HGN-375C01S-17-1MM3

Description
Mains Power Connector, 1A, 125/250VAC, Male, Solder Terminal, Socket
CategoryThe connector    The connector   
File Size485KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

HGN-375C01S-17-1MM3 Overview

Mains Power Connector, 1A, 125/250VAC, Male, Solder Terminal, Socket

HGN-375C01S-17-1MM3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings1A, 125/250VAC
Manufacturer's serial numberHGN-375
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
HGN-375(A, B, C)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS
(Unit: mm)
CASE A
49.83
60.71
55.04
65.4
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
60.0
O
32.45
-
40 + 0.2
3.5
49.37
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
28.5
4x R0.5
6.30 TYP.
-
40.0+ 0.2
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
2x 3.5
29.3
+0.5
60.8
+0.5
72.0
+0.1
29 6.3 TYP.
29.5
59.8
48.7
(3.5)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
CASE C
(61.3)
(56.2)
TECHNICAL DATA
Rated Voltage: 125/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2
µ
A*, max
@ 250VAC 50Hz: 5
µ
A*, max
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
48.7
(3.5)
R2.5 TYP.
29.3
+0.5
29 6.3 TYP.
61.4
+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
81
Selection of UAV flight control, gimbal stabilization, and image transmission modules
1. Flight control The flight control system of a drone refers to a control system that can stabilize the flight attitude of a drone and can control the autonomous or semi-autonomous flight of a drone....
qwqwqw2088 Analogue and Mixed Signal
Application of AT89051 single chip microcomputer in medical instruments
This paper describes the design concept, basic structure, functions and some important technical indicators of the test strip tester which uses the single chip microcomputer AT89C5 as the core. Throug...
soso Medical Electronics
The engineer said: It is better to plan the number of PCB design wiring layers than to plan your life!
The end of 2016 sounded the alarm. Planning is a word that has been very popular in different stages of our lives. So far, we cannot abandon it and live alone. When you are in high school, your parent...
kdyhdl PCB Design
Dimensioning and setting of Drill layer in PCB design
[align=left][size=14px][color=rgb(34, 34, 34)][font="][size=16px]In this issue, we have sorted out the dimensioning and settings of the Drill layer in PCB design, hoping to be helpful to everyone. [/s...
板儿妹0517 PCB Design
TI's C6455 connection problem
Dear seniors, can the reset signal time of DSP be too long? Is the ripple value of 200mV of 1.2V core voltage considered large? Just can't connect to the emulator, I don't know what the problem is. Er...
duolakk DSP and ARM Processors
Power module viewing operation
[Ask if you don't understand] AD2018 version, I see this module in the schematic diagram, which is an integrated circuit diagram that cannot be modified. How can I click from this module to see the in...
shaorc PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2868  2541  352  2771  2688  58  52  8  56  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号