8
7
6
5
4
REV
A
3
DESCRIPTION
INITIAL RELEASE
2
REVISIONS
DATE
1
APPROVED
D.GRIFFIN
10/9/12
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF L-COM, INC. ANY REPRODUCTION IN PART OR WHOLE
WITHOUT THE WRITTEN PERMISSION OF L-COM, INC. IS PROHIBITED.
RoHS Compliant
D
D
LENGTH
2X, SHRINK TUBE,
BLACK
C
195R SERIES, 50 OHM LOW-LOSS COAXIAL CABLE
JACKET: PVC, BLACK
TNC PLUG
REVERSE POLARITY
RIGHT ANGLE
CONNECTOR
LENGTH CODE CHART
C
TYPE N-MALE
STRAIGHT CRIMP
CONNECTOR
B
CABLE# & LENGTH
CA-RTPRNMAXXX
CA-RTPRNMANXX
CA-RTPRNMAMXX
CA-RTPRNMAXMX
LENGTH SYMBOL
WHERE XXX = LENGTH IN FEET
WHERE NXX = LENGTH IN INCHES
WHERE MXX = LENGTH IN METERS
WHERE XMX = LENGTH IN DECIMAL METERS
EXAMPLES OF PART# USED
CA-RTPRNMA010 (10 FEET)
CA-RTPRNMAN16 (16 INCHES)
CA-RTPRNMAM07 (7 METERS)
CA-RTPRNMA3M5 (3.5 METERS)
B
NOTES:
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES [mm]
OVERALL CABLE LENGTH TOLERANCE:
≤12 [305] = +1 [25] / -0
>12 [305] ≤60 [1524] = +2 [51] / -0
>60 [1524] ≤120 [3048] = +4 [102] / -0
>120 [3048] ≤300 [7620] = +6 [152] / -0
>300 [7620] = +5% / -0%
ALL OTHER DIMENSIONAL TOLERANCES:
.X = ± .2
.XX = ± .02
.XXX = ±.005
PROJECTION
APPROVALS
DRAWN BY
DATE
10/9/12
10/9/12
10/9/12
PRODUCT DESCRIPTION
CATEGORY
A
1. CABLE ASSEMBLY SHALL BE TESTED FOR CONTINUITY.
2. CABLE ASSEMBLY SHALL RECEIVE INSERTION LOSS TEST
PER L-COM SPECIFICATIONS.
3. CABLE ASSEMBLY SHALL BE INDIVIDUALLY PACKAGED IN
ACCORDANCE WITH L-COM SPECIFICATION PS-0031.
D.FRISIELLO
CHECKED BY
45 BEECHWOOD DRIVE
NORTH ANDOVER, MA
01845
T.VADEN
APPROVED BY
P.PESA
COAXIAL
CA,195 RP-TNC R/A PLUG/NM
SIZE
A
CONFIGURATION DETAILS OF
UNDIMENSIONED FEATURES
MAY VARY
COLOR VARIATIONS
MAY OCCUR
A
43321
2
FSCM NO.
DWG. NO.
CA-RTPRNMA
1
REV.
SHEET 1 OF 1
SCALE: NONE
CAD FILE:
CA-RTPRNMA.SLDDRW
A
8
7
6
5
4
3