EEWORLDEEWORLDEEWORLD

Part Number

Search

56.34.9.012.0306

Description
Electromechanical Relay, 4PDT, 13.2VDC (Coil), 1.3W@12VDCmW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.34.9.012.0306 Overview

Electromechanical Relay, 4PDT, 13.2VDC (Coil), 1.3W@12VDCmW (Coil), Random, AC/DC Output

56.34.9.012.0306 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width27.7 mm
body height37.1 mm
Body length or diameter40.8 mm
Coil operating voltage (DC)10.2 V
Coil power1300 mW
Coil resistance123 Ω
Maximum coil voltage (DC)13.2 V
Nominal coil voltage12 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Nickel
Input switching control typeRandom
Number of terminals14
operating hours10 ms
physical size40.8mm x 27.7mm x 37.1mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay function4PDT
release time4 ms
Terminal length0.007 inch
Termination typeQUICK CONNECT
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
[Repost] 16 basic knowledge points of operational amplifiers
[align=left][color=rgb(25, 25, 25)][font="]1. Generally, there is a balancing resistor in the inverting/non-inverting amplifier circuit. What is the function of this balancing resistor?[/font][/color]...
皇华Ameya360 Power technology
CC2640R2F BLE5.0 Bluetooth protocol stack generates off-chip command files
[i=s]This post was last edited by Jacktang on 2020-4-15 07:39[/i]How to convert the standard SDK connector command file into an OAD-compliant connector command file. The following takes cc26xx_app_and...
Jacktang Wireless Connectivity
Is there any brother who is familiar with WINCE development in Shenzhen and can do part-time work?
There is a small project that will take about two months. If you are interested, please leave your contact information to discuss the content and remuneration....
211wujianhua Embedded System
Where did you get the startup code?
I just learned ARM and read a lot of articles about startup code on the Internet. They are almost the same. So I have a little question Did the engineers write the startup code themselves by referring...
虚V界 ARM Technology
[Mill Edge AI Computing Box FZ5 Review] 2019DAC Conference Target Detection Network Skynet Reproduction
Many excellent projects have been launched to accelerate deep learning using FPGA , such as Xilinx 's official BNN and QNN open source projects. At the same time, the Design Automation Conference (DAC...
zzx1997 Embedded System
About synchronization issues
I would like to ask you a question. Background: There is a receiver and a sender. The receiver wants to receive a piece of data sent by the sender. (Since the sender does not know when to send the dat...
24432972 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2492  2460  1525  575  2103  51  50  31  12  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号