EMI Suppression Capacitors
X1 / 440 Vac
X1 capacitors
Rated ac voltage 440 V, 50/60 Hz
Construction
I
I
I
I
B 81 141
Dielectric: polyester (MKT)
Internal series connection
Plastic case (UL 94 V-0)
Epoxy resin sealing, flame-retardant
Features
I
Self-healing properties
Terminals
I
Parallel wire leads, tinned
I
Two standard lead lengths available:
Lead spacing
±
0,4
Lead diameter Lead length
l
1
∅
d
(mm)
(mm)
0,8
1,0
6
−
1
6
−
1
26
±
2
26
±
2
6 mm and 26 mm
Other lead lengths available upon request.
Marking
Manufacturer’s logo, lot number,
date code,
rated capacitance (coded),
capacitance tolerance (code letter),
rated ac voltage, type number,
interference suppression sub-class (X1),
style (MKT), self-healing (SH), climatic category,
awarded marks of conformity.
Delivery mode
≤
27,5 mm
37,5 mm
AAAAA C1154
XX-µ15 M 440V~
B81141 X1 MKT/SH
40/085/21/C
250V~ 250V~
IEC 384
14 (2)
KMK0568-H
Bulk (untaped)
Taped (Ammo pack or reel)
For notes on taping,
refer to chapter “Taping and packing”, page 274.
Marks of conformity
Marks of
conformity
Standards
EN 132 400, IEC 384-14, 2nd edition
UL 1414 (250 V)
CSA C22.2 No. 0; 8 (250 V)
Certificate
9547071-01
E 97863
LR 59709
228
12/00
B 81 141
440 Vac
Ordering codes and packing units
Lead
spacing
±
0,4
mm
15
C
R
Maximum
dimensions
b
×
h
×
l
(mm)
5,0
×
10,5
×
18,0
7,0
×
12,5
×
18,0
8,5
×
14,5
×
18,0
9,0
×
17,5
×
18,0
Ordering code
1)
X1
Packing units (pcs)
Ammo Reel
Untaped
pack
Lead length
6 mm
26 mm
1300
900
700
700
500
400
350
300
–
–
–
1000
1000
500
500
510
540
510
280
260
200
100
–
1000
800
500
500
450
350
300
200
150
100
10 nF
22 nF
33 nF
47 nF
B81141-C1103-M
***
1170
B81141-C1223-M
***
830
B81141-C1333-M
***
680
B81141-C1473-M
***
640
480
390
370
22,5
68 nF
8,5
×
16,5
×
26,5 B81141-C1683-M
***
0,10
µ
F 10,5
×
16,5
×
26,5 B81141-C1104-M
***
0,15
µ
F 11,0
×
20,5
×
26,5 B81141-C1154-M
***
0,22
µ
F 12,5
×
21,5
×
31,5 B81141-C1224-M
***
–
0,33
µ
F 14,0
×
24,5
×
31,5 B81141-C1334-M
***
–
0,47
µ
F 18,0
×
27,5
×
31,5 B81141-C1474-M
***
–
0,68
µ
F 16,0
×
28,5
×
41,5 B81141-C1684-M
***
–
27,5
37,5
Capacitance tolerance:
±
20 % = M (closer tolerances upon request)
ˆ
Technical data
Climatic category
in accordance with IEC 60068-1
Lower category temperature
T
min
Upper category temperature
T
max
40/085/21
−
40
°
C
+
85
°
C
Passive flammability category
in accordance with IEC 40 (CO) 752 C
Damp heat test
Limit values after damp
heat test
21 days/40
°
C/93 % relative humidity
Capacitance change |
∆
C/C|
Dissipation factor change
∆
tan
δ
Insulation resistance
R
is
or time constant
τ
=
C
R
⋅
R
is
440 V (50/60 Hz)
1000 V
2500 V, 2 s
≤
5%
≤
5
⋅
10
−3
(at 1 kHz)
≥
50 % of minimum
as-delivered values
Permissible
continuous ac voltage
Permissible continuous dc voltage
DC test voltage
1) Replace the *** by the code number for the required lead length or packing.
000 = lead length 6 mm (untaped)
026 = lead length 26 mm (untaped)
289 = taped, Ammo pack
189 = taped, reel
229
12/00
X1
B 81 141
440 Vac
Technical data
Dissipation factor tan
δ
(in 10
−3
)
at 20
°
C
(upper limit values)
C
R
≤
0,1
µ
F
1 kHz 8
10 kHz 15
100 kHz 30
0,1
µ
F
<
C
R
≤
1
µ
F
C
R
>
1
µ
F
8
15
–
10
–
–
at
Insulation resistance
R
is
or time constant
τ
=
C
R
⋅
R
is
at 20
°
C, rel. humidity
≤
65 %
(minimum as-delivered values)
Impedance
Z
versus frequency
f
(typical values)
C
R
≤
0,33
µ
F
30 000 M
Ω
C
R
>
0,33
µ
F
10 000 s
Pulse handling capability
Maximum permissible voltage change per unit of time for non-sinusoidal voltages (pulse, sawtooth).
V
R
Max. rate of voltage rise
V
pp
/
τ
in V/
µ
s (for
V
pp
=
V
R
)
ˆ
Lead spacing
15 mm
440 Vac
80
22,5 mm
50
27,5 mm
30
37,5 mm
15
ˆ
ˆ
For
V
pp
<
V
R
, the permissible voltage rise rate
V
pp
/
τ
may be multiplied by the factor
V
R
/V
pp
.
Also refer to the calculation example
in chapter “General technical information”, page 302.
V
R
Pulse characteristic
k
0
in V
2
/
µ
s (for
V
pp
≤
V
R
)
ˆ
Lead spacing
15 mm
440 Vac
100 000
22,5 mm
50 000
27,5 mm
30 000
37,5 mm
18 000
230
12/00
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgele-
genen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte
darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsge-
sellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this bro-
chure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be con-
sidered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1