Description
CAPACITOR, ALUMINUM ELECTROLYTIC, SOLID POLYMER, POLARIZED, 2 V, 120 uF, SURFACE MOUNT, 2917
CategoryPassive components   
File Size59KB,2 Pages
ManufacturerPacelader Industrial
Download Datasheet Parametric View All

EEFSX0E151ER Overview

CAPACITOR, ALUMINUM ELECTROLYTIC, SOLID POLYMER, POLARIZED, 2 V, 120 uF, SURFACE MOUNT, 2917

EEFSX0E151ER Parametric

Parameter NameAttribute value
Maximum operating temperature105 Cel
Minimum operating temperature-40 Cel
negative deviation20 %
positive deviation20 %
Rated DC voltage urdc2 V
Processing package descriptionCHIP, ROHS COMPLIANT
Lead-freeYes
EU RoHS regulationsYes
stateACTIVE
terminal coatingTIN
Installation featuresSURFACE MOUNT
Manufacturer SeriesS
size code2917
capacitance120 uF
packaging shapeRECTANGULAR PACKAGE
Capacitor typeSOLID POLYMER
Terminal shapeWRAPAROUND
equivalent series resistance9mohm@100KHz
polarityPOLARIZED
tangent angle0.06
ripple current3A@100KHz
leakage current24uA
SP-Cap/ Conductive Polymer Aluminum Capacitors (Specialty Polymer Aluminum Capacitors)
Surface Mount Type
Series:
S
Features
Super Low-ESR (4.5 m to 9 m )
Lower ESR and Higher Capacitance at the same
case size as conventional products.
Excellent Noise-absorbent Characteristics
High Ripple Current
RoHS directive compliant
Specifications
Series & Size Code
Category Temp. Range
Rated W.V.Range
Nominal Cap.Range
Capacitance Tolerance
SL
–40 °C to +105 °C
2 V.DC to 6.3 V.DC
56 µF to 220 µF
±20 %
Reflow 240 °C : I
<
0.06 CV (µA) 2 minutes (2 V.DC to 4 V.DC)
I
<
0.04 CV (µA) 2 minutes (6.3 V.DC)
Reflow 260 °C : I
<
0.1 CV (µA) 2 minutes
tan
δ
Surge Voltage
<
0.06 (120 Hz/+20 °C)
Rated Working Voltage 1.25 (15 °C to 35 °C)
After applying rated working voltage for 1000 hours at 105 °C±2 °C, and then being stabilized at +20 °C,
capacitor shall meet the following limits.
Endurance
Capacitance change
tan
δ
DC leakage current
±10% of initial measured value
<
Initial specified value
<
Initial specified value
After storing for 500 hours at 60 °C, 90 %
2, 2.5 V.DC
+70, –20 %
<
200 % of initial specified value
<
Initial specified value
4 V.DC
+60, –20 %
6.3 V.DC
+50, –20 %
82 µF to 560 µF
SX
DC Leakage Current
Moisture resistance
Capacitance change of
initial measurd value
tan
δ
DC leakage current
Marking
Dimensions in mm(not to scale)
(Unit : mm)
-
+
H
Cap.
Polarity bar (Positive)
P
L
P
W1
W2
Lot No.
W.V. code
Series &
Size Code
SL
SX
L±0.2 W1±0.2 W2±0.1
7.3
7.3
4.3
4.3
2.4
2.4
W2
H
1.8±0.1
1.9±0.2
P±0.3
1.3
1.3
½
Externals of figure are the reference.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
00 Nov. 2012
– EEF-7 –
Is there any good input method or provider?
Everyone knows that the input method on WINCE is not very easy to use. Now I want to find a better input method. I wonder if anyone has provided one. It is also OK if there is a provider. It requires ...
opcpwm Embedded System
The role of negative pressure in LCD screens
In daily work, we occasionally encounter customer feedback: the LCD screen does not display or displays very light after it is turned on. The impact of voltage on this problem is often ignored by us. ...
罗姆液晶技术站 Integrated technical exchanges
Jiangsu Haimen City - Haimen Shouwei Electronics Co., Ltd. - Recruitment of simulation layout/design
[table=98%] [tr][td][b]We sincerely recruit talents from the society. Welcome to send your resume or call us for inquiries. Thank you! [/b] Company name: Haimen Archer Electronics Co., Ltd. Workplace:...
mixinno Recruitment
A letter from a leader to his employees: a typical leader born in the 70s and an employee born in the 80s
I want to say to the marketing department: Please be happy to accept the work at hand, don't say no. In fact, I can understand your mood and situation. In fact, the current situation you are in is the...
向农 Talking about work
What you need to know about network engineering (Part 1)
The setting of IP address and subnet mask is the basic network knowledge that every network administrator must have. Only by understanding the true meaning of IP address and subnet mask can we manage ...
wangluochuxue RF/Wirelessly
It is recommended that Jun Yixing change the courier in the future
Below is the tracking record of my development board, [b]Tracking record: [280176906103][/b] [table=98%] [tr][td][align=center]Time[/align][/td][td][align=center]City[/align][/td][td][align=center]Ope...
qin552011373 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1831  2398  240  2243  831  37  49  5  46  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号