EEWORLDEEWORLDEEWORLD

Part Number

Search

LDEEA2150MA0N00

Description
Film Capacitor, Polyethylene Naphthalate, 100V, 20% +Tol, 20% -Tol, 0.015uF, Surface Mount, 1206
CategoryPassive components    capacitor   
File Size2MB,19 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance  
Download Datasheet Parametric View All

LDEEA2150MA0N00 Overview

Film Capacitor, Polyethylene Naphthalate, 100V, 20% +Tol, 20% -Tol, 0.015uF, Surface Mount, 1206

LDEEA2150MA0N00 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerKEMET
package instruction, 1206
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresRATED AC VOLTAGE (V): 63
capacitance0.015 µF
Capacitor typeFILM CAPACITOR
dielectric materialsPOLYETHYLENE NAPHTHALATE
high1.2 mm
length3.3 mm
Installation featuresSURFACE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
Package formSMT
method of packingTR
positive tolerance20%
Rated (AC) voltage (URac)63 V
Rated (DC) voltage (URdc)100 V
GuidelineAEC-Q200
size code1206
surface mountYES
Terminal shapeWRAPAROUND
width1.7 mm
General Purpose, High Stability and AC Line EMI Suppression
LDE Series Unencapsulated Stacked Chip,
Size 1206 – 6054, 50 – 1,000 VDC
Overview
Polyethylene naphthalate (PEN) film capacitor for surface
mounting.
Applications
Typical applications include bypassing and signal coupling. LDE
is a general purpose series designed for the highest reliability
and high temperature service.
Benefits
Rated voltage: 50 – 1,000 VDC
Rated voltage: 40 – 250 VAC
Capacitance range: 0.001 – 4.7 µF
EIA size: 1206 – 6054
Capacitance tolerance: ±10%, ±20%, ±5% on request
Climatic category: 55/125/56
RoHS Compliant and lead-free terminations
Operating temperature range of -55˚C to +125˚C
Part Number System
LDE
Series
Metallized
PEN
C
Rated Voltage
(VDC)
C = 50
D = 63
E = 100
I = 250
M = 400
P = 630
Q = 1000
C
Size Code
See
Dimension
Table
2560
Capacitance Code (pF)
Digits 2 – 4 indicate the
first three digits of the
capacitance value.
First digit indicates the
number of zeros to be
added.
M
Capacitance
Tolerance
K = ±10%
M = ±20%
J = ±5% on
request
A5
Version
A5 = Standard
A0 = Miniature
N
Packaging Code
See Ordering
Options Table
00
Internal Use
00 (Standard)
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
F3078_LDE • 4/4/2013
1
Microcontroller discharge problem
When making a product, I found a problem. After turning off the power and restarting it within a short period of time, I found that there was residual charge. Is there any way to discharge it?...
sunyitui Embedded System
MC55 sends AT commands but no response, please help
I use the Siemens MC55 module, and use a laptop to connect to the module via USB to RS232. The peripheral circuit of MC55 is built by myself. After powering on, VDD shows 2.88V, CCVCC is powered on no...
zhangxi004 Embedded System
SJA1000 English and Chinese Application Guide
The application guide of SJA1000 in Chinese and English. Friends who often use CAN can take a look. I hope it will be helpful....
mzsahj Automotive Electronics
EMC test and other test items
EMC test: As more and more electronic products adopt low-power, high-speed, and highly integrated LSI circuits, these systems are more vulnerable to electromagnetic interference than ever before. At t...
czf0408 LED Zone
Ruan Gong's MCU programming experience: how to make stable MCU programs and host computer programs to prevent jamming, js and other experiences; Ruan Ding...
Ruan Gong's MCU Programming Experience Collection V2.1: How to Make Stable MCU Programs, Ruan Dingyuan:================================================== =================The problem of 0.99999 being ...
net2uizoo stm32/stm8
Blood pressure sensor circuit, filter and amplifier circuit based on MAX4472
As shown in the figure below, this circuit uses BP01 pressure sensor and MAX4472 operational amplifier. BP01 pressure sensor is specially designed for blood pressure detection and is mainly used in po...
ok123 Medical Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 421  1550  2352  2043  703  9  32  48  42  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号