MIL–PRF (CWR Style) Established Reliability – T419 Series CWR19 Style MIL–PRF–55365/11
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
VDC
Rated
Cap
µF
3.3
4.7
6.8
10
15
22
22
33
33
47
68
100
150
220
330
3.3
4.7
6.8
10
15
15
15
22
22
33
47
68
68
100
150
220
330
2.2
3.3
4.7
4.7
6.8
6.8
6.8
10
10
10
10
15
15
22
33
47
47
µF
Case Code/
Case Size
KEMET/EIA
A/1005
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
D/1510
E/2010
E/2010
E/2010
F/2214
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
G/2711
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
C/2005
B/1505
C/2005
D/1510
B/1505
C/2005
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T419A335(1)004(2)(3)(4)
T419A475(1)004(2)(3)(4)
T419A685(1)004(2)(3)(4)
T419B106(1)004(2)(3)(4)
T419B156(1)004(2)(3)(4)
T419B226(1)004(2)(3)(4)
T419D226(1)004(2)(3)(4)
T419D336(1)004(2)(3)(4)
T419E336(1)004(2)(3)(4)
T419E476(1)004(2)(3)(4)
T419E686(1)004(2)(3)(4)
T419F107(1)004(2)(3)(4)
T419G157(1)004(2)(3)(4)
T419H227(1)004(2)(3)(4)
T419H337(1)004(2)(3)(4)
T419A335(1)006(2)(3)(4)
T419A475(1)006(2)(3)(4)
T419B685(1)006(2)(3)(4)
T419B106(1)006(2)(3)(4)
T419B156(1)006(2)(3)(4)
T419D156(1)006(2)(3)(4)
T419E156(1)006(2)(3)(4)
T419D226(1)006(2)(3)(4)
T419E226(1)006(2)(3)(4)
T419E336(1)006(2)(3)(4)
T419F476(1)006(2)(3)(4)
T419F686(1)006(2)(3)(4)
T419G686(1)006(2)(3)(4)
T419G107(1)006(2)(3)(4)
T419G157(1)006(2)(3)(4)
T419H227(1)006(2)(3)(4)
T419H337(1)006(2)(3)(4)
T419A225(1)010(2)(3)(4)
T419A335(1)010(2)(3)(4)
T419B475(1)010(2)(3)(4)
T419C475(1)010(2)(3)(4)
T419B685(1)010(2)(3)(4)
T419C685(1)010(2)(3)(4)
T419D685(1)010(2)(3)(4)
T419B106(1)010(2)(3)(4)
T419C106(1)010(2)(3)(4)
T419D106(1)010(2)(3)(4)
T419E106(1)010(2)(3)(4)
T419D156(1)010(2)(3)(4)
T419E156(1)010(2)(3)(4)
T419E226(1)010(2)(3)(4)
T419F336(1)010(2)(3)(4)
T419F476(1)010(2)(3)(4)
T419G476(1)010(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/11
Part Number
(See below for
part options)
CWR19C(3)335(1)(2)A(5)
CWR19C(3)475(1)(2)A(5)
CWR19C(3)685(1)(2)A(5)
CWR19C(3)106(1)(2)B(5)
CWR19C(3)156(1)(2)B(5)
CWR19C(3)226(1)(2)B(5)
CWR19C(3)226(1)(2)D(5)
CWR19C(3)336(1)(2)D(5)
CWR19C(3)336(1)(2)E(5)
CWR19C(3)476(1)(2)E(5)
CWR19C(3)686(1)(2)E(5)
CWR19C(3)107(1)(2)F(5)
CWR19C(3)157(1)(2)G(5)
CWR19C(3)227(1)(2)H(5)
CWR19C(3)337(1)(2)H(5)
CWR19D(3)335(1)(2)A(5)
CWR19D(3)475(1)(2)A(5)
CWR19D(3)685(1)(2)B(5)
CWR19D(3)106(1)(2)B(5)
CWR19D(3)156(1)(2)B(5)
CWR19D(3)156(1)(2)D(5)
CWR19D(3)156(1)(2)E(5)
CWR19D(3)226(1)(2)D(5)
CWR19D(3)226(1)(2)E(5)
CWR19D(3)336(1)(2)E(5)
CWR19D(3)476(1)(2)F(5)
CWR19D(3)686(1)(2)F(5)
CWR19D(3)686(1)(2)G(5)
CWR19D(3)107(1)(2)G(5)
CWR19D(3)157(1)(2)G(5)
CWR19D(3)227(1)(2)H(5)
CWR19D(3)337(1)(2)H(5)
CWR19F(3)225(1)(2)A(5)
CWR19F(3)335(1)(2)A(5)
CWR19F(3)475(1)(2)B(5)
CWR19F(3)475(1)(2)C(5)
CWR19F(3)685(1)(2)B(5)
CWR19F(3)685(1)(2)C(5)
CWR19F(3)685(1)(2)D(5)
CWR19F(3)106(1)(2)B(5)
CWR19F(3)106(1)(2)C(5)
CWR19F(3)106(1)(2)D(5)
CWR19F(3)106(1)(2)E(5)
CWR19F(3)156(1)(2)D(5)
CWR19F(3)156(1)(2)E(5)
CWR19F(3)226(1)(2)E(5)
CWR19F(3)336(1)(2)F(5)
CWR19F(3)476(1)(2)F(5)
CWR19F(3)476(1)(2)G(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Max/5 Min
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
3.0
4.0
6.0
8.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.8
4.0
4.0
6.0
10.0
10.0
20.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
3.0
3.0
4.0
4.0
µA @ +20ºC
Max/5 Min
DF
% @ 20ºC
120 Hz Max
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
6.0
8.0
6.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
% @ 20ºC
120 Hz Max
ESR
Ω @ +20ºC
100 kHz Max
12.0
12.0
12.0
8.0
8.0
8.0
4.0
4.0
3.0
3.0
3.0
2.0
1.0
1.0
0.9
12.0
12.0
8.0
8.0
8.0
5.0
3.0
5.0
3.5
3.5
3.5
1.5
1.0
1.1
1.1
0.9
0.9
12.0
12.0
8.0
5.5
8.0
5.5
5.0
8.0
5.5
4.0
3.5
5.0
3.0
2.0
1.5
1.5
1.0
Ω @ +20ºC
100 kHz Max
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated Cap
Case Code/
Case Size
KEMET Part Number
MIL–PRF–55365/11
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, C = -55°C +85°C before Weibull or Z = None. Designates Surge
current option.
Refer to Ordering Information for additional detail.
Recently, when many mobile power brands are promoting their products, many of them use mAh as the unit capacity as the standard for the quality of a power product. However, if you really understand th...
I often can't find the ID when running a NIOS project. I have been hanging out in the official forum for a long time. Some people say that I can just ignore it. But in fact, it won't work after 9.0 if...
When parsing the file path in the driver, fileobject->filename is a multi-data stream: Docf_ SummaryInformation:$DATA. What is the use of this? This information is not used in the path. What is the di...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
Dual-mode inverters can operate both in conjunction with the grid and independently. These inverters can inject excess energy from renewable energy and storage devices into the grid, and withdraw p...[Details]
In recent years, with the increasing demand for manufacturing and automated production management, industrial barcode scanners have gradually become an indispensable part of the industrial manufact...[Details]
A line scan lens is an industrial lens used with line scan cameras. Its imaging principle is to capture the image of the workpiece using a linear sensor and then perform digital signal processing t...[Details]
The mass production process of the new generation of cockpit platform has started, and the smart cockpit market has entered a new bonus cycle of technology iteration and platform upgrade.
...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
In mobile technology, sensors are the primary input for measured signals and form a component of a sensor system. They include sensitive and transducer elements connected to carriers and circuits. ...[Details]
summary
There are multiple approaches to making industrial systems more intelligent, including applying artificial intelligence (AI) technology at the edge and in the cloud to sensor...[Details]
Recently, South Korean robotics giant WIRobotics launched its first general-purpose humanoid robot, ALLEX, at the Robotics Innovation Center (RIH) at the Korea University of Science and Technology....[Details]
For autonomous vehicles to safely navigate the road, they must identify far more complex objects than just traffic lights, pedestrians, and other familiar objects. Among these obstacles is a crucia...[Details]
introduction
According to the China Fire Statistics Yearbook, electrical fires accounted for more than 30% of fire accidents in the past decade, and the trend is increasing year by year. They ...[Details]
UPS stands for Uninterruptible Power Supply, which includes energy storage devices. It is mainly used to provide uninterruptible power supply for devices that require high power stability.
...[Details]
Linear motor modules have become the "sweet spot" in various fields due to their advantages such as long stroke, fast speed, high precision, smooth operation and long life. Different models of line...[Details]
According to foreign media reports, Ford Motor has applied to the U.S. Patent and Social Security Office (USPTO) for a patent for a door anti-collision system that may be used in future Ford vehicl...[Details]
To improve the lateral active safety of intelligent connected vehicles, the identification and definition of unexpected functional safety scenarios for the EPS (Electronic Steering System) ...[Details]