EEWORLDEEWORLDEEWORLD

Part Number

Search

55A1842-4

Description
SPECIFICATION CONTROL DRAWING
File Size554KB,1 Pages
ManufacturerBRIGHT
Websitehttp://www.brightled.co.kr/
Download Datasheet View All

55A1842-4 Overview

SPECIFICATION CONTROL DRAWING

SPECIFICATION CONTROL DRAWING
TITLE
55A1842
Date
FOUR CONDUCTOR CABLE, RADIATION-CROSSLINKED, MODIFIED ETFE INSULATED,
SHIELDED, JACKETED, NORMAL WEIGHT, 600 VOLT
02-26-04
Revision
B
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
COMPONENT WIRE - 55A0812
SHIELD - SILVER-COATED COPPER
JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
55A1842-26-*
55A1842-24-*
55A1842-22-*
55A1842-20-*
55A1842-18-*
55A1842-16-*
55A1842-14-*
55A1842-12-*
55A1842-10-*
55A1842- 8-*
55A1842- 6-*
55A1842- 4-*
CONDUCTOR
SIZE
(AWG)
26
24
22
20
18
16
14
12
10
8
6
4
SHIELD
SIZE
(AWG)
38
38
38
38
38
38
38
38
36
34
34
34
JACKET THICKNESS
(inches)
MINIMUM
.006
.006
.006
.006
.006
.007
.007
.007
.008
.009
.012
.016
NOMINAL
.008
.008
.008
.008
.008
.009
.009
.009
.010
.011
.014
.018
OUTSIDE DIAMETER
(inches)
NOMINAL
.130
.142
.154
.173
.202
.221
.262
.304
.365
.520
.637
.812
MAXIMUM
.150
.165
.179
.202
.237
.259
.308
.357
.430
.613
.753
.960
MAXIMUM
WEIGHT
(lbs/1000 ft.)
14.7
18.0
22.5
30.0
42.2
51.4
74.0
104.
162.
305.
455.
743.
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 7 hours
BLOCKING: 200 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
FLAMMABILITY: Procedure 1,
3 seconds (maximum); 3 in. (maximum);
no flaming of facial tissue
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
JACKET FLAWS:
Spark Test, 1000 volts (rms)
Impulse Dielectric Test, 6.0 kV (peak)
NOTE: Nominal values are for information only.
Nominal values are not requirements.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
R
Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
LIFE CYCLE: 230 ± 3°C for 500 hours
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND TEST(Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
PART NUMBER:
The "*" in the part numbers above shall be replaced
by color code designators with a slash separating
the component wire colors and a dash separating
the component wire colors from the jacket color.
Colors shown do not necessarily reflect the sequence of
manufacturing.
1/ Example: AWG 20, brown, red, orange and yellow
component wires; white jacket:
55A1842-20-1/2/3/4-9
Page 1 of 1
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Measures to improve the accuracy of standard orifice flowmeter
Measures to improve the accuracy of standard orifice flowmeters In order to improve the accuracy of standard orifice flowmeters, the following measures can be taken: 1. Manufacturing and installation ...
njjnyb DIY/Open Source Hardware
Keil+Jlink cannot debug
I want to use Keil+Jlink to debug the LM3S8962 development board I have, but there is no response when I plug it in, and it always says download failed. I looked for a solution online, tried it, but i...
莫妮卡 Microcontroller MCU
Single chip electronic scale
I am making a microcontroller electronic scale, please give me some advice....
alert4 Embedded System
Global Semiconductor Industry Trends PK
Different views on the global semiconductor industry situation 2006-6-19The recent spring forecast by WSTS (World Semiconductor Trade Statistics), a well-known American organization, indicated that th...
ehk RF/Wirelessly
I would like to ask you guys, how to find x25045 and m24c01bn6 in the protel schematic?
I would like to ask you, how to find x25045 and m24c01bn6 in the protel schematic? Please give me detailed instructions? :Laugh:...
假面的告白 PCB Design
Electronic combination lock design
Electronic password lock, that is, you can set the password, which is quite interesting~~...
xianghong123 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 548  1440  2245  2000  2915  12  29  46  41  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号