EEWORLDEEWORLDEEWORLD

Part Number

Search

2200SAG1504B3LB

Description
Strain Guage Sensor, Absolute, 0Psi Min, 150Psi Max, 0.15%, 0-10V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200SAG1504B3LB Overview

Strain Guage Sensor, Absolute, 0Psi Min, 150Psi Max, 0.15%, 0-10V, Cylindrical

2200SAG1504B3LB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset0V
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0-10V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type7/16 MALE
Maximum pressure range150 Psi
Minimum pressure range
Pressure sensing modeABSOLUTE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeDIN 9.4MM W/O MATE
Base Number Matches1
Ethernet Tutorial Episodes 1-4
Ethernet Tutorial Episodes 1-4...
bobozhu83610 MCU
PLC learning little by little 1
By the way, I used Siemens S7-200 to learn PLC.I have basically finished reading the PLC materials these days, and I want to find two big questions to practice, but yesterday I was really hurt by this...
fangzhh2008 Industrial Control Electronics
Homemade RC522 RFID card reader module complete set of information
A complete set of information on the self-made RC522 radio frequency card reader module, including PCB and schematic diagram...
问路者 NXP MCU
Hey guys!! I have a question about the s3c44b0 development board! I have been working on it for 4 or 5 days and it is still not fixed!
Sorry, I have to complain first. I want to vent my personal feelings! I bought an innovative arm7 s3c44b0 development board and I feel that the supporting documents of their products are too poor. The...
54288519 Embedded System
The serial port can only send but not receive
I moved the serial port driver of Adeneo's AT9261 BSP to AT9263 BSP (because AT9263 BSP seems to be able to open only one serial port), that is, I replaced the corresponding files in PLATFORM\AT91SAM9...
renjg888 Embedded System
Does anyone know why the jlink and stm32 can be recognized and erased normally but the program cannot be written?
[[i]This post was last edited by ssawee on 2011-1-8 12:25[/i]]...
ssawee stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 246  1611  931  2398  384  5  33  19  49  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号