EEWORLDEEWORLDEEWORLD

Part Number

Search

55246WA-13X433UL-CSAU1044

Description
Toggle Switch, DPDT, Latched, Solder Terminal, Lever Actuator, Through Hole-right Angle
CategoryMechanical and electronic products    switch   
File Size163KB,3 Pages
ManufacturerAPEM
Environmental Compliance  
Download Datasheet Parametric View All

55246WA-13X433UL-CSAU1044 Overview

Toggle Switch, DPDT, Latched, Solder Terminal, Lever Actuator, Through Hole-right Angle

55246WA-13X433UL-CSAU1044 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeLEVER
body width13 mm
body height12 mm
Body length or diameter13.2 mm
Contact (AC) maximum rated R load6A@125VAC
Maximum contact current (AC)6 A
Maximum contact voltage (AC)125 V
Manufacturer's serial number55000
Installation featuresTHROUGH HOLE-RIGHT ANGLE
sealEPOXY TERMINAL SEALED
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typeTOGGLE SWITCH
Termination typeSOLDER
55000 series
VDE approved toggle switches
• The switches described below are marked VDE as standard.
EN 61058-1
• UL and CSA agency approvals are also available. To order a switch marked
UL or CSA, please complete “Other agency approvals" box.
A
ELECTRICAL SPECIFICATIONS
MATERIALS
• Class I (normal insulation)
• Small contact opening : µ (< 3 mm (.118))
• Current/voltage rating with resistive load : 3A 250VAC - 6A 125VAC
• Dielectric strength :
2.000 Vrms 50 Hz min. between poles and between terminals and frame
1.000 Vrms 50 Hz min. between terminals
• Special body for increased creepage distance and air gap : 3 mm (.118)
GENERAL SPECIFICATIONS
• Contacts : silver
• Case : diallylphthalate (DAP)
• Actuator : brass, chrome plated
with insulating vinyl cap
• Bushing : brass, nickel plated
• Housing : stainless steel
• Terminal seal : epoxy
Further specifications, see 5000 series.
• Insulating cap, compulsory, supplied glued on the lever :
U270 for models 55600A, 55200A and 55200ZA
U1040 for models 55200WA and 55200WA X433
• Ground connector :
U721 compulsory if the panel is not metallic or not connected to ground
• Epoxy sealed terminals standard
MODEL
STRUCTURE
Solder lugs
III
2-3
5-6
Single pole Double pole
55636A
55639A
55646A
55649A
ON
ON
-
OFF
ON
ON
II
I
1-2
4-5
Keyway
Ø6.35-40UNS
(1/4-40UNS)
III
II
24˚
I
Ø4.00
(.157 DIA)
11.50
(.452)
8.00
(.314)
1.00
(.039)
12.00
(.472)
11.00
(.433)
7.00
(.275)
4.70
(.185)
13.20
(.519)
3.70
(.145)
1.80
(.070)
2.00
(.078)
1
2
3
12.00
(.472)
4.75
(.187)
EPOXY
Also available with Ø 6 mm (.236) bushing :
55500.
Straight PC terminals
III
2-3
5-6
Single pole Double pole
55236A
55239A
55246A
55249A
ON
ON
-
OFF
ON
ON
II
I
1-2
4-5
Keyway
4.70
(.185)
Ø1.60
(.062 DIA)
Ø6.35-40UNS
(1/4-40UNS)
III
II
24˚
I
Ø4.00
(.157 DIA)
11.50
(.452)
13.30
(.523)
8.00
(.314)
1.00
(.039)
4.00
(.157)
3.30
(.129)
14.00
(.551)
11.00
(.433)
2.00
(.078)
1
2
3
4.70
(.185)
4.75
(.187)
12.00
(.472)
1.10
(.043)
7.00
(.275)
EPOXY
13.20
(.519)
Also available with Ø 6 mm (.236") bushing :
55100.
A-52
www.apem.com
APEM
4.70
(.185)
4.75
(.187)
LC Measurement Tool latest update to 4.22
After carefully reading the overall schematic diagram of the measuring tool today, and since anqi90 and Xinxin have already tested it, there is no problem with the circuit, so I welded a lm311 circuit...
鑫海宝贝 51mcu
Let me give you an example of a practical state machine programming idea.
Take a look at the simplest electronic watch that cost 5 yuan and was played with when I was a child. It can be operated with only 2 buttons. Let's call them button A and button B. Here is a complete ...
求知者 MCU
Different from 2.4G 4.33 780m wireless module
Technical advantages: It works in the Chinese frequency band 780MHZ or the RFID dedicated frequency band 920MHZ. The frequency band is clean, avoiding interference from civilian wireless devices such ...
hanzhixian2010 RF/Wirelessly
Power supply basics: forward circuit topology structure research
[i=s] This post was last edited by Mufan001 on 2016-12-14 15:51 [/i] [align=left][size=3][b]Power supply basics: Research on forward circuit topology structure [/b][/size][/align][align=left][size=3][...
木犯001号 Power technology
What happens if you are late for work?
Seeing comrade jxb complain about being late, I was curious, how serious are the consequences of being late? Let me talk about us first. If you are late, I hope you can consciously extend the time. Of...
向农 Talking about work
Dates I will never forget: 9●3, 12●13
my country has legislated September 3 as the Victory Day of the Chinese People's War of Resistance Against Japanese Aggression and December 13 as the National Memorial Day for the Victims of the Nanji...
dontium Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 434  2634  1131  2724  810  9  54  23  55  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号