EEWORLDEEWORLDEEWORLD

Part Number

Search

030-6067.0

Description
SPLIT BOBBIN POWER TRANSFORMER, 1.2 VA
CategoryPower/power management   
File Size487KB,12 Pages
ManufacturerPulse A Technitrol Company
Websitehttp://www.pulseeng.com
Download Datasheet Parametric View All

030-6067.0 Overview

SPLIT BOBBIN POWER TRANSFORMER, 1.2 VA

030-6067.0 Parametric

Parameter NameAttribute value
Processing package descriptionROHS COMPLIANT
each_compliYes
stateActive
Transformer typeSPLIT BOBBIN POWER TRANSFORMER
valsUL; VDE
Center Tap Feature 1NO
Center tap feature 2NO
Manufacturer SeriesEI30/12.5
Installation featuresTHROUGH HOLE MOUNTED
Number of secondary coils1
Rated operating frequency50/60 HZ
utput_current_10.1330 A
utput_voltage_19 V
cking_methodTUBE
Dimensions32.5mm X 27.5mm X 24.0mm
Rated coilDUAL 115V
Rated VA1.2 VA
heigh24 mm
length32.5 mm
width27.5 mm
LAMINATED TRANSFORMERS
Type EI30 / 5
- 0.5VA
AGENCY
APPROVALS
1.
UL 506, File E113449
2.
UL 1585, File E175197
3.
EN61558
Class 2/3
Primary
(V)
230
230
230
230
230
230
230
V
DE
Secondary
(V / mA)
6 / 83
9 / 55
12 / 42
15 / 33
18 / 28
24 / 20
2x6 / 42
2x9 / 28
2x12 / 20
2x15 / 16
2x18 / 13
2x24 / 10
6 / 83
9 / 55
12 / 42
15 / 33
18 / 28
24 / 20
2x6 / 42
2x9 / 28
2x12 / 20
2x15 / 16
2x18 / 13
2x24 / 10
6 / 83
9 / 55
12 / 42
15 / 33
18 / 28
24 / 20
2x6 / 42
2x9 / 28
2x12 / 20
2x15 /16
2x18 / 13
No-Load Schematic
Voltage
(V)
No.
10.40
15.60
20.80
25.40
29.50
38.10
2x10.60
2x15.50
2x19.70
2x24.80
2x29.80
2x39.10
10.40
15.60
20.80
25.40
29.50
38.10
2x10.60
2x15.50
2x19.70
2x24.80
2x29.80
2x39.10
10.40
15.60
20.80
25.40
29.50
38.10
2x10.60
2x15.50
2x19.70
2x24.80
2x29.80
1
1
1
1
1
1
2
2
2
2
2
2
1
1
1
1
1
1
2
2
2
2
2
2
3
3
3
3
3
3
4
4
4
4
4
Part
Number
030-7196.0
030-7197.0
030-7198.0
030-7199.0
030-7200.0
030-7201.0
030-7202.0
030-7203.0
030-7204.0
030-7205.0
030-7206.0
030-7207.0
030-7184.0
030-7185.0
030-7186.0
030-7187.0
030-7188.0
030-7189.0
030-7190.0
030-7191.0
030-7192.0
030-7193.0
030-7194.0
030-7195.0
030-5325.0
030-5328.0
030-5331.0
030-5334.0
030-5337.0
030-5343.0
030-5348.0
030-5351.0
030-5354.0
030-5357.0
030-5360.0
Agency
Approvals
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1
1
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1
1
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1/2/3*
1
Frequency 50/60Hz
Potted under vacuum
Split-bobbin
Temperature class ta 70°C/B
Short-circuit-proof (where noted:
1/2/3* under Agency Approvals)
Weight: 0.06kg
Packaging unit: 25 pieces (tube)
Mechanical
32,5
(1.28)
15
(0.60)
3,5
(0.138)
230
230
230
230
230
115
115
115
115
115
115
115
115
115
115
115
115
2x115
2x115
2x115
20
(0.80)
6
27,5
(1.08)
7
8
9
10
2x115
2x115
2x115
2x115
5
4
3
2
1
Pin Ø 0,8 mm
(Pin DIA. 0.031)
2x115
2x115
2x115
2x115
4x5
(4 x 0.20)
Schematics
No. 1
5
7
No. 2
5
6
7
9
1
9
1
10
2x115
2x24 / 10
2x39.10
4
030-5366.0
1
*NOTE:
When checking the approval status of this product with VDE, add the prefix
"BV" and the suffix "P" to the orderable Part Number (these letters will also be found
on the part label).
The prefix and suffix are not part of the orderable Part Number.
No. 3
5
4
2
1
9
7
No. 4
5
4
2
1
6
7
9
10
USA 858 674 8100
Germany 49 7032 7806 0
Singapore 65 6287 8998
Shanghai
86 21 54643211 / 2
China 86 769 85538070
Taiwan 886 3 4641811
www.pulseeng.com
5
LT2007 (9/07)
Recruiting drive engineers
Job title: Driver Engineer Job requirements: 1. Bachelor degree or above in electronics, communications, computers, automatic control and related majors; 2. More than 1 year of embedded product develo...
之城 Embedded System
Is the BEEP function of STM8S208 unusable?
I asked the ST engineer's email: ~~: Hello! I need to use the BEEP function, but after setting the register and running the program, I found that the BEEP register did not change. In the OPTION, I set...
highsea stm32/stm8
LPC11C14 IAP and CAN API issues
When I use LPC11C14 to write IAP online upgrade program, I copy the vector table of the user program to address 0 of RAM, and then remap it to address 0 of FLASH through remapping register, so as to r...
loadload NXP MCU
s3c2416 usb problem
s3c2416 If I only use USB as host, do I not need to connect other pins such as DM_UDEV DP_UDEV REXT XO_UDEV XI_UDEV?...
4027379 ARM Technology
RM48L950 Fault Coverage
The RM48 safety chip meets the IEC61508 SIL3 safety standard requirements. Its unique safety architecture enables the chip to have a high fault detection rate. So what is its fault coverage rate? Is t...
ml0943 Microcontroller MCU
Does anyone know about the ceiling control algorithm? Is there anyone who has implemented it using DSP programming?
Dear friends, does anyone know the ceiling control algorithm? Is there anyone who has implemented it using dsp programming?...
曳尾鱼 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 232  882  603  1874  2182  5  18  13  38  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号