EEWORLDEEWORLDEEWORLD

Part Number

Search

W.FL-LP-IN-1

Description
Tool And Machinery
CategoryThe connector    Connector bracket   
File Size178KB,6 Pages
ManufacturerHirose
Websitehttp://www.hirose-connectors.com/
Download Datasheet Parametric Compare View All

W.FL-LP-IN-1 Overview

Tool And Machinery

W.FL-LP-IN-1 Parametric

Parameter NameAttribute value
parentfamilyid1835681
MakerHirose
Objectid1829396913
Reach Compliance Codeunknown
compound_id1850091
Connector bracket typeTOOL AND MACHINERY
Manufacturer's serial numberW.FL-LP-IN-1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
Ultra Small Surface Mount Coaxial Connectors – 1.4mm Mated Height
W.FL Series
Up to 6 GHz Transmission Speed
Occupied Mounting Area
s
Features
1. Nominal mated height of 1.4 mm (Max. 1.5 mm)
2. Small mounting area
The receptacle occupies an area of 3.4mm
2
.
Mated height comparison (with U.FL Series)
3. Lightweight
(MAX1.55)
4. Accepts high frequency transmission.
To meet the frequency requirements of a wide variety of
miniature devices, the connectors offer high frequency
performance from DC to 6 GHz, with a V.S.W.R. of
1.35max.
W.FL Series
(MAX2.0)
U.FL Series
Receptacle:
Right-angle plug:
5.6 mg
18.6 mg
1.4
U.FL-LP(V)-040
W.FL-LP-040
1.9
Plug
2.85
Cable
(MAX1.55)
5. Automatic board placement
Packaged on tape-and-reel the receptacles can be
placed with vacuum nozzles of the automatic placement
equipment.
6. Plugs are terminated with ultra-fine coaxial
(fluorinated resin insulated) cable
Standard ultra-fine coaxial cable of 0.81 mm diameter
(single braid shielding) is used for the plug termination,
assuring secure and stable connections.
W. FL Plug and Receptacle
7. Simple connector mating / unmating
Use of available extraction tool assures correct
disconnection of the plug and receptacle.
Tactile click sensation confirms fully mated condition,
assuring complete electrical and mechanical connection.
1.4
8. Verification of the fully mated condition
Dia. 0.81
W.FL-R-SMT-1
Receptacle
s
Applications
Cellular phones, PHS, mobile phones, wireless
communication devices, electronic measuring instruments,
GPS, wireless LAN, Bluetooth and any application requiring
high frequency transmission using small coaxial connectors.
2009.2w
1

W.FL-LP-IN-1 Related Products

W.FL-LP-IN-1 W.FL-LP-N(01)
Description Tool And Machinery Connector Accessory,
Maker Hirose Hirose
Reach Compliance Code unknown unknown
Connector bracket type TOOL AND MACHINERY CONNECTOR ACCESSORY
AD5420 output error is large
Hello everyone, AD5420 outputs 4-20ma current, but the output error is large. Attached are two schematics and programs. Set the output to 12ma, but the output is 11.9, and then it rises little by litt...
李洪祥 ADI Reference Circuit
How to realize a passive filter with a center frequency of 70MHz and a bandwidth of 10MHz?
[size=5]I want to use dual tuning to achieve this, but I don’t know how to design it because I have too few resources. [/size] [size=5]Can any experts give me some pointers? I would appreciate it. [/s...
logitech66 RF/Wirelessly
Basic knowledge of frequency conversion technology
1. What is a frequency converter? A frequency converter is an electric energy control device that uses the on-off function of power semiconductor devices to convert industrial frequency power into ano...
ZYXWVU Power technology
Typical remote IoT sensing designs and features of Sigfox, LoRaWAN, and RIIoT
When considering wireless connectivity for Internet of Things (IoT) sensors, developers often think of Wi-Fi, Zigbee, or Bluetooth first. But the reality is that applications often require lower power...
Jacktang RF/Wirelessly
A simple way to find the cause of an exception under cortex
I posted something on another website, and I'm posting it here for your reference. Well, there is a simple method you can try. It's my personal experience, and I haven't seen it mentioned anywhere on ...
freebsder MCU
Please advise, how to use manual server+tcp/ip to debug ce5.0 application in vs2005?
The current situation is that the tools in the platform builder, such as the remote register editor, can be accessed through the manual server + TCP/IP, but in the startup program options in my VS2005...
afreebird Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2795  314  1877  1364  957  57  7  38  28  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号