Monitoring and
Control Devices
7
7/102
7/105
7/108
Ch. 6
3TK28 Safety Relays
With electronic enabling circuits
With relay enabling circuits
With contactor relay enabling circuits
3RA71 load feeders
with integrated safety functions
Interface Converters
3RS17 interface converters
7/112
1) See Catalog IK PI · 2005
"Industrial Communication for
Automation and Drives"
7/2
Introduction
SIMOCODE 3UF Motor
Management and Control Devices
SIMOCODE pro 3UF7 motor
management and control devices
SIMOCODE-DP 3UF5 motor protection
and control devices
3UF18 current transformers
for overload protection
3UL22 summation current
transformers
LOGO! Logic Modules
General data
LOGO! Modular basic variants
LOGO! Modular pure variants
LOGO! Modular extension modules
LOGO! Modular communications
modules
AS-Interface connection for LOGO!
LOGO!Contact
LOGO! Software
3RP, 7PV Timing Relays
General data
3RP15 timing relays
in industrial enclosure, 22.5 mm
3RP20 timing relays, 45 mm
7PV timing relays for panel mounting
3RT19 timing relays
for mounting to contactors
Monitoring Relays
3UG Monitoring Relays
for Electrical and Additional
Measurements
Line monitoring
Voltage monitoring
Current monitoring
Power factor monitoring
Insulation monitoring
for ungrounded AC networks
Insulation monitoring
for ungrounded DC networks
Level monitoring
Speed monitoring
3RS10, 3RS11 Temperature Monitoring
Relays
General data
Relays, analog adjustable
Relays, digitally adjustable to
DIN 3440
Relays, digitally adjustable
for up to 3 sensors
3RN1 Thermistor Motor Protection
For PTC sensors
7/5
7/26
7/35
7/40
7/41
7/42
7/43
IK PI
1)
IK PI
1)
IK PI
1)
IK PI
1)
7/44
7/45
7/49
7/55
7/58
7/60
7/63
7/69
7/73
7/76
7/78
7/80
7/82
7/85
7/87
7/90
7/92
7/94
7/96
Siemens LV 1 T · 2006
7
Monitoring and Control Devices
Introduction
■
Overview
The advantages at a glance
3UF7
3UF5
Order No.
6ED1 052
Page
7/5
7/26
SIMOCODE 3UF motor management and control devices
SIMOCODE pro 3UF7
SIMOCODE-DP 3UF5
• Compact, modular design
3UF7
• Unique flexibility in terms of functionality and hardware
3UF5
configuration
• Wide functional range from the distributed I/O system to the
autonomous motor management system
• All control functions from the direct starter to the pole-
changing switch with reversing contactor
• All motor sizes
• Integration in all PROFIBUS-capable automation systems
• Application in low-voltage controlgear for motor control
centers on the process industry
• Increases plant availability
• Saves costs during construction, commissioning and
operation of the plant
• Extensive data of the motor feeder available everywhere on
the PROFIBUS
• All protection, monitoring and control functions for the motor
feeder in a single system
• Protection converter for activating overload relays or for use
with SIMOCODE pro
• Ensures proportional current transfer up to a multiple of the
primary rated current
• Senses fault currents in machines and plants
• Senses ground fault currents
• Compact, user-friendly and low-cost solution for simple
control tasks
• Universal:
- Building installation and wiring (lighting, shutters,
awnings, doors, access control, barriers, ventilation
systems ...)
- Control cabinet installation
- Machine and device construction (pumps, small presses,
compressors, hydraulic lifts, conveyors ...)
- Special controls for conservatories and greenhouses
- Signal preprocessing for other controllers
• Flexible expansion depending on the application
• With display, pushbuttons and an interface for connecting
extension modules
• Without display and pushbuttons but with an interface for
connecting extension modules
• For connection to LOGO! Modular basic variants with
digital inputs and outputs or analog inputs and outputs
6ED1 052-1
6ED1 052-2
6ED1 055-1
7/42
7/43
3UF18
3UF18 current transformers for overload
protection
7/35
3UL22 summation current transformers
3UL22
7/40
LOGO! logic modules
LOGO! logic modules
7
LOGO! Modular basic variants
LOGO! Modular pure variants
LOGO! Modular extension modules
LOGO! Modular communications modules
LOGO!Power
IK PI
1)
IK PI
1)
IK PI
1)
IK PI
1)
7/44
• For integrating LOGO! in an
instabus
KNX
EIB
system or as 3RK1 400
an AS-Interface slave
• Power supply for converting the supply voltage of
100 ... 240 V AC into an operational voltage of 24 V DC or
12 V DC
• Switching module for switching resistive loads and motors
directly
• For switchgear program generation on the PC
6EP1 3
LOGO!Contact
LOGO! Software
6ED1 057-4
6ED1 058
1) See Catalog IK PI · 2005 "Industrial Communication for Automation and
Drives"
7/2
Siemens LV 1 T · 2006
Monitoring and Control Devices
Introduction
The advantages at a glance
3RP
7PV
3UG45 11
Order No.
Page
7/49
3UG46 14
3RP, 7PV timing relays
3RP15 timing relays in industrial enclosure,
22.5 mm
• Low-cost solution with monofunctions such as response
delay, off-delay, clock-pulse, wye-delta function and
multifunction
• Wide-range voltage designs
• The solution for small mounting depths
• The low mounting height reduces the tier spacing
• Digital variant
3RP15
3RP20 timing relays, 45 mm
7PV timing relays for panel mounting
3RP20
7PV
3RT19
7/55
7/58
7/60
3RT19 timing relays for mounting onto contactors
• Saves space because the relay is mounted onto the
contactor
• Wiring advantages thanks to direct contacting
with contactor
3UG monitoring relays for electrical and additional measurements
Line monitoring
Phase sequence
Phase sequence, phase failure, phase unbalance
Phase sequence, phase failure, phase unbalance
and undervoltage
• Low-cost solution for monitoring the phase sequence
• Wide voltage range from 160 ... 690 V
• Analog adjustable
• Wide voltage range from 160 ... 690 V
• Digitally adjustable with LCD display for indication of
ACTUAL value and device status
• Wide voltage range from 160 ... 690 V
Phase sequence, phase failure, phase unbalance
and overvoltage and undervoltage
Phase sequence, phase and N conductor failure,
phase unbalance, overvoltage and undervoltage
Automatic correction of the direction of rotation in
case of wrong phase sequence, phase failure,
phase unbalance, overvoltage and undervoltage
Automatic correction of the direction of rotation in
case of wrong phase sequence, phase and
N conductor failure, phase unbalance, overvoltage
and undervoltage
Voltage monitoring
Voltage monitoring with internal power supply for
• Digitally adjustable with LCD display for indication of
overvoltage and undervoltage
ACTUAL value and device status
• Wide measuring ranges
Voltage monitoring with auxiliary voltage for
• Variant for wide voltage range
overvoltage and undervoltage
Current monitoring
Current monitoring with auxiliary voltage for
overvoltage and undervoltage
• Digitally adjustable with LCD display for indication of
ACTUAL value and device status
• Wide measuring ranges
• Variant for wide voltage range
• Upper and lower threshold value can be adjusted
separately
3UG46 21/22
7/73
3UG46 33
3UG46 31/32
7/69
7/70
• Digitally adjustable with LCD display for indication of
ACTUAL value and device status
• Wide voltage range from 160 ... 690 V
3UG45 11
3UG45 12
3UG45 13
3UG46 14
7/63
7/63
7/64
7/64
3UG46 15
3UG46 16
3UG46 17
7/65
7/65
7/65
3UG46 18
7/65
Power factor monitoring (motor load monitoring)
Monitoring relay for overshoot and undershoot
monitoring with internal power supply
(window monitoring)
Insulation resistance
Monitoring of the insulation resistance for
• Test button
ungrounded AC or DC networks from 10 ... 110 k
W
• With or without memory
• Switchable measuring range
Level monitoring
Fill level and resistance
• As single-step or two-step controls for inlet or outlet
monitoring of conducting liquids or as
resistance threshold switch
• Variable, wide range from 5 ... 100 k
W
• UNDER/OVER adjustable
•
•
•
•
•
3UG35 01
7/82
3UG30 81,
3UG30 82
7/78
3UG30 14
7/76
Speed monitoring
Underspeed monitoring
Together with a sensor for monitoring continuous pulses
3UG30 51
With or without memory
Adjustable ON delay
1, 2 and 3 changeover contacts
Hard gold-plated contacts in combination and wide voltage
range versions
7/85
Siemens LV 1 T · 2006
7/3
7
Monitoring and Control Devices
Introduction
The advantages at a glance
3RS10
3RN1
3TK28
Order No.
Page
3RS17
3RS10, 3RS11, 3RS20 temperature monitoring relays
For monitoring the temperatures of solids, liquids, and gases
Relays, analog adjustable
•
•
•
•
Separate versions for overshoot and undershoot
For simple monitoring tasks
For PT100 or thermoelements J and K
Variable hysteresis
3RS10,
3RS11
7/90
Relays, digitally adjustable acc. to DIN 3440
• For two-step or three-step controls
• For monitoring heat generation plants
• For PT100/1000, KTY83/84, NTC or thermoelements
type J, K, T, E, N, R, S, B
3RS10,
3RS11,
3RS20
7/92
Relays, digitally adjustable for up to 3 sensors
3RS10
• For simultaneously monitoring several sensors
• Especially suited for monitoring motor winding temperatures
• For PT100/1000, KTY83/84, NTC
• Relays for monitoring motor winding temperatures with
3RN1
type A PTC sensors
• Integrated with ATEX license
• Closed-circuit principle
• Depending on the version: With short-circuit and open-circuit
detection, zero voltage safety, manual/auto/remote RESET,
1 CO, 1 NO + 1 NC, 2 CO, 1 NO + 1 CO or 2 CO
hard gold-plated
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Permanent function checking
No wear because switched electronically
High switching frequency
Long electrical endurance
Evaluation of solid-state sensors
Sensor lead up to max. 2000 m
Cascading possible
Insensitive to vibrations and dirt
Compact design, low weight
Approved for the world market
Compact design
Floating safe outputs
Also suitable for press and punch controls
Can be used up to an ambient temperature of max. 70 °C
3TK28 4
7/94
3RN1 thermistor motor protection
For PTC sensors
7/96
3TK28 safety relays
With electronic enabling circuits
7/102
With relay enabling circuits
3TK28 2, 3TK28 3
7/105
7
With contactor relay enabling circuits
3TK28 5
Floating enabling circuits
AC-15/DC-13 switching capacity
Safe isolation
Long mechanical and electrical endurance
Certified as a complete unit
Fault minimization and cost reduction through factory wiring
Low installation costs
Available in fused or fuseless configuration
Floating enabling circuits
AC-1/AC-3 switching capacity
Certified as a complete unit
Long mechanical and electrical endurance
Rated operational voltage up to 690 V
Safe isolation
3TK28 5
7/108
3RA71 load feeders
with integrated safety functions
Ch. 6
3RS17 interface converters
Converters for standard signals and
non-standard variables
• All terminals protected against polarity reversing and
overvoltage up to 30 V
• For electrical isolation and conversion of analog signals
• Short-circuit resistant outputs
• From 6.2 mm width
• Switchable multi-range converters
• Variants with manual/automatic switch for setpoint input or
for the conversion of analog variables into frequency
3RS17
7/112
7/4
Siemens LV 1 T · 2006
SIMOCODE 3UF Motor Management and Control Devices
SIMOCODE pro 3UF7
motor management and control devices
■
Overview
SIMOCODE pro is a flexible, modular motor management sys-
tem for motors with constant speeds in the low-voltage perfor-
mance range. It optimizes the connection between I&C and
motor feeder, increases plant availability and allows significant
savings to be made for startup, operation and maintenance of a
system.
When SIMOCODE pro is installed in the low-voltage switchgear
cabinet, it is the intelligent interface between the higher-level
automation system and the motor feeder and includes the
following:
• Multifunctional, solid-state full motor protection which is
independent of the automation system
• Flexible software instead of hardware for the motor control
• Detailed operational, service and diagnostics data
• Open communication through PROFIBUS DP, the standard for
fieldbus systems
■
Design
General
SIMOCODE pro is a modularly constructed motor management
system which is subdivided into two device series with different
functional scopes:
• SIMOCODE pro C
• SIMOCODE pro V
Both series (systems) are made up of different hardware
components (modules):
System
Modules
SIMOCODE pro C
• Basic unit 1
• Current measuring module
SIMOCODE pro V
• Basic unit 2
• Current measuring module or
current/voltage measuring
voltage
• Operator panel (optional)
• Expansion modules
(optional)
• Operator panel (optional)
Per feeder each system always comprises one basic unit and
one separate current measuring module. The two modules are
connected together electrically through the system interface
with a connection cable and can be mounted mechanically
connected as a unit (one behind the other) or separately (side
by side). The motor current to be monitored is decisive only for
the choice of current measuring module.
An operator panel for mounting in the control cabinet door is
optionally connectable through a second system interface on
the basic unit. Both the current measurement module and the
operator panel are electrically supplied by the basic unit through
the connection cable. More inputs, outputs and functions can be
added to basic unit 2 (SIMOCODE pro V) by means of optional
expansion modules, thus supplementing the inputs and outputs
already existing on the basic unit.
All modules are connected together by connection cables.
The connection cables are available in various lengths. The
maximum distance between the modules (e.g. between the
basic unit and the current measurement module) must not
exceed 2 m. The total length of all the connection cables in a
single system must not be more than 3 m.
SIMOCODE pro designed for mixed operation
Depending on functional requirements, the two systems can be
used simultaneously without any problems and without any addi-
tional outlay in a low-voltage system. SIMOCODE pro C is fully
upward-compatible to SIMOCODE pro V. The same compo-
nents are used. The parameterization of SIMOCODE pro C can
be transferred without any problems. Both systems have the
same removable terminals and the same terminal designations.
Siemens LV 1 T · 2006
7/5
7