Part Number

Search

UM-1-FREQ-5OT-STBY5-TOL4-AGE2-CL4-DL1

Description
Parallel - 5Th Overtone Quartz Crystal, 75MHz Min, 150MHz Max,
CategoryPassive components    Crystal/resonator   
File Size43KB,1 Pages
ManufacturerDaishinku Corp.
Websitehttp://www.kds.info/
Environmental Compliance  
Download Datasheet Parametric View All

UM-1-FREQ-5OT-STBY5-TOL4-AGE2-CL4-DL1 Overview

Parallel - 5Th Overtone Quartz Crystal, 75MHz Min, 150MHz Max,

UM-1-FREQ-5OT-STBY5-TOL4-AGE2-CL4-DL1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerDaishinku Corp.
Reach Compliance Codeunknown
Other featuresAT CUT CRYSTAL
Ageing2 PPM/YEAR
Crystal/Resonator TypePARALLEL - 5TH OVERTONE
Drive level10 µW
frequency stability0.005%
frequency tolerance20 ppm
JESD-609 codee4
load capacitance16 pF
Manufacturer's serial numberUM-1
Installation featuresTHROUGH HOLE MOUNT
Maximum operating frequency150 MHz
Minimum operating frequency75 MHz
Maximum operating temperature60 °C
Minimum operating temperature-10 °C
physical sizeL8XB3.5XH8.5 (mm)
surface mountNO
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Crystal Resonators
UM-1, UM-4, UM-5, HC-49/T, HC-49/U, HC-50/T, HC-50/U
The UM Series Resonators feature excellent frequency stability and are
suitable for pager and mobile radio applications. These highly impact-
resistant, reliable crystal resonators have been reduced in size without
trading off their electrical characteristics.
The HC Series Resonators are excellent in frequency stability and suit-
able as the reference clocks of microprocessors and other electronic
devices.
Features
Automatic mounting with tape & reel form is possible.
Series Resistance
Type Vibration
UM-4
UM-5
UM-1 HC-49/T HC-50/T
Mode
Ωmax. Ωmax. Ωmax. Ωmax. Ωmax.
Frequency
1.8∼2.0MHz
F
F
2.0∼2.4MHz
F
2.4∼3.0MHz
3.0∼3.5MHz
F
150
150
F
3.5∼4.0MHz
4.0∼7.0MHz
90
90
F
45
45
F
7.0∼10MHz
10∼15MHz
45
45
50
50
50
F
25
25
50
50
50
F
15∼20MHz
50/– 50/–
50 25/60 25/60
F/3
20∼25MHz
50/– 50/–
50 25/40 25/40
F/3
25∼30MHz
40
40
70
70
70
3
30∼75MHz
70/– 70/80 70/80
–/60 –/60
3/5
75∼100MHz
60
60
80
80
80
5
100∼125MHz
125∼150MHz
100
100
100
80
80
5
120
120
7
150∼200MHz
HC−49/U HC−50/U
Ωmax. Ωmax.
600
600
450
450
350
350
150
150
90
90
60
60
35
35
35
35
25
25
25/50 25/50
25/40 25/40
40
40
–/60 –/60
60
60
80
80
※3.75±0.2
8max.
Frequency Range
1.8∼200MHz
Vibration Mode
Thickness-shear mode (AT cut)
Fund,
3rd,
5th,
7th
Drive Level
10μW,
50μW,
100μW,
500μW
Load Capacitance
Series,
12pF, 16pF, 20pF, (fund.)
32pF
8pF, 10pF, 12pF, 16pF
(3rd, 5th, 7th)
Frequency Tolerance(at 25℃)
±5×10
-6
±10×10
-6
±15×10
-6
,
-6
-6
±20×10 ,
±30×10
Frequency Tolerance over
Temperature(Ref. to 25℃)
±5×10
-6
±10×10
-6
±20×10
-6
,
±30×10
-6
±50×10
-6
Operating Temperature Range
−10℃∼+60℃
Storage Temperature Range
−30℃∼+80℃
Aging Characteristics
UM Series:
±1×10
-6
±2×10
-6
±3×10
-6
year max.)
HC Series
-6
±5×10 /year max.)
Consult our sales representative for other specifications or special specifications.
Dimensions[mm]
5max.
L max.
6.05
−0.38
+ 0.25
5max.
L max.
20±1
※4.88±0.2
※4.88±0.2
11.5max.
11.5max.
φ1.02
L
HC-50/U 13.46
HC-50/T 11.0
L
HC-49/U 13.46
HC-49/T 11.0
3.5max.
L max.
12.5±1
UM-4
UM-5
UM-1
L
4.5
5.8
8.5
φ0.35±0.05
※Per
dimension closest to the body of the unit.
26
φ0.43
−0.02
+ 0.05
−0.07
+ 0.05
Mass flow meter principle
The first section provides an overview of the currently widely used flow meters, whether they are differential pressure type, target type, turbine type, electromagnetic or volumetric type, in principl...
totopper Industrial Control Electronics
【NXP Rapid IoT Review】
[i=s]This post was last edited by allenliu on 2019-1-21 00:45[/i] I got the board in the first batch of the review activity. The packaging is good. The box is easy to open quickly and uses magnetic su...
allenliu RF/Wirelessly
Development of a new multifunctional membrane/substrate bonding strength tester
[Abstract] A new multifunctional film/substrate bonding strength tester was developed by adopting the principle of improved scratch method and the critical load method of tangential force detection. T...
fighting Test/Measurement
Electronics question, very urgent! Need an expert to answer! Thank you!
1. The order of installation of components such as power transformers, short-circuit lines, resistors, and transistors. High-power transistors cannot be too close to (). A high power resistor B high v...
lide0001 Analog electronics
Learn more - know the power consumption of every operation of your mobile phone
[size=16px]Last week, our laboratory purchased an N6705B DC power analyzer from Agilent's agent Shenzhen Shiqiang for our voltage transient characteristic test and battery simulation test of automotiv...
袁晓牛 Integrated technical exchanges
Does CC430's WOR need timeslot synchronization?
I'm being forced to walk before I can even crawl :faint: , I'm about to use CC430F5137 for RF communication, a host communicating with several slaves, but one end of the slave must use WOR to reduce p...
sivenyu Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 765  2466  1108  1874  1606  16  50  23  38  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号