MCC
Features
•
•
•
•
•
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
UFT10005
THRU
UFT10060
100
Amp
Supre Fast
Recovery
Rectifier
50 to
600
Volts
POWERMOD
A
N
Supre Fast switching for high efficiency
High Surge Capability
Low Leakage
Low Forward Voltage Drop
High Current Capability
•
•
Maximum Ratings
Operating Temperature: -55°C to +175°C
Storage Temperature: -55°C to +175°C
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
Maximum DC
Blocking
Voltage
50V
100V
200V
400V
600V
MCC
Part Number
UFT10005
UFT10010
UFT10020
UFT10040
UFT10060
Maximum
RMS Voltage
35V
70V
40V
280V
420V
C
E
B
M
Q
R
P
F
G
J
K
D
L
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
I
F(AV)
100
A
T
C
= 125°C
Current
Peak Forward Surge
I
FSM
1000A
8.3ms, half sine
Current
10005-10020
800 A
10040
10060
700 A
Maximum
Instantaneous
Forward Voltage
V
F
10005-10020
1.13V
I
FM
=
50.0A;
10040
1.25V
T
J
= 25°C
10060
1.35V
Maximum DC
Reverse Current At
I
R
50µA
T
J
= 25°C
Rated DC Blocking
6mA
T
J
=
125°C
Voltage
Maximum Reverse
Recovery Time
60ns
10005-10020
I
F
=0.5A, I
R
=1.0A,
T
rr
75ns
I
rr
=0.25A
10040
90ns
10060
Typical Junction
Capacitance
C
J
575pF
Measured at
10005-10020
300pF
1.0MHz, V
R
=10V
10040
275pF
10060
*Pulse Test: Pulse Width 300µsec, Duty Cycle
2%
H
DIMENSIONS
INCH
ES
MIN
1.995
.300
.495
.182
.990
2.390
1.490
.120
------
.240
.490
.330
.175
.035
.445
.890
MM
MIN
50.67
7.62
12.57
4.62
25.15
60.71
37.85
3.05
------
6.10
12.45
8.38
4.45
0.89
11.30
22.61
DIM
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
MAX
2.005
.325
.505
.192
1.010
2.410
1.510
.130
.400
.260
.510
.350
.195
.045
.455
.910
MAX
50.93
8.26
12.83
4.88
25.65
61.21
38.35
3.30
10.16
6.60
12.95
8.90
4.95
1.14
11.56
23.11
NOTE
∅
www.mccsemi.com
UFT10005
thrn
UFT10060
MCC
10060
120
Figure 2
Forward Derating Curve
Figure 1
Typical Forward Characteristics
200
10005-10020
100
60
40
100
20
25°C
Amps 10
6
4
2
1
.6
.4
.2
.1
0.6
0.8
1.0
Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
1.2
1.4
1.6
0
20
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
50
75
100
°C
Average Forward Rectified Current - Amperes
versus
Case
Temperature -
°C
125
150
175
Amps
40
80
10040
60
Figure 3
Junction Capacitance
1000
800
400
200
pF
T
J
=25°C
100
60
40
20
10
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
1000
20005-20020
20040
20060
Junction Capacitance - pF
versus
Reverse Voltage - Volts
www.mccsemi.com
UFT10005
thru
UFT10060
Figure 4
Typical Reverse Characteristics
5000
4000
2000
800
1000
100
60
40
20
µAmps
10
6
4
2
1
.6
.4
.2
.1
20
40
T
J
=25°C
60
80
Volts
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
100
120
140
T
J
=125°C
0
1
2
4
Amps
700
600
300
MCC
Figure
5
Peak Forward Surge Current
1000
10005-10020
10040
100
10060
6
8 10 20
Cycles
40
60 80 100
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com