EEWORLDEEWORLDEEWORLD

Part Number

Search

31-02.5-182BPTL

Description
Interconnection Device
CategoryThe connector    The connector   
File Size184KB,3 Pages
ManufacturerAries Electronics
Download Datasheet Parametric View All

31-02.5-182BPTL Overview

Interconnection Device

31-02.5-182BPTL Parametric

Parameter NameAttribute value
MakerAries Electronics
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Cable Length:
“L” in inches
(2” min. length)
Ex: -0002- = 2”
-02.5 = 2.5”
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
“HT”=High temperature cable insulation
“TL” = Tin/Lead Plating
“P”=Polarization stripe included
Bend Options:
“A” = Both ends bent 90?, same direction
“B” = One male end bent 90?
“C” = Both ends bent 90?, opposite direction
“D” = One female end bent 90?
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-186APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
http://www.arieselec.com • info@arieselec.com
NORTH AMERICA
Frenchtown, NJ USA
TEL:(908) 996-6841
FAX:(908) 996-3891
abc
EUROPE
TEL: +44 870 240 0249
FAX: +44 871 919 6033
europe@arieselec.com
11019
REV.H
Page
1 of 3
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
Problems in using si 2415 modem.
I use si 2415 to make a call. I find that modem dial the first telephone number slowly to be responsed . for exmple: Tel number is "4403". I send the first number "ATDT4", I can not hear the response ...
wuyusiwei Embedded System
Fujitsu FRAM experience submission MB85RC256 read and write based on MSP430F2132
[i=s]This post was last edited by zheng522 on 2014-1-10 11:15[/i]The test has already started. I will report to you below. Personally, I think that among the features of MB85RC256, the one that I valu...
zheng522 Integrated technical exchanges
How to judge the quality of a temperature sensor? Are there any industry indicators for accuracy?
How to judge the quality of a temperature sensor? Are there any industry indicators for accuracy?...
xuxuhuen Sensor
TTL vs CMOS (Super Detailed!)
TTL and CMOS1. TTL level : output high level 2.4V, output low level 0.4V . At room temperature, the general output high level is 3.5V , and the output low level is 0.2V . Minimum input high level and ...
songbo Analog electronics
Wince window size problem
I would like to ask you, can I make the dialog box automatically adapt to the size of the screen in the program I made under VC2005 to avoid the problem that the control is covered by the device borde...
kisswo Embedded System
A dead end
module fraadd(a,b); output[4:0] a,b ; wire[9:0] a , b ; It can be omitted because it is the default definition assign w=1.2 ; round up to 1 assign v=1.6 ; 2 ? assign a = 0 + 5*w ; // 5 assign b = 0 + ...
logue37 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1576  1227  966  967  1828  32  25  20  37  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号