EEWORLDEEWORLDEEWORLD

Part Number

Search

LTGLO41B-TW-B-R/6V

Description
Rocker Switch, DPST, Momentary, Quick Connect Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size112KB,1 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

LTGLO41B-TW-B-R/6V Overview

Rocker Switch, DPST, Momentary, Quick Connect Terminal, Rocker Actuator, Panel Mount

LTGLO41B-TW-B-R/6V Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width25.24 mm
body height20.62 mm
Body length or diameter28.45 mm
Contact (AC) maximum rated R load10A@125VAC
Maximum contact current (AC)10 A
Maximum contact voltage (AC)125 V
Electrical life25000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial numberLTG
Installation featuresPANEL MOUNT
Maximum operating temperature66 °C
Minimum operating temperature
surface mountNO
Switch actionMOMENTARY
switch functionDPST
Switch typeROCKER SWITCH
Termination typeQUICK CONNECT
Carling
Technologies
TG/LTG-Series Rocker Switches
TG/LTG-Series Rocker Switches
The TG-Series Mini Tippette rocker switches are single or
double pole and feature an all nylon double-insulated con-
struction. These switches are designed with snap-in mount-
ing for fast, low cost assembly. The illuminated version
(LTG) is available with either a paddle or rocker actuator.
These AC rated switches are also suitable for low-voltage
DC applications in a wide range of markets including
Appliance, HVAC, Food service, and Transportation.
Dielectric Strength
UL/CSA:
1000V - live to dead metal parts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 150°F (0°C to +65.6°C)
.069[1.75] DIA
.156[3.96] DIA
.055[1.40] DIA
6.000[152.40]
.375[9.52]
.250[6.35]
.500[12.70]
1.155[29.33]
.865[21.97]
.050[1.27]
1.240[31.50]
.250[6.35]
.250 TAB (Q.C.)
.250[6.35]
SOLDER LUG
.187[4.74]
.187 TAB (Q.C.)
INTEGRATED WIRE LEAD
(no exposed conductors)
TERMINAL TYPE
.210[5.33]
.812[20.62]
.520[13.20]
1.125[28.57]
.375[9.52]
1.120[28.45]
PADDLE
1.000[25.40]
.994[25.24]
MOUNTING HOLE
Panel Thickness:
.030[.762] min. to
.250[6.35] max.
LTG G O 50 1
-
T B
-
B
-
R
/
125N
1
Base Part Number
2
Circuit
3
Center
Position
4
Rating
5
Termination
6
Actuator
Style
7
Actuator
Color
8
Base Color
9
Lens Color
10
Lamp
Voltage
1 BASE PART NUMBER: SERIES
1
TG
Double Pole, Non-Lighted
LTG
Double Pole with Indicator Lights
2 CIRCUIT
See Circuit Designation Chart Page 17.
3 CENTER POSITION
C
Center OFF, Three position
O
No Center OFF, Two position
4 RATING
40
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
41
5A 250VAC, 10A 125VAC
50
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
51
10A 250VAC, 15A 125VAC
5 TERMINATION/FUNCTION
solder lug
ON-NONE-OFF
0
(ON)-NONE-OFF
A
ON-NONE-(OFF)
L
ON-NONE-ON
0
ON-NONE-(ON)
A
ON-OFF-ON
0
6 ACTUATOR STYLE
P
paddle
7 ACTUATOR COLOR
2
B
black
8 BASE COLOR
2
B
black
9 LENS COLOR
3
A
amber
10 LAMP VOLTAGE
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
wire leads
5
F
T
5
F
5
T
rocker
W
white
W
white
C
clear
R
red
neon
125N
125 volt neon
250N
250 volt neon
.250 tab QC
1
B
M
1
B
1
.187 tab QC
3
D
R
3
D
3
NOTES
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same direction as the punch. (Burr on bottom.) Test cut hole in actual material.
1
TG available with circuits A, B, C, D, E, F ; LTG available with circuits G, H, I, J, M, N, P, Q, R, T, U, V, Y, Z. See page 17.
2
Custom colors are available. Consult factory.
3
Specify lens color for LTG-Series only.
()
Indicates momentary function.
14
www.carlingtech.com
Sampling time in the official guidance document of Hot Wheels
Capacitive Touch BoosterPack (430BOOST-SENSE1) for the LaunchPad User's Guide (Rev. B) slau337b 第15页 The User Experience application starts in sleep mode, sampling the proximity sensor approximately e...
wangfuchong Microcontroller MCU
Desktop power supply interference problem
Several power supplies are used in the same room, including a Xinma Gold 500w, a Maexs Gold 500w, and several Great Wall Huntkey 350w power supplies. Symptoms: The original power supplies were very qu...
kamisama233 Power technology
Looking for DK3200 development kit at a high price. (Second hand also available)
Due to project limitations, I have to use UPSD3234A-40U6 for development. I am not familiar with it, so I got a development board to get familiar with it.It is difficult for me to find a new one. If a...
ysc_54188 stm32/stm8
ECG dedicated chip ADAS1000
The ADAS1000-3/ADAS1000-4 measures electrocardiogram (ECG) signals, chest impedance, pacing artifacts, and lead connection/detachment status, and outputs this information in the form of a data frame, ...
dontium ADI Reference Circuit
How to set the ROM size in quartusII?
I have a 4k rom size, but now I want to change it to 8k because the program is larger than 4k. I changed the address lines and related configurations, but the program (about 5k) does not run properly ...
zhouzhaofu Embedded System
Temperature and humidity controller
My girlfriend wants to build a temperature and humidity control system for the greenhouse, but she doesn't know how to start. Does anyone have any information on this, circuit diagrams, coding, etc.? ...
wuxiangyun Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2349  697  1048  1119  2821  48  15  22  23  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号