ESD > 2000V per MIL-STD-883, Method 3015; > 200V using
machine model (C = 200pF, R = 0)
Available in SSOP, TSSOP, and TVSOP Packages
DESCRIPTION:
The FST163214 belong to IDT's family of Bus switches. Bus switch
devices perform the function of connecting or isolating two ports without
providing any inherent current sink or source capability. Thus they
generate little or no noise of their own while providing a low resistance path
for an external driver. These devices connect input and output ports through
an n-channel FET. When the gate-to-source junction of this FET is
adequately forward-biased the device conducts and the resistance be-
tween input and output ports is small. Without adequate bias on the gate-
to-source junction of the FET, the FET is turned off, therefore with no V
CC
applied, the device has hot insertion capability.
The low on-resistance and simplicity of the connection between input and
output ports reduces the delay in this path to close to zero.
The FST163214 provides a 12-bit TTL- compatible A port and three 12-
bit TTL compatible B ports. The S
0-2
pins provide mux select and disable
control. The A port can be connected to any one of the three B ports by
selecting appropriate S
0-2
states.
FUNCTIONAL BLOCK DIAGRAM
One of 12 Channels
1
A
1
1
B
1
1
B
3
1
B
2
Flow Control
S
0
S
1
S
2
INDUSTRIAL TEMPERATURE RANGE
1
c /-
1999
Integrated Device Technology, Inc.
OCTOBER 1999
DSC-3509/-
IDT74FST163214
12-BIT 3:1 MUX/DEMUX SWITCH
INDUSTRIAL TEMPERATURE RANGE
PIN CONFIGURATION
S0
1A
1
1B
3
2A
1
2B
3
3A
1
3B
3
GND
4A
1
4B
3
5A
1
5B
3
6A
1
6B
3
7A
1
7B
3
V
CC
8A
1
GND
8B
3
9A
1
9B
3
10A
1
10B
3
11A
1
11B
3
12A
1
12B
3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
56
55
54
53
52
51
50
49
48
47
46
45
44
SO56-1
SO56-2
SO56-3
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
SI
S2
1B
1
1B
2
2B
1
2B
2
3B
1
GND
3B
2
4B
1
4B
2
5B
1
5B
2
6B
1
6B
2
7B
1
7B
2
8B
1
GND
8B
2
9B
1
9B
2
10B
1
10B
2
11B
1
11B
2
12B
1
12B
2
ABSOLUTE MAXIMUM RATINGS
(1)
Symbol
V
TERM(2)
T
STG
I
OUT
Rating
Terminal Voltage with Respect to GND
Storage Temperature
Maximum Continuous Channel Current
Max.
–0.5 to +7
–65 to +150
128
Unit
V
°C
mA
FST LINK
NOTES:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM
RATINGS may cause permanent damage to the device. This is a
stress rating only and functional operation of the device at these or
any other conditions above those indicated in the operational sections
of this specification is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect reliability.
2. Vcc, Control, and Switch terminals.
CAPACITANCE
(1)
Symbol
Parameter
C
IN
Control Input Capacitance
C
I/O
C
I/O
Switch Input/Output
Capacitance, A Port
Switch Input/Output
Capacitance, B Port
Conditions
(2)
Switch Off
Switch Off
Typ.
7
23
13
Unit
pF
pF
pF
NOTES:
1. Capacitance is characterized but not tested.
2. T
A
= 25°C, f = 1MHz, V
IN
= 0V, V
OUT
= 0V
PIN DESCRIPTION
Pin Names
A
1
B
1
, B
2
, B
3
S
0-2
I/O
I/O
I/O
I
Description
Bus A
1
Buses B
1
, B
2
, B
3
Select Lines
FUNCTION TABLE
S
2
L
L
L
L
H
H
H
H
S
1
L
L
H
H
L
L
H
H
S
0
L
H
L
H
L
H
L
H
(1)
A
1
Z
B
1
B
2
Z
Z
B
3
B
1
B
2
Function
Disconnect
A to B
1
A to B
2
Disconnect
Disconnect
A to B
3
A to B
1
A to B
2
SSOP/ TSSOP/ TVSOP
TOP VIEW
NOTE:
1. H = HIGH Voltage level
L = LOW Voltage Level
Z = High-Impedence
2
IDT74FST163214
12-BIT 3:1 MUX/DEMUX SWITCH
INDUSTRIAL TEMPERATURE RANGE
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Conditions: T
A
= -40°C to +85°C, V
CC
= 5.0V ±10%
Symbol
V
IH
V
IL
I
IH
I
IL
I
OZH
I
OZL
V
IK
I
OFF
I
CC
Parameter
Control Input HIGH Voltage
Control Input LOW Voltage
Control Input HIGH Current
Control Input LOW Current
Current during
Bus Switch DISCONNECT
Clamp Diode Voltage
Switch Power Off Leakage
Quiescent Power Supply Current
V
CC
= Min., I
IN
= –18mA
V
CC
= 0V, V
IN
or V
O
≤
5.5V
V
CC
= Max., V
IN
= GND or V
CC
V
CC
= Max., V
O
= 0 to 5V
Test Conditions
Guaranteed Logic HIGH for Control Inputs
Guaranteed Logic LOW for Control Inputs
V
CC
= Max.
V
I
= V
CC
V
I
= GND
Min.
2
—
—
—
—
—
—
—
—
Typ.
(1)
—
—
—
—
—
—
–0.7
—
0.1
Max.
—
0.8
±1
±1
±1
±1
–1.2
±1
3
V
µA
µA
FST LINK
Unit
V
V
µA
µA
BUS SWITCH IMPEDANCE OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Conditions: T
A
= -40°C to +85°C, V
CC
= 5.0V ±10%
Symbol
R
ON
Parameter
Switch On Resistance
(2)
Test Conditions
Vcc = Min., V
IN
= 0V
I
ON
= 64mA
Vcc = Min., V
IN
= 0V
I
ON
= 30mA
Vcc = Min., V
IN
= 2.4V
I
ON
= 15mA
A(B) = 0V, B(A) = V
CC
Min.
—
—
—
100
Typ.
(1)
4
4
6
—
Max.
7
7
15
—
Unit
Ω
Ω
Ω
mA
I
OS
Short Circuit Current, A to B
(3)
NOTES:
1. Typical values are at Vcc = 5.0V, +25°C ambient.
2. The voltage drop between the indicated ports divided by the current through the switch.
3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
3
IDT74FST163214
12-BIT 3:1 MUX/DEMUX SWITCH
INDUSTRIAL TEMPERATURE RANGE
POWER SUPPLY CHARACTERISTICS
Symbol
∆I
CC
I
CCD
Parameter
Quiescent Power Supply Current
TTL Inputs HIGH
Dynamic Power Supply Current
(4, 5)
Test Conditions
(1)
V
CC
= Max.
V
IN
= 3.4V
(3)
V
CC
= Max.
Outputs Open
Select Pin Toggling
50% Duty Cycle
V
CC
= Max.
Outputs Open
3 Select Pins Toggling
(12 Switches Toggling)
fi = 10MHz
50% Duty Cycle
Min.
—
—
Typ.
(2)
0.5
30
Max.
1.5
40
Unit
mA
µ A/
MHz/
Switch
mA
V
IN
= V
CC
V
IN
= GND
I
C
Total Power Supply Current
(6)
V
IN
= V
CC
V
IN
= GND
V
IN
= 3.4
V
IN
= GND
—
3.6
4.8
—
4.4
7.1
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type. T
A
= –40°C to
+85°C
2. Typical values are at V
CC
= 5.0V, +25°C ambient.
3. Per TTL driven input (V
IN
= 3.4V). All other inputs at V
CC
or GND. Switch inputs do not contribute to
∆I
CC.
4. This parameter represents the current required to switch the internal capacitance of the control inputs at the specified frequency.
Switch inputs generate no significant power supply currents as they transition. This parameter is not directly testable, but is derived for use in Total
Power Supply Calculations.
5. C
PD
= I
CCD
/V
CC
C
PD
= Power Dissipation Capacitance
6. I
C
= I
QUIESCENT
+ I
INPUTS
+ I
DYNAMIC
I
C
= I
CC
+
∆I
CC
D
H
N
T
+ I
CCD
(f
i
N)
I
CC
= Quiescent Current
∆I
CC
= Power Supply Current for a TTL High Input (V
IN
= 3.4V)
D
H
= Duty Cycle for TTL Inputs High
N
T
= Number of TTL Inputs at D
H
I
CCD
= Dynamic Current Caused by an Input Transition Pair (HLH or LHL)
f
i
= Control Input Frequency
N = Number of Control Inputs Toggling at f
i
SWITCHING CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Conditions: T
A
= -40°C to +85°C, V
CC
= 5.0V ±10%
V
CC
= 5V ± 10%
Symbol
t
PLH
t
PHL
t
BX
t
PZH
t
PZL
t
PHZ
t
PLZ
|Q
CI
|
|Q
DCI
|
Description
(1)
Data Propagation Delay
A to B, B to A
(2)
Switch Multiplex Delay
S to A, B
Switch Turn on Delay
S to A, B
Switch Turn off Delay
S to A, B
Charge Injection During Switch DISCONNECT,
S to A or B
(3)
Charge Injection During Switch Exchange,
S to A or B
(3)
Min.
—
1.5
1.5
1.5
—
—
Typ.
—
—
—
—
1.5
0.5
Max.
0.25
6.5
6.5
7
—
—
V
CC
= 4V
Max.
0.25
7
7
7
—
—
Unit
ns
ns
ns
ns
pC
NOTES:
1. See test circuits and waveforms.
2. The bus switch contributes no Propagation Delay other than the RC Delay of the load interacting with the RC of the switch.
3. |Q
CI
| is the charge injection for a single switch DISCONNECT and applies to either single switches or multiplexers.
|Q
DCI
| is the charge injection for a multiplexer as the multiplexed port switches from one path to another. Charge injection is reduced because the
injection from the DISCONNECT of the first path is compensated by the CONNECT of the second path.
4
IDT74FST163214
12-BIT 3:1 MUX/DEMUX SWITCH
INDUSTRIAL TEMPERATURE RANGE
TEST CIRCUITS AND WAVEFORMS
TEST CIRCUITS FOR ALL OUTPUTS
V
CC
500
Ω
V
IN
Pulse
Generator
D.U.T.
50pF
R
T
PROPAGATION DELAY
7.0V
SAM E PHASE
INPUT TRANSITION
t
PLH
OUTPUT
t
PLH
t
PH L
t
PH L
3V
1.5V
0V
V
OH
1.5V
V
OL
3V
1.5V
0V
V
OUT
500
Ω
C
L
OPPOSITE PHASE
INPUT TRANSITION
SWITCH POSITION
Test
Open Drain
Disable Low
Enable Low
All Other Tests
Open
FCT LINK
SET-UP, HOLD, AND RELEASE TIMES
Switch
DATA
INPUT
t
SU
TIMING
INPUT
ASYNCHRO NOUS
CONTROL
SYNCHRONO US
CONTROL
t
REM
t
H
3V
1.5V
0V
3V
1.5V
0V
3V
1.5V
0V
3V
1.5V
0V
Closed
DEFINITIONS:
C
L
= Load capacitance: includes jig and probe capacitance.
R
T
= Termination resistance: should be equal to Z
OUT
of the Pulse
Generator.
t
SU
t
H
CHARGE INJECTION
V
CC
ENABLE AND DISABLE TIMES
ENABLE
DISABLE
3V
V
O U T(3)
Switch
Out
1 MHz
Signal
Generator
Enable/Select
Switch In
(1)
D.U.T.
(2)
CONTROL
INPUT
t
PZL
OUTPUT
NORMALLY
LOW
SW ITCH
CLOSED
t
PZH
3.5V
1.5V
0.3V
t
PHZ
0.3V
1.5V
0V
t
PLZ
1.5V
0V
3.5V
V
OL
V
OH
Switch In (MU X)
C
L
=
50pF
NOTES:
1. Select is used with multiplexers for measuring IQ
DCI
I during multiplexer
select. During all other tests Enable is used.
2. Used with multiplexers to measure IQ
DCI
I only.
3. Charge Injection =
∆V
OUT
C
L
, with Enable toggling for IQ
CI
I or Select toggling
for IQ
DCI
I.
∆V
OUT
is the change in V
OUT
and is measured with a 10MΩ
probe.
OUTPUT
NORMALLY
HIGH
SW ITCH
OPEN
0V
PULSE WIDTH
LOW -HIGH-LOW
PULS E
t
W
HIGH-LOW -HIGH
PULS E
1.5V
1.5V
NOTES:
1. Diagram shown for input Control Enable-LOW and input Control Disable-
The cc2500 is configured in variable-length data packet mode, without CRC check and address detection. The debugging results are as follows: 1 board sends a data packet, sending 32 bytes of data in ab...
I reinstalled CCS because I reinstalled the operating system. However, after the reinstallation, the project that comes with CCS cannot be imported. Please see the picture. Is there a file missing? Wh...
I need help from a master. I want to know if this module has good anti-interference performance. . . . Please explain in more detail. Thanks:victory:...
Source: PCB Technology WeChat [align=left][color=rgb(62, 62, 62)][b]Most engineers can wait for the return of the board after sending the PCB file or gerber file to the manufacturer. However, they oft...
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Describe how to meet the challenges of complexity with a modern wiring design toolset. Option codes and expressions can simulate the variables of an automotive project. A full-featured tool suite c...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
This article discusses the six design steps of LED lighting system design in detail: (1) determine the lighting requirements; (2) determine the design goals and estimate the optics; (3) the efficie...[Details]
This article introduces a high-reliability, high-power automatic water supply device made with 89C2051 single-chip microcomputer, which has phase loss detection, over-temperature detection, over-cu...[Details]
1 Introduction
Automatic Test
System The ATS (Automatic Test System) integrates all the stimulus and measurement equipment required for testing.
The computer
efficiently comp...[Details]
LonWorks fieldbus technology is widely used, for example, in intelligent buildings, industrial control, environmental protection, etc. Echelon's LonWorks system has been used in the products of tho...[Details]