High Reliability COTS (CWR11 Style) – T493 Series COTS Space Grade
Table 1A – Ratings & Part Number Reference
Rated
Rated
Case Code/
KEMET Part Number
Voltage Capacitance Case Size
V
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
V
µF
2.2
3.3
4.7
6.8
6.8
10.0
10.0
15.0
15.0
22.0
22.0
22.0
33.0
33.0
47.0
47.0
68.0
68.0
68.0
100.0
100.0
150
150
220
330
330
1.5
2.2
3.3
4.7
4.7
6.8
6.8
10
10
15
15
15
22
22
33
33
47
47
47
68
µF
KEMET/EIA
A/3216–18
A/3216–18
A/3216–18
A/3216–18
B/3528-21
A/3216–18
B/3528-21
A/3216–18
B/3528-21
A/3216–18
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
D/7343-31
C/6032-28
D/7343-31
C/6032-28
D/7343-31
D/7343-31
D/7343-31
X/7343-43
A/3216–18
A/3216–18
A/3216–18
A/3216–18
B/3528-21
A/3216–18
B/3528-21
A/3216–18
B/3528-21
A/3216–18
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
B/3528-21
C/6032-28
D/7343-31
C/6032-28
KEMET/EIA
(See below for
part options)
T493A225(1)004(2)(3)(4)(5)(6)
T493A335(1)004(2)(3)(4)(5)(6)
T493A475(1)004(2)(3)(4)(5)(6)
T493A685(1)004(2)(3)(4)(5)(6)
T493B685(1)004(2)(3)(4)(5)(6)
T493A106(1)004(2)(3)(4)(5)(6)
T493B106(1)004(2)(3)(4)(5)(6)
T493A156(1)004(2)(3)(4)(5)(6)
T493B156(1)004(2)(3)(4)(5)(6)
T493A226(1)004(2)(3)(4)(5)(6)
T493B226(1)004(2)(3)(4)(5)(6)
T493C226(1)004(2)(3)(4)(5)(6)
T493B336(1)004(2)(3)(4)(5)(6)
T493C336(1)004(2)(3)(4)(5)(6)
T493B476(1)004(2)(3)(4)(5)(6)
T493C476(1)004(2)(3)(4)(5)(6)
T493B686(1)004(2)(3)(4)(5)(6)
T493C686(1)004(2)(3)(4)(5)(6)
T493D686(1)004(2)(3)(4)(5)(6)
T493C107(1)004(2)(3)(4)(5)(6)
T493D107(1)004(2)(3)(4)(5)(6)
T493C157(1)004(2)(3)(4)(5)(6)
T493D157(1)004(2)(3)(4)(5)(6)
T493D227(1)004(2)(3)(4)(5)(6)
T493D337(1)004(2)(3)(4)(5)(6)
T493X337(1)004(2)(3)(4)(5)(6)
T493A155(1)006(2)(3)(4)(5)(6)
T493A225(1)006(2)(3)(4)(5)(6)
T493A335(1)006(2)(3)(4)(5)(6)
T493A475(1)006(2)(3)(4)(5)(6)
T493B475(1)006(2)(3)(4)(5)(6)
T493A685(1)006(2)(3)(4)(5)(6)
T493B685(1)006(2)(3)(4)(5)(6)
T493A106(1)006(2)(3)(4)(5)(6)
T493B106(1)006(2)(3)(4)(5)(6)
T493A156(1)006(2)(3)(4)(5)(6)
T493B156(1)006(2)(3)(4)(5)(6)
T493C156(1)006(2)(3)(4)(5)(6)
T493B226(1)006(2)(3)(4)(5)(6)
T493C226(1)006(2)(3)(4)(5)(6)
T493B336(1)006(2)(3)(4)(5)(6)
T493C336(1)006(2)(3)(4)(5)(6)
T493B476(1)006(2)(3)(4)(5)(6)
T493C476(1)006(2)(3)(4)(5)(6)
T493D476(1)006(2)(3)(4)(5)(6)
T493C686(1)006(2)(3)(4)(5)(6)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Maximum/5 Min
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.9
0.9
0.9
1.3
1.3
1.9
1.9
2.7
2.7
2.7
4.0
4.0
6
6
8.8
13.2
13.2
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.9
0.9
0.9
1.4
1.4
2
2
2.9
2.9
2.9
4.1
µA @ +20ºC
Maximum/5 Min
DF
Standard
ESR
Low ESR
Moisture
Sensitivity
Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Temperature
≤ 260ºC
% @ +20ºC
Ω @ +20ºC
Ω @ +20ºC
120 Hz Maximum 100 kHz Maximum 100 kHz Maximum
6.0
8.0
6.0
6.0
8.0
4.0
6.0
8.0
3.5
6.0
6.0
3.0
6.0
5.5
2.0
6.0
6.0
2.0
6.0
3.5
1.2
6.0
4.0
1.5
6.0
3.5
1.2
6.0
4.0
1.5
6.0
3.5
0.6
6.0
1.8
0.5
6.0
3.5
0.5
6.0
1.8
0.5
6.0
3.0
0.5
6.0
1.8
0.5
6.0
3.5
2.0
6.0
1.6
0.25
6.0
0.8
0.2
8.0
1.2
0.2
8.0
0.8
0.2
8
1.2
0.3
8
0.8
0.15
8
0.9
0.7
8
0.7
0.15
8
0.5
0.2
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
6
5.5
6
3.5
4
3.5
4
3.5
1.8
3.5
1.8
3
1.8
3.5
1.6
0.8
1.2
6
6
6
3.5
3.5
2
1.2
2
1
1.5
0.7
0.6
0.6
0.5
0.6
0.3
2
0.25
0.22
0.2
% @ +20ºC
Ω @ +20ºC
Ω @ +20ºC
120 Hz Maximum 100 kHz Maximum 100 kHz Maximum
Rated
Voltage
Rated
Capacitance
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
Standard ESR
Low ESR
Moisture
Sensitivity
(1) To complete KEMET part number, insert M for ±20%, K for ±10%. Designates Capacitance tolerance.
(2) To complete KEMET part number, insert C (0.01%/1,000 hours). Designates Reliability Level.
(3) To complete KEMET part number, insert H = Solder Plated or T = 100% Tin (Sn). Designates Termination Finish.
(4) To complete KEMET part number, insert 61 = None, 62 = 10 cycles +25°C, 63 = 10 cycles -55°C +85°C after Weibull, 64 = 10 cycles -55°C +85°C before
Weibull or 65 = Both. Designates Surge current option.
(5) To complete KEMET part number, insert 1 = Standard ESR, 2 = Low ESR. Designates ESR option.
(6) To complete KEMET part number, insert A = Option 1, B = Option 2 or C = Option 3. Designates Test Option. See Space Grade Test Methods chart for more
information.
Refer to Ordering Information for additional detail.
Power Stage DesignerTM is a JAVA-based tool (requires JAVA 8 or OpenJDK 8) that helps engineers speed up the power supply design process by calculating voltages and currents for 20 topologies based on...
rt, let A be the master station, B and C be slave stations, and S be the mobile sound source. By measuring the time difference ΔtAB from S to station A and station B, and the time difference ΔtAC from...
SPI and DMA initialization are automatically generated by STM32CUBEMX. The external memory is LY68L6400. I use HAL_SPI_Transmit(hspi2,(uint8_t * )TX_data, 1020, 0xfffffff);
The function writes data to...
This article describes the best ways to improve performance, encoding success rates, and increase uptime with RFID smart labels. It can help you get more value from your smart label printing system by...
Keysight Technology Award-winning Live Broadcast | Thanksgiving Month Opening Ceremony - Oscilloscope Lecture Hall Registration Starts~Click here to registerLive broadcast time: 10:00-12:00, June 6, 2...
Hello everyone! The stator phase sequence is fixed, the synchronous motor excitation is reversed, and the rotor rotation direction remains unchanged. What is the reason? Is it because the speed of the...
With the promotion of the construction of intelligent communities in the country, anti-theft systems have become essential equipment for intelligent communities. Especially in recent years, the urg...[Details]
This program is written to simulate the serial port hardware mechanism. When used, a timed interrupt can be set with a time interval of 1/4 baud rate. The receiving function is called once for ea...[Details]
In
circuit design,
current
measurement
is widely used, and the main fields are divided into three categories: in measurement,
the electric meter
is used to measure the curre...[Details]
As a wireless broadband metropolitan area network standard, WiMAX technology has greater advantages than previous 3.5GHz MMDS products in terms of non-line-of-sight transmission and spectrum utiliz...[Details]
0 Introduction
With the development of my country's economy, the number of motor vehicles continues to increase. The growth of existing roads and other hardware facilities can no longer meet t...[Details]
In recent years, the market for mobile/portable devices such as smartphones and laptops has continued to grow rapidly. While these products continue to integrate more new features to enhance the ...[Details]
1. Introduction
Light control circuit plays a vital role in urban street lamps or corridor lighting. With light control circuit, the lights can be automatically turned on and off according to ...[Details]
As cellular phones become more advanced, the power consumption of the system during operation and the power consumption during standby are also increasing. Therefore, the power management design of...[Details]
DSP (digital signal processor) is used more and more frequently in today's engineering applications. There are three main reasons for this: first, it has powerful computing power and is capable of ...[Details]
Images in science fiction movies often break through the limits of reality, such as in the movie "Minority Report." Tom Cruise uses a multi-touch screen to browse information. Capacitive sensing te...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
Xiaomi, a well-known Internet phone in mainland China, won a million-unit order contract from China Unicom on November 20 last year, which made Xiaomi famous in mainland China. In April this year...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
We know that the inverter consists of two parts: the main circuit and the control circuit. Due to the nonlinearity of the main circuit (switching action), the inverter itself is a source of harmoni...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]