EEWORLDEEWORLDEEWORLD

Part Number

Search

TLGK-DG-LTA113-TR-BR/6V

Description
Rocker Switch, SPST, Latched, Quick Connect Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size189KB,2 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

TLGK-DG-LTA113-TR-BR/6V Overview

Rocker Switch, SPST, Latched, Quick Connect Terminal, Rocker Actuator, Panel Mount

TLGK-DG-LTA113-TR-BR/6V Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width25.24 mm
body height20.62 mm
Body length or diameter28.44 mm
Contact (AC) maximum rated R load10A@125VAC
Maximum contact current (AC)10 A
Maximum contact voltage (AC)125 V
Electrical life50000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial numberTLG
Installation featuresPANEL MOUNT
Maximum operating temperature66 °C
Minimum operating temperature
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeROCKER SWITCH
Termination typeQUICK CONNECT
Carling
Technologies
TLG-Series Rocker Switches
TLG-Series Rocker Switches
The TLG-Series Mini Tippette snap-in rocker switches are
single pole, rocker or paddle actuated with an adjacent indi-
cator light. These single-actuator-switches are AC rated to
20 amps and are also suitable for low voltage DC applica-
tions, in a wide range of markets including Appliance,
HVAC, Food service and Transportation.
Dielectric Strength
UL/CSA:
1000V - live to dead metal parts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 150°F (0°C to +65.6°C)
.069[1.75] DIA
.156[1.75] DIA
.055[1.75] DIA
6.000[152.40]
.375[9.52]
.250[6.35]
.500[12.70]
.187[4.74]
INTEGRATED WIRE LEAD
(no exposed conductors)
1.155[29.33]
.390[9.90]
.050[1.27]
1.240[31.49]
.250[6.35]
.250[6.35]
.250 TAB (Q.C.)
SOLDER LUG
.187 TAB (Q.C.)
TERMINAL TYPE
.220[5.59]
.812[20.62]
.275[6.98]
.375[9.52]
1.000[25.40]
1.120[28.44]
PADDLE
SHORT PADDLE
MOUNTING HOLE
Panel Thickness:
.020[.508] min. to
.250[6.35] max.
.520[13.20]
1.125[28.57]
.994[25.24]
TLG G
-
D R
-
TA 20 1
-
T B
-
B
1
Base Part Number
2
Circuit
3
Lens
Design
4
Lens Color
5
Basic Switch
Number
6
Rating
7
Termination
/ Function
8
Actuator
Style
9
Actuator
Color
10
Base Color
/
125N
11
Lens Color
12
Lamp Voltage
1 BASE PART NUMBER: SERIES
TLG
Single Pole with adjacent Indicator Light
2 CIRCUIT
1
See Circuit Designation Chart Page 17.
3 LENS DESIGN
D
diamond
L
long Line
4 LENS COLOR
A
amber
C
clear
7 TERMINATION/FUNCTION
solder lug
.250 tab QC .187 tab QC
ON-NONE-OFF
0
1
3
(ON)-NONE-OFF
A
B
D
ON-NONE-(OFF)
L
M
R
ON-NONE-ON
0
1
3
ON-NONE-(ON)
A
B
D
ON-OFF-ON
0
1
3
8 ACTUATOR STYLE
P
paddle
PS
T
wire leads
5
F
T
5
F
5
short paddle
rocker
G
R
green
red
W
white
5 BASIC SWITCH NUMBER
4
TA
ON-NONE-OFF
TB
ON-NONE-ON
9 ACTUATOR COLOR
3
unlighted
B
black
W
white
TC
ON-OFF-ON
LTA
OFF-NONE-ON, lighted
10 BASE COLOR
3
B
black
11 LENS COLOR
2,4
A
amber
C
clear
12 LAMP VOLTAGE
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
lighted
2
A
amber
C
clear
G
green
LU
blue
R
red
6 RATING
10
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
11
5A 250VAC, 10A 125VAC, 5A 125VAC L
20
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
21
10A 250VAC, 15A 125VAC
22
10A 250VAC, 15A 125VAC, 20A 125-250VAC H, 3/4HP 125-250VAC
NOTES:
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same direction
as the punch. (Burr on bottom.) Test cut hole in actual material.
1 Available with circuits G, H, I, J, K.
2 Neon lamps (125V or 250V) not recommended with green or blue actuators and lenses.
3 Custom colors are available. Consult factory.
4 Specify lens color only if Basic Switch Number is LTA (lighted). If not, leave blank.
( ) Indicates momentary function.
W
white
G
LU
green
blue
R
W
red
white
neon
2
125N
125 volt neon
250N
250 volt neon
16
www.carlingtech.com
Power Management Guide 2013
Texas Instruments (TI) has a full range of high-performance products that can provide complete power solutions. From standard linear regulators to high-efficiency DC/DC converters and battery manageme...
德州仪器_视频 Analogue and Mixed Signal
I have just developed an enterprise project management software. Please give me some suggestions!
I have just developed an enterprise project management software, which is mainly for commercial enterprises, managing sales and procurement projects, and the management of various project expenses. It...
qjc221 Embedded System
How to compile winpcap for ce?
This is my first time using WinPcap for CE, and there are many things I don't understand. I downloaded the source code for WinPcap for CE, but the official website says I need to compile it myself. I ...
loolen Embedded System
EVC4 static library compilation problem
In EVC4, I selected the dynamic link library "use MFC in a shared DLL" to compile and generate the application. After XXX.exe runs on the target board, the following error is prompted: "Cannot find XX...
zhousw08 Embedded System
I want the principle circuit diagram of the switching power supply for the 2007 National Electronic Design Competition (Question E).
[i=s] This post was last edited by paulhyde on 2014-9-15 03:20 [/i] Please help me. I need the schematic diagram of the switching power supply from the 2007 National Electronic Design Competition (Top...
leowang029 Electronics Design Contest
About the calibration method of RTC in STM32 (transfer)
I have read some posts about RTC calibration recently and found that many people are confused. I also implemented RTC calibration in STM32 recently. I will share some experience. These may be a bit co...
fuqing5542 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 472  1364  1358  916  1505  10  28  19  31  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号