50 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK
CategoryThe connector   
File Size239KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

B383913L5 Overview

50 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK

B383913L5 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Other features94V-0
Fastening methodSCREW
Manufacturer's serial numberB38
Number of layers1
Rows1
Number of channels13
Rated current50 A
Rated voltage600 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
INDEX
Series A38 / B38
Single Row Terminal Blocks
SPECIFICATIONS
Rating:
A38: 30A, 600V
B38: 50A, 600V
Center Spacing:
.437” (11.10 mm)
Wire Size:
#10-22 AWG CU
Screw Size:
#8-32 Zinc Plated Steel
Torque Rating:
A38: 9 in-lb; B38: 15 in-lb
Distance Between Barriers:
.378” (9.60mm)
Operating Temperature:
221°F (105°C)
Molded Material:
Black, UL Rated 94VO Thermoplastic
Breakdown Voltage:
5000V rms
Recommended PCB Hole Diameter (A38):
.076” (1.93mm)
Approvals:
UL E62622; CSA LR15364; CE Certified
TABLE A
MOUNTING
ENDS ONLY
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
B
Mount Ctrs.
1.31
1.75
2.19
2.62
3.06
3.50
3.93
4.37
4.81
5.24
5.68
6.12
6.56
6.99
7.43
“A”
Dim. Length
1.67
2.10
2.54
2.98
3.41
3.85
4.29
4.72
5.16
5.60
6.04
6.47
6.91
7.35
7.78
BARRIER
ENDS ONLY
“A”
Dim. Length
0.93
1.37
1.81
4.05
2.68
3.12
3.56
3.99
4.43
4.87
5.30
5.74
6.18
6.61
7.05
A382208
B381404
Series A38
"A" DIM.
"B" DIM.
HOLE SIZE
.20
(5.0)
11.10
(.437)
.80
(20.4)
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
.28
(7.0)
Series B38
"A" DIM.
.437
(11.10)
.65
(16.4)
.21
(5.2)
.25
(6.4)
Cooper Bussmann
l
7300 W. Wilson Ave
l
Chicago, IL 60656-4708
l
Fax: 708-867-2211
l
Phone: 708-867-4600
Website: http://www.busscc.com
19
Friendly Arm MINI2440 User Manual
[b]Contents[/b] Chapter 1 Introduction to MINI2440 Development Board...................................................................................- 11 - 1.1 Introduction to MINI2440 Development B...
clark Embedded System
LPC2368 xmodem bootloader program problem
I have made a bootloader program for LPC2368 xmodem. The design idea is to store two independent projects in the LPC2368's on-chip FLASH. After powering on, the first program is run, which is stored i...
eeleader MCU
Environmental online monitoring products based on Hercules TMS570
[table=500] [/table]...
dzc2001 Microcontroller MCU
Please advise on the short-circuit protection of DA output (urgent)
I have designed a signal source with an amplitude of +-5V using FPGA and DAC8734. The short-circuit current of DAC8734 is 10mA, but I cannot find a thermistor with such a small current. Is there any s...
guolei1019 Analogue and Mixed Signal
ST7565 Serial Driver
/* In the serial drive mode, the only thing to note is that although the WR and RD pins are not used, they must be grounded, otherwise the display will not be normal; /**************************Prepro...
eeleader NXP MCU
How to re-program the program with STVisualProgrammer after STM8 is protected
After STM8 is protected, how can I use ST Visual Programmer to re-program the program? Please give me some advice, I will be very grateful!...
chifeng0823 stm32/stm8

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 577  1245  2620  1398  137  12  26  53  29  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号