EEWORLDEEWORLDEEWORLD

Part Number

Search

LK5320-9DDTB2

Description
AC-DC Power Factor Correction Module, 2 Output, 150W, HEAT SINK, METAL, CASE K02
CategoryPower/power management    The power supply circuit   
File Size1MB,28 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LK5320-9DDTB2 Overview

AC-DC Power Factor Correction Module, 2 Output, 150W, HEAT SINK, METAL, CASE K02

LK5320-9DDTB2 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel Fuse
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-XXMA-X
JESD-609 codee0
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage12.07 V
Minimum output voltage11.93 V
Nominal output voltage12 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputNO
Rugged Environment
AC-DC Converters >100 Watt
K Series
150 Watt AC-DC Converters with PFC
Input to output isolation
Single output: LK 4000 5.1, 12, 15, 24 V
Double output: LK 5000 2
×
12, 2
×
15, 2
×
24 V
Universal input voltage range
Power factor
>0.95,
harmonics
<IEC/EN
61000-3-2
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
4 kV
rms
input to output electric strength test
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
C
K-Series
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Summary
The K 4000/5000-series of AC-DC converters represents a
flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified ranges. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected with pin 14 to en-
able the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19 inch rack sys-
tems according to DIN 41494, or be chassis mounted.
Important:
These products are intended to replace the
LK 1000 and LK 2000 in order to comply with IEC/EN
61000-3-2.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 16
Immunity to Environmental Conditions ........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options .................................................... 22
Accessories .................................................................... 28
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 12
MELCHER
The Power Partners.
Edition 4/4.99
1/28
Calculation of stator flux
What is the calculation formula based on stator flux? Can anyone who works on inverters tell me about it?...
eeleader Industrial Control Electronics
Request information
Information on studying God-given embedded system programming...
无理由 Programming Basics
The pros and cons of interrupting dog feeding!
I have seen many posts on the website that suggest not to feed the dog in the interrupt program. Most people's reason is that the interrupt will not necessarily "die" if the program runs away. But if ...
chenky Embedded System
2011 National Undergraduate Electronic Design Competition Training-Basic Skills
[i=s] This post was last edited by paulhyde on 2014-9-15 03:00 [/i] It contains 2011 National Undergraduate Electronic Design Competition Training - Basic Skills and 2011 National Undergraduate Electr...
谷粒朱古力 Electronics Design Contest
Bit operations that can be used to show off (transferred)
Hacker's Delight The Secret of Efficient Programming and this article from Stanford, it's hard not to show off when using bit operations http://graphics.stanford.edu/~seander/bithacks.htmlBit Twiddlin...
白丁 Integrated technical exchanges
What’s wrong with the TIM4 query program?
#include "iostm8L152k4.h" main() { // First initialize GPIO PD_DDR = 0x08; PD_CR1 = 0x08; // Set PD3 to push-pull output PD_CR2 = 0x00; // Then initialize timer 4 TIM4_IER = 0x00; TIM4_EGR = 0x01; TIM...
suzhiqiang168 stm32/stm8

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2786  1004  2009  2630  2333  57  21  41  53  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号