EEWORLDEEWORLDEEWORLD

Part Number

Search

GLC75H

Description
75 Watt Multiple Output Global Performance Switchers
File Size272KB,2 Pages
ManufacturerSLPOWER
Websitehttp://www.slpower.com/
Download Datasheet Compare View All

GLC75H Overview

75 Watt Multiple Output Global Performance Switchers

GLOBAL PERFORMANCE SWITCHERS
GLC75 Commercial/GLM75 Medical
75 Watt Multiple Output Global Performance Switchers
FEATURES:
• Cost-effective multiple output power source
• Universal input 90-264 Vac
• 7.00”x 4.25”x 1.30” (Meets 1U height)
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
• Complies with EN61000-3-2 Class A
• Also available in single output versions
• Commercial UL1950 3rd Edition, CSA22.2 No. 950 and
EN60950-1 approvals
• Medical Approved to UL2601-1,
CSA22.2 No. 601.1-M90, and IEC/EN60601-1
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load not to
exceed 2.3 A.
Output Power
Normal continuous output power is 75 W for unrestricted natural convection
cooling or 110 W with 26 cfm airflow. During peak load conditions output
regulation may exceed total regulation and noise limits.
Output Regulation
Measured by ±40% load change from 60% rated load with all other outputs
at 60% rated load and input voltage change from minimum to maximum rat-
ings. Output #1 requires 1A minimum load for proper regulation of other
outputs. Initial set tolerance is measured with all outputs at 60% of full rated
load. Output #2 requires 0.5A minimum load for proper regulation.
Overload Protection
Factory set to begin power limiting at approximately 120 W. Fully protected
against short circuit and output overload. Short circuit protection is cycling
type power limit.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with
noise probe directly across output terminals of the power supply.
Transient Response
Main Output: 500μSec typical response time for return to within 0.5% of final
value for a 50% load step change, ∆i/∆t<0.2A/μSec. Maximum voltage devia-
tion is 3.5%.
Overvoltage Protection
Built in on V1 with firing point set per table. OVP firing reduces output #1 and
#2 to less than 50% of nominal voltage in 50 ms.
Voltage Adjust
Factory set on standard unit; however, optional potentiometer (“-V” suffix)
adjusts voltage from 4.7 V to OVP point (6.2 V nominal) on the +5 V output.
Note: Output #1 must not be more than 1% below nominal to achieve full
output voltage range on Output #2. Output regulation limits in some models
may be exceeded when the main output is adjusted beyond +1% of nominal
voltage. High voltage settings may degrade the reliability of the unit due to
excessive power dissipation in some outputs.
Efficiency
68% -78% depending on model and load distribution.
Input Protection
Internal ac fuse provided on all units. Designed to blow only if a catastrophic
failure occurs in the unit.
Inrush Current
Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac
half-cycle under cold start conditions will not exceed 37 A.
Hold Up Time
20 ms minimum from loss of ac input power at full load, nominal line (120 Vac).
Temperature Coefficient
0.03%/°C typical on all outputs.
Power Fail
A standard TTL or CMOS compatible output goes low (< 0.5 V) 5ms before output
voltage drops more than 4% below nominal voltage upon loss of ac power. Signal
is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line
impedance and distortion. Other settings are available through adjustment of
built-in potentiometer (consult factory for assistance). Output will stay low for 20
ms minimum.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GLC75
Conducted Emissions GLM75
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B: FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A
Commercial Safety
All GLC models are approved to UL1950 3rd Edition, CSA22.2 No. 950, and
EN60950-1.
Medical Leakage Current
70 μA 264 V @ 50 Hz (normal conditions).
Medical Safety
GLM models are approved to UL2601-1, CSA22.2 No. 601.1M90, IEC/EN60601-1. CB
Report available.
All specifications are typical at nominal input, full load at 25
O
C unless otherwise stated

GLC75H Related Products

GLC75H GLC75 GLC75A GLC75B GLC75C GLC75D GLC75E GLC75F GLC75J GLC75P
Description 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers 75 Watt Multiple Output Global Performance Switchers
Learn LLC switching power supply calculation from senior engineers
[i=s]This post was last edited by ohahaha on 2021-5-20 15:02[/i]The new infrastructure that conforms to the times includes: 5G infrastructure, ultra-high voltage, high-speed rail, new energy vehicle c...
ohahaha Power technology
2013 Inverted Pendulum
mpu6050 detects posture. Stepper motor is used as driver...
熊猫大叔的胸毛 Download Centre
Embedded operating system NAND flash file system
There are many file systems for front flash, and the most commonly used one is the JFFS2 file system. The JFFS2 file system based on NOR flash can be said to be relatively mature, and the JFFS2 file s...
songbo Embedded System
Today the monitor notified the Polytechnic that there will be a school celebration~~
The monitor is counting everyone's work and contact information to see if they will go to the school anniversary.Haha, think about how easy it was to get together when we were in school. Now it has be...
soso Talking
Problems that should be paid attention to in the development and design of TMS320C2XX
1 IntroductionHigh-speed digital signal processor is one of the hot technologies in the current information industry. The use of the most advanced DSP will undoubtedly make the developed products more...
灞波儿奔 Microcontroller MCU
How to burn the program into the external NOR flash?
Hello, sir: I use STM32F103ZC chip, and IAR EWARM for development. I use ICP to burn the program into the on-chip NOR flash, which is very convenient, but now I want to burn the program into the off-c...
liangzuolin Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 59  1651  1165  1833  1770  2  34  24  37  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号