EEWORLDEEWORLDEEWORLD

Part Number

Search

PA06W-90-1MM1

Description
Mains Power Connector, 6A, 115/250VAC, Male, Socket
CategoryThe connector    The connector   
File Size269KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Download Datasheet Parametric View All

PA06W-90-1MM1 Overview

Mains Power Connector, 6A, 115/250VAC, Male, Socket

PA06W-90-1MM1 Parametric

Parameter NameAttribute value
MakerPower Dynamics, Inc.
Objectid2099204005
Reach Compliance Codecompliant
compound_id55828889
Other featuresSTANDARDS: IEC 60320; UL; CSA; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings6A, 115/250VAC
Manufacturer's serial numberPA
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
PA Series
RIGHT ANGLE, FLANGE MOUNT FILTER WITH IEC 60320 AC INLET SOCKET.
MECHANICAL DIMENSIONS
(Unit: mm)
40.0
G
2X
3.3
32.8
G
22.5
30.3
50.1
36.3
39.8
24.4
20.2
13.9
FEATURES
General purpose, Low cost filter with IEC connector providing
effective equipment protection of line-to-ground noise up to
15 Amp, 250VAC. The compact design filter with low
leakage current is well suited for applications that require
strict emission standards. These filters are also available for
Medical application and offer extremely low Leakage
current to comply with various industry standards.
Ground Choke can be added to enhance the grounding
ability of the circuit. Bleeder resistor can be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
28.4
40.0
30.5
41.3
4X R4.5
21.8
2X
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 6A, 10A, 15A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
4
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
Op amp circuit knowledge: voltage feedback, common indicators, good and bad judgment...
What is an operational amplifier? Many textbooks and reference guides define an operational amplifier (op amp) as a special-purpose integrated circuit (IC) that can perform a variety of functions or o...
Jacktang Energy Infrastructure?
There is a problem with the industrial computer, please give me some advice!
My company has a device, the computer is used as the host computer to control PLC, PLC controls temperature control and mechanical mechanism, PLC and computer communicate via serial port, the computer...
eeleader Industrial Control Electronics
SQL CE database operation problem
if(FAILED(CoInitializeEx(NULL, COINIT_MULTITHREADED))) return FALSE; IID__Connection, (LPVOID*&m_pConn); hr = m_pConn->put_Provider(L"\\DiskOnChip\\pda\\myce.sdf"); hr = m_pConn->Open(L"Provider=micro...
zl0801 Embedded System
What does this warning mean?
"Example_2833xScia_FFDLB.c", line 172: warning: variable "Error" was declared but never referenced, how to fix it...
flyfish1986 DSP and ARM Processors
Online help on how to initialize TI's ads1252! ????
I have been working on this for a long time, but I still can't get it right. I hope someone who has done this before can give me some suggestions and advice. There is too little information about ADS1...
海盗郭兆广 TI Technology Forum
How do I flash the firmware on my JLink?
[i=s]This post was last edited by Bingqi23 on 2016-7-26 15:01[/i] I was going to try to connect the UFUN learning board with JLink today, but I found that my JLink was identified as a pirated version....
Bingqi23 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1804  1494  2570  657  2079  37  31  52  14  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号