5HSR53-D-T-FREQ

Description
Sine Output Oscillator, 10MHz Min, 30MHz Max, ROHS COMPLIANT, MINIATURE, SMD, 4 PIN
CategoryPassive components    oscillator   
File Size130KB,1 Pages
ManufacturerEuroquartz
Websitehttp://www.euroquartz.co.uk/
Environmental Compliance  
Download Datasheet Parametric View All

5HSR53-D-T-FREQ Overview

Sine Output Oscillator, 10MHz Min, 30MHz Max, ROHS COMPLIANT, MINIATURE, SMD, 4 PIN

5HSR53-D-T-FREQ Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerEuroquartz
Reach Compliance Codecompliant
Other featuresENABLE/DISABLE FUNCTION
Frequency Adjustment - MechanicalNO
frequency stability25%
Installation featuresSURFACE MOUNT
Maximum operating frequency30 MHz
Minimum operating frequency10 MHz
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Oscillator typeSINE
Output impedance10000 Ω
Output level1 V
physical size5.0mm x 3.2mm x 1.0mm
Nominal supply voltage5 V
surface mountYES
EURO
QUARTZ
5 x 3.2 x 1.0mm SMD
FEATURES
Sine Wave output in miniature SMD package
Output 10k //10pF load, level 1.0V peak to peak
Harmonics -25dBc maximum
Very low current consumption <1.0mA at 2.8V supply
HSR53 Sine Wave Oscillators
10.0MHz to 30.0MHz
OUTLINE & DIMENSIONS
DESCRIPTION
HSR53 sine wave clock oscillators provide a true sine wave out output
while being packaged in the industry-standard, 5 x 3.2mm SMD
outline package. The oscillator is capable of being produced with
close tolerances and exhibits low current consumption.
SPECIFICATION
Frequency Range:
Input Voltage:
Output Wave Form:
Frequency Stability
Commercial 0~70°C:
Industrial -40 ~+85°C:
Output Level:
Harmonics:
Phase Noise:
Current Consumption
Supply 2.8 VDC:
Supply 3.3 VDC:
Supply 5.0 VDC:
Start-up Time:
Storage Temperature:
Sub-Harmonics:
Ageing:
Enable/Disable Option:
Disable time:
10.0MHz to 30.0MHz
+2.8 VDC, +3.3 VDC or +5.0 VDC
True sine wave
±25ppm, ±50ppm or ±100ppm*
±25ppm, ±50ppm or ±100ppm*
10kW//10pF load, level 1.0V p-p
-25dBc maximum
-130 dBC/Hz at 1kHz offset
1.0mA
1.1mA
1.2mA
2.0ms typical
-55° to +125°C
None
±5ppm/year
Output is high impedance when pad 1
is taken LOW.
150ns maximum
(Add 'T' to the part number code for
this option.)
Fully compliant
SOLDER TEMPERATURE PROFILE
RoHS Status:
*
Non-standard frequency stability is available, check with sales.
PART NUMBERING
Example:
Supply Voltage
28 = 2.8 Volts
3 = 3.3 Volts
5 = 5.0 Volts
Series Designation HSR53
Stability
A = ±25ppm 0° to +70°C
B = ±50ppm 0° to +70°C
C = ±100ppm 0° to +70°C
D = ±25ppm -40° to +85°C
E = ±50ppm -40° to +85°C
F = ±100ppm -40° to +85°C
Enable/Disable Option
Blank = Not implemented
T = Option implemented
Frequency
Customer-Specific Code
(Included
if specified by
engineering department.)
3HSR53-B-T-25.000-X
EUROQUARTZ LIMITED Blacknell Lane CREWKERNE Somerset UK TA18 7HE
Tel: +44 (0)1460 230000 Fax: +44 (0)1460 230001 info@euroquartz.co.uk www.euroquartz.co.uk
wince 5.0 power display
There is no power display on my wince 5.0 development board. How can I implement it? It's so troublesome. I checked some information, but I still have no idea. It says that hardware support is needed,...
ntdx Embedded System
Designing CAN rate converter using visual programming
CAN rate conversion is a common application. For example, to connect a 250Kpbs CAN bus to a 500Kbps bus so that the data can be communicated, rate conversion is required. As shown in the following fig...
如越 Automotive Electronics
When using an oscilloscope probe to measure the AC waveform between the two ends of a component, how should the probe ground wire be connected?
When using an oscilloscope probe to measure the AC waveform between the two ends of a component, if the peak value of the AC voltage of the probe ground wire is 180V and the minimum value is -180V, th...
深圳小花 MCU
I can't find an LM5117. What can I use as a replacement? Is the LM5116 okay?
I didn't buy the LM5117. What can I use as a replacement? Is the LM5116 okay?...
明明电子 Electronics Design Contest
gprs receiving data problem
My gprs module is sim300, and I use command mode to establish a TCP connection. The received data will be directly transmitted from the serial port to the computer. Now I have a question, if an at com...
hbxt561 Embedded System
【ST NUCLEO-H743ZI Review】(2)Ethernet Test
[i=s]This post was last edited by dsjsjf on 2019-3-1 11:15[/i] [url=https://bbs.eeworld.com.cn/elecplay/content/103]The development board ST NUCLEO-H743ZI evaluated in this event is provided by STMicr...
dsjsjf stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2205  2093  886  640  795  45  43  18  13  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号