EEWORLDEEWORLDEEWORLD

Part Number

Search

LP49-18-FREQ1-30G3JH

Description
Parallel - 3Rd Overtone Quartz Crystal, 27MHz Min, 32MHz Max, ROHS COMPLIANT PACKAGE-2
CategoryPassive components    Crystal/resonator   
File Size92KB,6 Pages
ManufacturerPletronics
Environmental Compliance  
Download Datasheet Parametric View All

LP49-18-FREQ1-30G3JH Overview

Parallel - 3Rd Overtone Quartz Crystal, 27MHz Min, 32MHz Max, ROHS COMPLIANT PACKAGE-2

LP49-18-FREQ1-30G3JH Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPletronics
package instructionROHS COMPLIANT PACKAGE-2
Reach Compliance Codecompliant
Other featuresAT-CUT CRYSTAL; BULK
Ageing5 PPM/YEAR
Crystal/Resonator TypePARALLEL - 3RD OVERTONE
Drive level1000 µW
frequency stability0.003%
frequency tolerance30 ppm
JESD-609 codee3
load capacitance18 pF
Manufacturer's serial numberLP49
Installation featuresTHROUGH HOLE MOUNT
Maximum operating frequency32 MHz
Minimum operating frequency27 MHz
Maximum operating temperature75 °C
Minimum operating temperature-30 °C
physical sizeL10.8XB4.47XH3.56 (mm)/L0.425XB0.176XH0.14 (inch)
Series resistance100 Ω
surface mountNO
Terminal surfaceMatte Tin (Sn)
LP21 / LP24 / LP49 Series
Low Profile Crystal
February 2010
• The Pletronics’ LP49 Series is a low profile
thru-hole crystal
• Bulk packaging
• 3 MHz to 70 MHz
• HC-49/US
• AT Cut Crystal
LP21 0.082 (2.10mm) high
LP24 0.100 (2.50mm) high
LP49 0.140 (3.56mm) high
Pletronics Inc. certifies this device is in accordance with the
RoHS (2002/95/EC) and WEEE (2002/96/EC) directives.
Pletronics Inc. guarantees the device does not contain the following:
Cadmium, Hexavalent Chromium, Lead (<1000 ppm), Mercury, PBB’s, PBDE’s
Weight of the Device: 0.62 grams
Moisture Sensitivity Level: 1 As defined in J-STD-020C
Second Level Interconnect code: e1, e2 or e3
Electrical Specification:
Item
Frequency Range
Calibration Frequency Tolerance
Frequency Stability over OTR
Equivalent Series Resistance
(ESR)
Min
3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Drive Level
Shunt Capacitance
Aging per year
Specified Temperature Range
Storage Temperature Range
(C0)
-
-
-5
-40
-55
Max
70
-
-
200
150
120
100
80
70
60
50
40
35
100
80
60
1
7
+5
+85
+125
Unit
MHz
ppm
ppm
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
Ohms
mW
pF
ppm
o
o
Condition
AT cut
at +25
o
C + 3
o
C
_
see table on page 3 for
available options
LP49
LP49/LP24
LP49/LP24
LP49/LP24
LP49/LP24
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
LP49/LP24/LP21
3
rd
Overtone
Fundamental
3 MHz to 4 MHz
4 MHz to 5 MHz
5 MHz to 6 MHz
6 MHz to 7 MHz
7 MHz to 9 MHz
9 MHz to 10 MHz
10 MHz to 13 MHz
13 MHz to 15 MHz
15 MHz to 27 MHz
27 MHz to 30 MHz
27 MHz to 32 MHz
32 MHz to 50 MHz
50 MHz to 70 MHz
use 10 µW for testing
Pad to Pad capacitance
at +25
o
C + 3
o
C
_
see table on page 3 for available options
C
C
Product information is current as of publication date. The product conforms
to specifications per the terms of the Pletronics limited warranty. Production
processsing does not necessarily include testing of all parameters.
Copyright © 2010, Pletronics Inc.
Research on Simulation of Spaceborne Synthetic Aperture Radar Data
Abstract Aiming at the simulation of raw echo data of spaceborne SAR, a satellite attitude disturbance model is established, and a range migration correction method is proposed. Simulation results of ...
JasonYoo Embedded System
MSP430 Program Library --- 12864 LCD Program Library
Hardware introduction:430 digital IO port: MSP430F149 and MSP430F169 both have P1-P6, each 8 bits, for a total of 48 IO ports; there are a large number of IO ports available, so the 8-bit parallel dat...
灞波儿奔 Microcontroller MCU
Errors that occur when the ISR in Kernel mode is interrupted
I have a question for the experts: When I use Windriver to write the ISR interrupt in kernel mode, the following error occurs when linking the framework generated by windriver: error LNK 2026: module ...
mooddog Embedded System
v/f conversion, please help me analyze the operating principle
As shown in the figure, I want to get the measured value of the thermocouple. How can I calculate it? Which instrument manufacturer can teach me the operating principle? Thank you...
帝国斜阳$ MCU
Smart watches, a carnival for brain-dead geeks
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:51[/i]   It is true that all manufacturers now deal with the relationship between mobile phones and smart watches in the form of access...
shunzhou Mobile and portable
Resistor Knowledge Encyclopedia (E-book).rar
Resistor Knowledge Encyclopedia (E-book).rar...
Understand_Lin MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2169  2881  968  1838  1408  44  58  20  38  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号