Space saving with scoop proof connector for harsh and EMI applications.
A compact solution
Diameter up to 45% smaller than D38999 size 9.
Integrated backshell: up to 50% shorter.
A high density solution
With #26 contacts (according 39029).
6 layouts (size 3, 5 and 7 with #22 & #26).
Excellent features
Designed for D38999 requirements.
IP67 sealing when mated.
Ballseal (EMI).
RoHS and Cadmium free
Available in zinc nickel (RoHS) plating, as well
as nickel and olive drab cadmium.
Not QPL listed.
8BA Series
|
Break Away
Description
• A compact solution
- The smallest connector available on the
market (shell size 3)
- Break away: quick disconnect
- Integrated backshell:
. Easy to wire and handle
. Compatible with heat shrink boot and
braid retention band
. Compliant with overmolding
• A versatile solution
- 3 shells sizes: 3, 5, 7
- Plug; In line and jam nut receptacle
- Crimp & PC tails contacts (on request)
- Removable contacts #22D & #26
- 6 keyings
• Harsh environment-resistant solution
- Scoop Proof (when sockets mounted into
receptacle only)
- Cavity to cavity sealed with interfacial seal
and grommet
- Fluid resistant
Technical features
Mechanical
• Shell:
Aluminum alloy
• Shell plating:
Aluminum:
. Zinc nickel (RoHS)
. Nickel (RoHS)
. Olive drab cadmium
• Insulator:
Thermoplastic
• Contact body:
Copper alloy
• Contacts plating:
Gold over nickel plated
• Shell endurance:
Aluminum:
500 mating/unmating cycles
• Vibration:
30 grms ambiant, 2 axes during 8 hours
• Shock:
300g, 3 ms
Electrical
• Wire size
Layouts
03-05; 05-06;
07-09
03-35; 05-35;
07-35
Wire (AWG)
24-30
22-28
Environmental
• Temperature range:
-55°C to +175°C
• Water immersion:
IP 67 on mated connector
1 meter for 30 min minimum
> IP68 with appropriate cable termination
• Salt spray:
Zinc nickel: 500 hours
Nickel: 48 hours
Olive drab cadmium: 500 hours
• Test voltage (at sea level):
Size 22D: 1000 Vrms
Size 26: 400 Vrms
• Contact resistance:
Size 22D: <14.6 mΩ
• Contact rating:
Size 22D: 5A
Size 26: <16 mΩ
Resistance to fluids
• According to MIL-DTL-38999 standard
Gasoline: JP5 (OTAN F44)
Mineral hydraulic fluid: MIL-H-5606
(OTAN H515)
Synthetic hydraulic fluid: Skydrol 500 B4
• Compatible with de-icing fluids containing
potassium acetate
Size 26: 3A
• Contact retention:
Size 22D: 45N Size 26: 30N
• Shell to shell continuity (typical value)
Shell
size
3
5
7
Aluminum
version
10 mΩ
• EMI:
Aluminum: -70dB @ 1GHz
2
8BA Series
|
Break Away
Shell types
Plug
For other configuration or PC tail version, please consult us.
In line receptacle
Jam nut receptacle
Contact layouts
03
05
35
05
06
35
07
09
35
Size 3: Marking on shell.
Rear view of receptacle for male and
female insulator.
Opposite marking between plug and
receptacle.
Sizes 5 and 7: Marking on insulator.
Rear view of male insulator for plug
and receptacle.
Opposite marking between male and
female insulator.
5#26
3#22D
6#26
3#22D
9#26
5#22D
Ordering information
Basic Series
Shell type:
1:
In line receptacle
6:
Plug
7:
Jam nut receptacle
Shell size: 03, 05, 07
Plating :
Z:
Black zinc nickel
F:
Nickel
W:
Olive drab cadmium
Contact layouts:
See above
Contact type:
P:
Pin
S:
Socket (Scoop proof only when socket contacts mounted in Type 1 & Type 7)
Orientation: N, A, B, C, D, E
(see page 5)
8BA
1
03
W
05
P
N
3
8BA Series
|
Break Away
Dimensions
Plug - Shell type 6
B
B
Shell
size
D
A
A
D
3
5
C
Shell size 3 & 5
Shell size 7
C
7
A
10.3
12.2
14.3
B Max
18.4
19.4
24
C Max ØD Max
6.1
6.1
6.1
7.3
8.9
10
In line receptacle - Shell type 1
B
Shell size
3
A
D
5
7
C
A
11
12.8
14.3
B Max
17.7
19.1
24
C Max ØD Max
6.1
6.1
6.1
7.3
9
10
Jam nut receptacle - Shell type 7
B
D
B
D
G
A
A
F
F
H
E
C
Thread
Panel
thickness
Thread
E
C
Panel
thickness
Shell size 3
Shell size
3
5
7
Thread
7/16’’28 UNEF 2A
1/2’’28 UNEF 2A
9/16’’24 UNEF 2A
A Max
10.55
12.2
13.6
Shell size 5 & 7
B Max
17.7
22.5
24
C Max
3.2
3.2
3.2
D
1.75
±0.3
1.75
±0.3
1.75
±0.3
E Max ØF Max ØG Max
6.1
6.1
6.1
7.3
8.9
10
17.5
19.5
21
ØH
Panel cut out
J
11.3
±0.1
10.6
±0.05
12.8
±0.1
12.3
±0.05
14.5
±0.1
13.8
±0.05
Note: All dimensions are in millimeters (mm)
J
4
8BA Series
|
Break Away
Orientations
Shell size 3
Master Key
Shell sizes 5 & 7
Master Key
X°
Y°
Shell
size
3
5&7
Angles
X°
Y°
Z°
N
153
145
75
A
51
130
120
B
102
110
120
C
204
155
115
D
255
90
115
E
306
90
180
Z°
Viewed from front face of plug
Connector weights
Aluminum version -
in gram ±10 %
Shell size
& layout
3-05
5-06
7-09
Plug
Without contacts
1.7
2.6
4.3
With crimp contacts
1.8
2.8
4.7
In line receptacle
Without contacts
1.3
2.9
4.7
With crimp contacts
1.4
3.1
5.1
For further information contact us at
contactmilaero@souriau.com
or visit our web site
www.souriau.com
5
All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.
[i=s]This post was last edited by dcexpert on 2015-9-9 21:12[/i] Take a look at foreign open source magazines, maybe you can broaden your mind and find some inspiration....
After everyone's brainstorming, this event decided to produce the familiar magic shake stick with romantic and magical colors~ Shake it to show your heart, shake it to show your diligence~ Say it bold...
TE Award-winning Live Broadcast: I will predict the future - the latest application of sensors in the Internet of Things. Registration is now open~Click to register nowLive Topic: Future Perception is...
[size=4]Pulse Width Modulation Mode[/size] [size=4] PWM stands for Pulse Width Modulation, which can be used to adjust the average output DC voltage. For a rectangular wave, the average output voltage...
I want a tool to convert Chinese to UCS2 code, which can input Chinese and get the code. At the same time, how is the target number generated? ? ?
It is a tool for sending Chinese text messages via mo...
Collection of multiple foreign DIY websiteshttp://www.powerlabs.org High energy DIY, electromagnetic guns, microwave weapons. http://www.altair.org/tesla.html High voltage DIY enthusiasts http://www...
There are many different ways of human-computer interaction. The more common ones are listed below:
Mouse interaction: Using a mouse to operate a computer and interact was the most common human...[Details]
In recent years, the government has increasingly supported electric vehicles, and the number of electric vehicles has increased. Observant drivers will notice that there are many more green license...[Details]
Amidst the wave of intelligent automotive transformation, advanced driver assistance is gradually emerging from cutting-edge technology into the mainstream, becoming a new frontier of industry comp...[Details]
Based on a survey of more than ten intelligent robot companies, this article sorts out and analyzes the current development status of the intelligent industry and the challenges and differences it ...[Details]
Since the beginning of this year, price wars have intensified, new models have been launched one after another, used cars with zero kilometers have become a hot topic, and the industry's internal c...[Details]
As the scale and business applications of national e-government networks continue to expand, the data and services transmitted over them are becoming increasingly sensitive and critical. To protect...[Details]
While the current industry consensus is that autonomous vehicles are robots and that their systems are managed using robotics-developed thinking, there are also cases where autonomous driving is ac...[Details]
Laird Thermal Systems has introduced the HiTemp ET series Peltier cooler modules, which can operate at high temperatures and provide on-site cooling for sensitive electronic devices.
Dig...[Details]
Normally, we determine our location and where we want to go by comparing our surroundings with observation and simple GPS tools. However, this kind of reasoning is very difficult for self-driving c...[Details]
Charging is a familiar process for new energy vehicles, and as a source of battery energy, charging piles are crucial. New energy vehicle charging can be divided into fast charging and slow chargin...[Details]
Compared to cloud databases, minicomputers are purpose-built for decentralized, rugged computing at the edge of the network. By moving applications, analytics, and processing services closer to the...[Details]
During daily operation of an R-type power transformer, the voltage used varies as the equipment being used adjusts. This raises the question: can the transformer change voltage at this point? The a...[Details]
The MCX E series is the most reliability- and safety-focused series in NXP's extensive MCX product portfolio.
With the launch of this series, NXP has further enriched its 5V-compatible MCU pr...[Details]
In the period after the switching power supply achieved the "20 kHz" revolution in the 1970s, although improvements and enhancements were made in circuit technology, the development level of the se...[Details]
There are more and more electric vehicles. Recently, I have heard some news about electric vehicles performing poorly in winter. I would like to briefly introduce whether heat pump technology is mo...[Details]