MIL–PRF (CWR Style) Established Reliability – T409 Series CWR09 Style MIL–PRF–55365/4
Table 1 – Ratings & Part Number Reference
Rated
Voltage
V
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25
25
V
Rated
Cap
µF
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
0.33
0.68
1
1.5
2.2
4.7
6.8
µF
Case Code/
Case Size
KEMET/EIA
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
H/2915
A/1005
B/1505
C/2005
D/1510
E/2010
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T409A225(1)004(2)(3)(4)
T409B475(1)004(2)(3)(4)
T409C685(1)004(2)(3)(4)
T409D106(1)004(2)(3)(4)
T409E156(1)004(2)(3)(4)
T409F336(1)004(2)(3)(4)
T409G686(1)004(2)(3)(4)
T409H107(1)004(2)(3)(4)
T409A155(1)006(2)(3)(4)
T409B335(1)006(2)(3)(4)
T409C475(1)006(2)(3)(4)
T409D685(1)006(2)(3)(4)
T409E106(1)006(2)(3)(4)
T409F226(1)006(2)(3)(4)
T409G476(1)006(2)(3)(4)
T409H686(1)006(2)(3)(4)
T409A105(1)010(2)(3)(4)
T409B225(1)010(2)(3)(4)
T409C335(1)010(2)(3)(4)
T409D475(1)010(2)(3)(4)
T409E685(1)010(2)(3)(4)
T409F156(1)010(2)(3)(4)
T409G336(1)010(2)(3)(4)
T409H476(1)010(2)(3)(4)
T409A684(1)015(2)(3)(4)
T409B155(1)015(2)(3)(4)
T409C225(1)015(2)(3)(4)
T409D335(1)015(2)(3)(4)
T409E475(1)015(2)(3)(4)
T409F106(1)015(2)(3)(4)
T409G226(1)015(2)(3)(4)
T409H336(1)015(2)(3)(4)
T409A474(1)020(2)(3)(4)
T409B684(1)020(2)(3)(4)
T409B105(1)020(2)(3)(4)
T409C155(1)020(2)(3)(4)
T409D225(1)020(2)(3)(4)
T409E335(1)020(2)(3)(4)
T409F685(1)020(2)(3)(4)
T409G156(1)020(2)(3)(4)
T409H226(1)020(2)(3)(4)
T409A334(1)025(2)(3)(4)
T409B684(1)025(2)(3)(4)
T409C105(1)025(2)(3)(4)
T409D155(1)025(2)(3)(4)
T409E225(1)025(2)(3)(4)
T409F475(1)025(2)(3)(4)
T409G685(1)025(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/4
Part Number
(See below for
part options)
CWR09C(3)225(1)(2)(5)
CWR09C(3)475(1)(2)(5)
CWR09C(3)685(1)(2)(5)
CWR09C(3)106(1)(2)(5)
CWR09C(3)156(1)(2)(5)
CWR09C(3)336(1)(2)(5)
CWR09C(3)686(1)(2)(5)
CWR09C(3)107(1)(2)(5)
CWR09D(3)155(1)(2)(5)
CWR09D(3)335(1)(2)(5)
CWR09D(3)475(1)(2)(5)
CWR09D(3)685(1)(2)(5)
CWR09D(3)106(1)(2)(5)
CWR09D(3)226(1)(2)(5)
CWR09D(3)476(1)(2)(5)
CWR09D(3)686(1)(2)(5)
CWR09F(3)105(1)(2)(5)
CWR09F(3)225(1)(2)(5)
CWR09F(3)335(1)(2)(5)
CWR09F(3)475(1)(2)(5)
CWR09F(3)685(1)(2)(5)
CWR09F(3)156(1)(2)(5)
CWR09F(3)336(1)(2)(5)
CWR09F(3)476(1)(2)(5)
CWR09H(3)684(1)(2)(5)
CWR09H(3)155(1)(2)(5)
CWR09H(3)225(1)(2)(5)
CWR09H(3)335(1)(2)(5)
CWR09H(3)475(1)(2)(5)
CWR09H(3)106(1)(2)(5)
CWR09H(3)226(1)(2)(5)
CWR09H(3)336(1)(2)(5)
CWR09J(3)474(1)(2)(5)
CWR09J(3)684(1)(2)(5)
CWR09J(3)105(1)(2)(5)
CWR09J(3)155(1)(2)(5)
CWR09J(3)225(1)(2)(5)
CWR09J(3)335(1)(2)(5)
CWR09J(3)685(1)(2)(5)
CWR09J(3)156(1)(2)(5)
CWR09J(3)226(1)(2)(5)
CWR09K(3)334(1)(2)(5)
CWR09K(3)684(1)(2)(5)
CWR09K(3)105(1)(2)(5)
CWR09K(3)155(1)(2)(5)
CWR09K(3)225(1)(2)(5)
CWR09K(3)475(1)(2)(5)
CWR09K(3)685(1)(2)(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Maximum/5
Minutes
1
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
5.0
1.0
1.0
1.0
1.0
1.0
2.0
4.0
5.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
4.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
µA @ +20ºC
Maximum/5
Minutes
DF
% @ +20ºC
120 Hz
Maximum
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
% @ +20ºC
120 Hz
Maximum
ESR
Ω @ +20ºC
100 kHz
Maximum
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
5.5
4.5
3.5
2.2
1.1
0.9
10.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
10.0
12.0
6.0
5.0
4.0
2.4
1.1
0.9
15.0
7.5
6.5
6.5
3.5
2.5
1.2
Ω @ +20ºC
100 kHz
Maximum
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part
Number
MIL-PRF-55365/4
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates termination finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, or C = -55°C +85°C before Weibull. Designates surge current
option. Refer to Ordering Information for additional detail.
The following error message: Error[e72]: Segment FIQ_STACK must be defined in a segment definition option (-Z, -b or -P) I defined MODULE like this ?CSTARTUP RSEG IRQ_STACK:DATA(2) RSEG FIQ_STACK:DATA...
The K510 board just arrived this morning . In order to help engineers get started with development, Canaan plans to record a training video. The initial idea is to include:
-How to master board develo...
Now we directly call the calibration program that comes with the system. The method is as follows: First, add the function pointer definition in the header file: typedef BOOL (WINAPI *_TouchCalibrate)...
Weighing range: 0-500g, precision 1g, requires the use of LCD1602 display, battery power supply, mainly to achieve low power consumption design of the whole system, functions: weight display function,...
In
circuit design,
current
measurement
is widely used, and the main fields are divided into three categories: in measurement,
the electric meter
is used to measure the curre...[Details]
1. Overview
Will passive devices
produce nonlinear intermodulation distortion? The answer is yes! Although there is no systematic theoretical analysis, it has been found in engineerin...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guang...[Details]
This paper establishes a fuel cell engine test platform based on the NI integrated hardware and software environment. This platform can realize the test and control of fuel cell engines and their a...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
I. Introduction
Since RS232 has a short communication distance (only 15 meters according to EAT/TAI-232 standard), and can only perform point-to-point communication, it cannot directly f...[Details]
Digital array radar (DAR) uses digital beam forming (DBF) in both receiving and transmitting modes to achieve flexible distribution and reception of RF signal power in the airspace, obtain excellent t...[Details]
TC9012F is a universal CMOS large-scale integrated circuit for infrared remote control signal transmission, suitable for remote control of TV, VTR, laser player and other equipment. In the market, ...[Details]
This article will introduce a design method for a distributed control system used in a tracking car, which can perform distributed control of motor modules, sensor modules, and lighting control mod...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]
Introduction
In industrial control, speed measurement is often required. Generally, a contact tachometer is used. This tachometer must be placed against the center of the shaft to measure. It...[Details]
Currently, each country is developing its own USB interface
charging specifications
, which leads to a major problem that a USB interface
charging
device manufactured in one country...[Details]
1. Proposal of
reconfigurable
measurement and control system
The measurement and control system generally refers to a system based on
computers
to realize data acquisition a...[Details]
A stepper motor is an electromagnetic mechanical device that converts an electrical pulse signal into an angular displacement or a linear displacement. The stability and reliability of a stepper mo...[Details]
Nowadays, more and more people have digital cameras. The convenience and speed of digital cameras have gradually replaced film cameras and become the main tool for people's daily photography. The n...[Details]