Agilent T-1
3
/
4
(5 mm) Precision Optical
Performance AlInGaP LED Lamps
Data Sheet
SunPower Series
HLMP-ELxx HLMP-EHxx
HLMP-EJxx HLMP-EGxx
Description
These Precision Optical Perform-
ance AlInGaP LEDs provide
superior light output for
excellent readability in sunlight
and are extremely reliable.
AlInGaP LED technology
provides extremely stable light
output over long periods of time.
Precision Optical Performance
lamps utilize the aluminum
indium gallium phosphide
(AlInGaP) technology.
These LED lamps are untinted,
nondiffused, T-1
3
/
4
packages
incorporating second generation
optics producing well defined
spatial radiation patterns at
specific viewing cone angles.
These lamps are made with an
advanced optical grade epoxy,
offering superior high tempera-
ture and high moisture
resistance performance in
outdoor signal and sign
applications. The high maximum
LED junction temperature limit
of +130° C enables high
temperature operation in bright
sunlight conditions. The package
epoxy contains both uv-a and
uv-b inhibitors to reduce the
effects of long term exposure to
direct sunlight.
These lamps are available in two
package options to give the
designer flexibility with device
mounting.
Features
• Well Defined Spatial Radiation
Patterns
• Viewing Angles: 6°, 15°, 23°, 30°
• High Luminous Output
• Colors:
590 nm Amber
605 nm Orange
615 nm Reddish-Orange
626 nm Red
• High Operating Temperature:
T
J
LED
= +130°C
• Superior Resistance to Moisture
• Package Options:
With or Without Lead Stand-Offs
Benefits
• Viewing Angles Match Traffic
Management Sign Requirements
• Colors Meet Automotive and
Pedestrian Signal Specifications
• Superior Performance in Outdoor
Environments
• Suitable for Autoinsertion onto PC
Boards
Applications
• Traffic Management:
Traffic Signals
Pedestrian Signals
Work Zone Warning Lights
Variable Message Signs
• Commercial Outdoor Advertising:
Signs
Marquees
• Automotive:
Exterior and Interior Lights
Device Selection Guide
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
Color and Dominant
Wavelength
(nm), Typ.
[3]
Lamps Without
Standoffs on Leads
(Outline Drawing A)
HLMP-EL08-VY000
HLMP-EL08-VYK00*
HLMP-EL08-VXK00*
HLMP-EL08-VX400**
HLMP-EL08-VX000
HLMP-EL08-WZ000
HLMP-EL08-XZ400**
HLMP-EL08-XZ000
HLMP-EL08-XZK00*
HLMP-EL08-XY000
HLMP-EL08-XYK00*
HLMP-EL08-X1K00*
HLMP-EL08-X1000
HLMP-EJ08-WZ000
Orange 605
HLMP-EJ08-X1000
HLMP-EJ08-Y2000
HLMP-EH08-UX000
HLMP-EH08-VY000
HLMP-EH08-WZ000
HLMP-EH08-X1000
HLMP-EH08-Y2000
HLMP-EG08-VW000
HLMP-EG08-VY000
HLMP-EG08-WZ000
Red 626
HLMP-EG08-X1000
HLMP-EG08-YZ000
HLMP-EG08-Y1000
HLMP-EG08-Y2000
HLMP-EL10-X1000
HLMP-EJ10-WZ000
HLMP-EJ10-X1000
HLMP-EJ10-Y2000
HLMP-EH10-UX000
HLMP-EH10-VY000
HLMP-EH10-WZ000
HLMP-EH10-X1000
HLMP-EH10-Y2000
HLMP-EG10-VY000
HLMP-EG10-WZ000
HLMP-EG10-X1000
HLMP-EL10-WZ000
Lamps With Standoffs
on Leads
(Outline Drawing B)
HLMP-EL10-VY000
Luminous Intensity
Iv (mcd)
[1,2]
@ 20 mA
Min.
Max.
4200
12000
4200
4200
4200
4200
5500
7200
7200
7200
7200
7200
7200
7200
5500
7200
9300
3200
4200
5500
7200
9300
4200
4200
5500
7200
9300
9300
9300
12000
9300
9300
9300
16000
16000
16000
16000
12000
12000
21000
21000
16000
21000
27000
9300
12000
16000
21000
21000
7200
12000
16000
21000
16000
21000
27000
Amber 590
6°
[5]
Red-Orange 615
HLMP-EG10-Y2000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in
bold
are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
2
Device Selection Guide
(Continued)
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
Color and Dominant
Wavelength
(nm), Typ.
[3]
Lamps Without
Standoffs on Leads
(Outline Drawing A)
HLMP-EL15-PS000
HLMP-EL15-QR000
HLMP-EL15-QRK00*
HLMP-EL15-QS000
HLMP-EL15-QS400**
HLMP-EL15-QSK00*
HLMP-EL15-QT000
HLMP-EL15-QTK00*
HLMP-EL15-RU000
Amber 590
HLMP-EL15-TW000
HLMP-EL15-TWK00*
HLMP-EL15-TUK00*
HLMP-EL15-TV400**
HLMP-EL15-UX000
HLMP-EL15-VY000
HLMP-EL15-VYK00*
HLMP-EL15-VX000
HLMP-EL15-VXK00*
HLMP-EL15-VX400**
HLMP-EL15-VW000*
HLMP-EL15-VWK00*
HLMP-EJ15-PS000
HLMP-EJ15-RU000
HLMP-EJ15-SV000
HLMP-EH15-QT000
HLMP-EH15-RU000
HLMP-EH15-TW000
HLMP-EH15-UX000
HLMP-EL17-QT000
HLMP-EL17-RU000
HLMP-EL17-SV000
HLMP-EL17-TW000
Lamps With Standoffs
on Leads
(Outline Drawing B)
HLMP-EL17-PS000
Luminous Intensity
Iv (mcd)
[1,2]
@ 20 mA
Min.
Max.
880
2500
1150
1150
1150
1150
1150
1150
1150
1500
1900
2500
2500
2500
2500
3200
4200
4200
4200
4200
4200
4200
4200
880
1500
1900
1150
1500
2500
3200
1900
1900
2500
2500
2500
3200
3200
4200
5500
7200
7200
4200
5500
9300
12000
12000
9300
9300
9300
7200
7200
2500
4200
5500
3200
4200
7200
9300
15°
HLMP-EL17-UX000
HLMP-EL17-VY000
Orange 605
HLMP-EJ17-RU000
HLMP-EJ17-SV000
HLMP-EH17-QT000
HLMP-EH17-RU000
HLMP-EH17-TW000
HLMP-EH17-UX000
Red-Orange 615
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in
bold
are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
3
Device Selection Guide
(Continued)
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
Color and Dominant
Wavelength
(nm), Typ.
[3]
Lamps Without
Standoffs on Leads
(Outline Drawing A)
HLMP-EG15-PS000
HLMP-EG15-QT000
HLMP-EG15-RU000
HLMP-EG15-UX000
HLMP-EG15-TW000
HLMP-EL24-MQ000
HLMP-EL24-NR000
HLMP-EL24-PS000
HLMP-EL24-PSK00*
HLMP-EL24-PR400**
HLMP-EL24-PQK00*
HLMP-EL24-QR000
HLMP-EL24-QRK00*
HLMP-EL24-QS000
HLMP-EL24-QSK00*
23°
Amber 590
HLMP-EL24-QS400**
HLMP-EL24-QT000
HLMP-EL24-QTK00*
HLMP-EL24-RU000
HLMP-EL24-RUK00*
HLMP-EL24-STK00*
HLMP-EL24-SUK00*
HLMP-EL24-SU400**
HLMP-EL24-SV000
HLMP-EL24-SVK00*
HLMP-EL24-TW000
HLMP-EL24-TWK00*
HLMP-EL26-QT000
HLMP-EL26-RU000
HLMP-EL26-SV000
Lamps With Standoffs
on Leads
(Outline Drawing B)
HLMP-EG17-QT000
HLMP-EG17-RU000
HLMP-EG17-UX000
HLMP-EG17-TW000
HLMP-EL26-NR000
HLMP-EL26-PS000
Luminous Intensity
Iv (mcd)
[1,2]
@ 20 mA
Min.
Max.
880
2500
1150
1500
3200
2500
520
680
880
880
880
880
1150
1150
1150
1150
1150
1150
1150
1500
1500
1900
1900
1900
1900
1900
1900
2500
2500
3200
4200
9300
7200
1500
1900
2500
2500
1900
1500
1900
1900
2500
2500
2500
3200
3200
4200
4200
5500
3200
4200
4200
5500
5500
7200
7200
15°
Red 626
HLMP-EL26-TW000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in
bold
are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
4
Device Selection Guide
(Continued)
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
Color and Dominant
Wavelength
(nm), Typ.
[3]
Orange 605
Lamps Without
Standoffs on Leads
(Outline Drawing A)
HLMP-EJ24-QT000
HLMP-EJ24-RU000
HLMP-EH24-QT000
HLMP-EH24-RU000
HLMP-EH24-SV000
HLMP-EG24-PS000
Red 626
HLMP-EG24-QT000
HLMP-EG24-RU000
HLMP-EL30-MQ000
HLMP-EL30-NR000
HLMP-EL30-PQ000
HLMP-EL30-PQK00*
HLMP-EL30-PR000
HLMP-EL30-PR400**
HLMP-EL30-PRK00*
HLMP-EL30-PS000
30°
Amber 590
HLMP-EL30-PSK00*
HLMP-EL30-QRK00*
HLMP-EL30-QS000
HLMP-EL30-QS400**
HLMP-EL30-QT000
HLMP-EL30-QTK00*
HLMP-EL30-ST000
HLMP-EL30-SU000
HLMP-EL30-SU400**
HLMP-EL30-SUK00*
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in
bold
are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
Lamps With Standoffs
on Leads
(Outline Drawing B)
HLMP-EJ26-QT000
HLMP-EJ26-RU000
HLMP-EH26-PS000
HLMP-EH26-QT000
HLMP-EH26-RU000
HLMP-EH26-SV000
HLMP-EG26-PS000
HLMP-EG26-QT000
HLMP-EG26-RU000
HLMP-EL32-MQ000
HLMP-EL32-NR000
Red-Orange 615
23º
Luminous Intensity
Iv (mcd)
[1,2]
@ 20 mA
Min.
Max.
1150
3200
1500
4200
880
2500
1150
3200
1500
1900
880
1150
1500
520
680
880
880
880
880
880
880
880
1150
1150
4200
5500
2500
3200
4200
1500
1900
1500
1500
1900
1900
1900
2500
2500
1900
2500
2500
3200
3200
3200
4200
4200
4200
HLMP-EL32-PS000
HLMP-EL32-QT000
1150
1150
1150
1900
1900
1900
1900
5