6  26  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号