BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
TYPES YA-L, YA-L-TC
COPPER COMPRESSION
TERMINAL
UL Listed 90° C,
600 Volts to 35 KV
◆
B
ELECTRO-TIN
PLATED
DIE AND COLOR
CODE INFORMATION
BEVELED
ENTRY
INSPECTION
WINDOW
CRIMP
CABLE
ACCOMMODATION
C-9
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Conductor
Catalog Number
YAV10-45-BOX
YAV10-BOX
YAV10R-BOX
YAV10R3-BOX
YAV10T2-BOX
YAV10T3-45-BOX
YAV10T3-BOX
YAV10T4-BOX
YA8CL1-BOX
YA8CL1-45
YA8CL1-90
YA8CL2-BOX
YA8CL2-45
YA8CL2-90
YA8CL3-BOX
YA8CL3-45
YA8CL3-90
YA8CL4-BOX
YA8CL4-45
YA8CL4-90
YA8CL-BOX
YA8CL-45
YA8CL-90
YA6CL-BOX
YA6CL-45
YA6CL-90
YA6CL1-BOX
YA6CL1-45
YA6CL1-90
YA6CL3-BOX
YA6CL3-45
YA6CL3-90
***
Fig #
AWG
1
1
#14-#10
3
STR
3
1
#12-#10
2
SOL
1
1
1
2
3
1
2
#8 AWG
3
1
#8 WELD
2
3
37/24
1
2 #6 SOLID
3
1
2
3
1
2
3
1
2
#6 AWG
3
1
2
3
MM
2
Stud
Hole
Size
8-10
6
1/4
5/16
1/4
1/4
3/8
1/4
Tongue
Width
.38
.47
.53
.47
.47
.56
.44
(B)
.405
.405
.375
.405
.38
.405
.405
.38
.44
Figure
Dimensions
(T)
.058
.058
.058
.047
.047
.047
.047
.047
.08
Dieless
(L)
.92
1.02
.77
.83
1.12
1.10
1.10
1.18
1.26
1.24
.80
1.38
1.34
.92
1.51
1.45
1.04
1.76
1.67
1.28
1.16
1.16
.71
1.18
1.08
.81
.99
.89
.72
1.24
1.06
.93
(# of crimps)
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
Wire
Color Die Strip
Code Index Length
Y8MRB-1 (1)
-
-
-
-
7/16
5/16
†
10
.52
.44
.06
3/8
.58
.44
.06
1/2
.71
.44
.05
Y1MR (1)
Y8MRB-1 (1)
W8CVT (1) W8CVT (1)
Y2MR (1)
W8CRT (1) W8CRT (1)
MY29-3 (1)
X8CRT (1) X8CRT (1)
MY29-11 (1)
MRC840 (1)
U8CRT (1)
Red
49
7/16
8-10
.41
.44
.08
1/4
.45
.41
.41
.42
.52
.54
.54
.54
.54
.54
.08
.09
.09
.09
.07
8-10
Y1MR (1)
W5CVT (1) W5CVT (1)
MY29-3 (1)
W5CRT (1) W5CRT (1)
MY29-11 (1)
X5CRT (1) X5CRT (1)
MRC840 (1)
X8CART (1) X8CART (1)
Y2MR (1)
U5CRT (1)
Blue
7
7/8
5/16
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
† The MM
2
conductor size listed is for both Class 2 and
Class 5 conductor.
▲
See tooling section of this catalog for complete tool and die
listings.
◆
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(Continued)
Conductor
Catalog Number
YA6CL4-BOX
C-10
YA6CL4-45
YA6CL4-90
YA6CL6-BOX
YA6CL6-45
YA6CL6-90
YA5CL-BOX
YA5CL-45
YA5CL-90
YA4CL-BOX
YA4CL-45
YA4CL-90
YA4CL1-BOX
YA4CL1-45
YA4CL1-90
YA4CL3-BOX
YA4CL3-45
YA4CL3-90
YA4CL4-BOX
YA4CL4-45
YA4CL4-90
YA4CL6-BOX
YA4CL6-45
YA4CL6-90
YA3CL
YA3CL-45
YA3CL-90
YA2CL2-BOX
YA2CL2-45
YA2CL2-90
YA2CL-BOX
YA2CL-45
YA2CL-90
YA2CL4-BOX
YA2CL4-45
YA2CL4-90
YA2CL6-BOX
YA2CL6-45
YA2CL6-90
YA1CL2
YA1CL2-45
YA1CL2-90
YA1CL-BOX
YA1CL-45
YA1CL-90
YA1CL4-BOX
YA1CL4-45
YA1CL4-90
YA1CL6-BOX
YA1CL6-45
YA1CL6-90
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud
Hole
Size
3/8
#6 AWG
1/2
.75
Tongue
Width
.63
Figure
Dimensions
(B)
(T)
(L)
1.28
.54
.06
1.17
1.05
1.60
.54
.12
1.54
1.30
1.65
.81
.07
1.31
.81
1.74
.81
.09
1.44
.84
1.58
.81
.09
1.28
.75
1.92
.81
.08
1.68
.96
1.92
.81
.08
1.68
1.08
2.20
.81
.06
2.02
1.32
1.88
.88
.09
1.76
.98
1.88
.88
.11
1.55
.89
1.93
.88
.11
1.62
1.01
2.06
.88
.11
1.74
1.14
2.32
.88
.09
2.17
1.37
1.81
.88
.10
1.70
.91
1.94
.88
.01
1.82
1.03
2.06
.88
.10
1.95
1.16
2.37
.88
.09
2.22
1.40
Dieless
(# of crimps)
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
Wire
Color Die Strip
Code Index Length
#5 AWG
1/4
.44
W5CVT (1) W5CVT (1)
Y1MR (1) W5CRT (1) W5CRT (1)
MY29-3 (1) X5CRT (1) X5CRT (1)
MY29-11 (1) X8CART (1) X8CART (1)
MRC840 (1)
Y2MR (1) W5CRT (1) W5CRT (1)
W5CVT (1) X5CRT (1)
X5CRT (1) W5CVT (1)
U5CRT (1)
UBCABT (1)
Blue
7
7/8
U5CRT (1)
Blue
7
7/8
1/4
.50
8-10
.50
#4 AWG
5/16
.58
W4CVT (1) W4CVT (1)
W4CRT (1) W4CRT (1)
X4CRT (1) X4CRT (1)
U4CRT (1)
U6CABT (1)
Gray
8
7/8
3/8
.58
1/2
# 3 STR
# 2 SOL
.71
25
5/16
.55
Y1MR (2)
MY29-3 (1)
MY29-11 (1)
MRC840 (1)
Y2MR (2) W3CRT (1) W3CRT (1)
Y644M (1)
U3CRT (1)
White
9
15/16
1/4
.61
5/16
#2 AWG
35
3/8
.61
W2CVT (1) W2CVT (1)
W2CRT (1) W2CRT (1)
X2CRT (1) X2CRT (1)
U2CRT (1)
Brown
10
15/16
.61
1/2
.73
1/4
.68
5/16
#1 AWG
50
3/8
.68
.68
Y1MR (2)
MY29-3 (1) W1CVT (1) W1CVT (1)
MY29-11 (1) W1CRT-1 (1) W1CRT-1 (1)
MRC840 (1) X1CRT-1 (1) X1CRT-1 (1)
Y644M (1)
U1CRT-1 (1)
U4CABT (1)
Green
11
15/16
1/2
.73
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings.
◆
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(Continued)
Conductor
Catalog Number
YA25L2-BOX
YA25L2-45
YA25L2-90
YA25L4-BOX
YA25L4-45
YA25L4-90
YA25L6-BOX
YA25L6-45
YA25L6-90
YA25L-BOX
YA25L-45
YA25L-90
YA26L2-BOX
YA26L2-45
YA26L2-90
YA26L3-BOX
YA26L3-45
YA26L3-90
YA26L-BOX
YA26L-45
YA26L-90
YA26L60
YA26L60-45
YA26L60-90
YA26L6-BOX
YA26L6-45
YA26L6-90
YA26L7-BOX
YA26L7-45
YA26L7-90
YA26LNT516
YA27L2-BOX
YA27L2-45
YA27L2-90
YA27L3
YA27L3-45
YA27L3-90
YA27L4-BOX
YA27L4-45
YA27L4-90
YA27L-BOX
YA27L-45
YA27L-90
YA27LNT38
YA28L17-BOX
YA28L17-45
YA28L17-90
YA28L2-BOX
YA28L2-45
Fig #
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
AWG
***
MM
2
Stud
Hole
Size
1/4
Tongue
Width
.75
Figure
Dimensions
(B)
(T)
(L)
1.84
.88
.12
1.76
.94
2.09
.88
.12
2.01
1.19
2.34
.88
.12
2.26
1.44
1.96
.88
.12
1.88
1.07
1.94
.94
.12
1.78
.96
2.06
.94
.12
1.91
1.09
2.19
.94
.12
2.03
1.21
2.96
.94
.12
2.77
1.89
2.44
.94
.12
2.28
1.46
2.69
.94
.11
2.50
1.71
.94
.13
2.62
2.04
1.00
.13
1.91
.99
2.16
1.00
.13
2.03
1.12
2.29
1.00
.13
1.91
.99
2.54
1.00
.13
2.41
1.49
1.00
.12
2.71
.88
.14
2.64
1.79
1.96
.88
.14
1.89
Dieless
(# of crimps)
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
Wire
Color Die Strip
Code Index Length
C-11
3/8
1/0 AWG
1/2
.75
W25VT (2) W25VT (2)
W25RT (2) W25RT (2)
X25RT (2) X25RT (2)
U25RT (1)
U2CABT (1)
Pink
12
15/16
.75
5/16
.75
1/4
.83
5/16
.83
3/8
2/0 AWG
70
3/4
.83
.96
1/2
.83
MY29-3 (1)
MY29-11 (1)
MRC840 (2)
Y644M (1)
W26VT (2) W26VT (2)
W26RT (2) W26RT (2)
X26RT (2) X26RT (2)
U26RT (1)
Black
13
1
5/8
5/16
1/4
.88
.62
1.00
5/16
3/0 AWG
3/8
.91
.91
W27VT (2) W27VT (2)
W27RT (2) W27RT (2)
X27RT (3) X27RT (3)
U27RT (1)
Orange
14 1-1/16
1/2
3/8
5/8
4/0 AWG
1/4
.91
.76
1.02
W28VT (2) W28VT (2)
W28RT (2) W28RT (2)
X28RT (3) X28RT (3)
U28RT (1)
Purple
15
1-1/8
1.02
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings.
◆
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(Continued)
Conductor
Catalog Number
YA28L2-90
YA28L3-BOX
YA28L3-45
YA28L3-90
YA28L4-BOX
YA28L4-45
YA28L4-90
YA28L56-BOX
YA28L56-45
YA28L56-90
YA28L-BOX
YA28L-45
YA28L-90
YA28LNT38
YA29L2
YA29L2-45
YA29L2-90
YA29L4
YA29L4-45
YA29L4-90
YA29L7
YA29L7-45
YA29L7-90
YA29LTC78
YA29LTC78-45
YA29LTC78-90
YA29LNT38
YA29L-BOX
YA29L-45
YA29L-90
YA30L
YA30L-45
YA30L-90
YA30L1
YA30L1-45
YA30L1-90
YA30L24
YA30L24-45
YA30L24-90
YA30L27
YA30L27-45
YA30L27-90
YA30L28
YA30L7
YA30L7-45
YA30L7-90
YA31L
YA31L-45
YA31L-90
Fig #
AWG
3
1
2
3
1
2
3
4/0 AWG
1
2
3
1
2
3
1
1
2
3
1
2
3
1
2
250 kcmil
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
1
2
3
***
MM
2
Stud
Hole
Size
1/4
5/16
Tongue
Width
1.02
1.02
Figure
Dimensions
(B)
(T)
(L)
.88
.14
1.04
2.08
.88
.14
2.01
1.16
2.21
.88
.14
2.14
1.29
2.90
.88
.13
2.81
1.97
2.46
.88
.14
2.39
1.54
.88
.16
2.79
2.17
1.06
.16
2.07
1.08
2.42
1.06
.16
2.32
1.33
2.30
1.06
.16
2.20
1.20
3.36
1.06
.14
3.23
2.26
1.06
.16
2.96
2.67
1.06
.16
2.57
1.58
2.69
1.03
.16
2.60
1.61
2.31
1.03
.16
2.22
1.24
2.44
1.03
.16
2.35
1.36
3.37
1.03
.16
3.29
2.30
1.03
.16
3.12
2.94
1.03
.16
2.85
1.86
2.75
1.06
.18
2.75
1.65
Dieless
(# of crimps)
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
C-12
Wire
Color Die Strip
Code Index Length
3/8
1.02
3/4
1.05
MY29-3 (1)
W28VT (2) W28VT (2)
MY29-11 (1)
W28RT (2) W28RT (2)
MRC840 (2)
X28RT (2) X28RT (3)
Y644M (1)
U28RT (1)
Purple
15
1-1/8
1/2
3/8
1/4
1.02
.76
1.11
3/8
1.11
5/16
1.11
MY29-3 (1)
W29VT (2)
MY29-11 (1)
X29RT (4)
Y644M (1)
W29VT (2)
W29RT (2)
X29RT (4)
U29RT (1)
Yellow
16
1-1/8
7/8
3/8
1/2
1.11
.96
1.11
1/2
1.20
5/16
1.20
300 kcmil
150
3/8
1.20
W30VT (2)
Y644M (1)
W30VT (2)
W30RT (2)
U30RT (2)
U28ART (2)
White
17 1-1/16
7/8
3/4
5/8
1.20
1.20
1.20
350 kcmil
185
1/2
1.29
W31VT (2)
W31VT (2)
W31RT (2)
U31RT (2)
U29ART (2)
Red
18 1-3/16
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings.
◆
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(Continued)
Conductor
Catalog Number
YA31L11
YA31L11-45
YA31L11-90
YA31L36
YA31L36-45
YA31L36-90
YA31L7
YA31L7-45
YA31L7-90
YA31LNT38
YA32L
YA32L-45
YA32L-90
YA32L1
YA32L1-45
YA32L1-90
YA32L14
YA32L14-45
YA32L14-90
YA32LTC78
YA32LTC78-45
YA32LTC78-90
YA33L
YA33L-45
YA33L-90
YA34L
YA34L-45
YA34L-90
YA34L20
YA34L20-45
YA34L20-90
YA34L37
YA34L37-45
YA34L37-90
YA34L6
YA34L6-45
YA34L6-90
YA34L8
YA34L8-45
YA34L8-90
YA34L9
YA34L9-45
YA34L9-90
YA35L
YA35L-45
YA35L-90
YA36L11
YA36L
YA36L-45
YA36L-90
Fig #
AWG
1
2
3
1
2
350 kcmil
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
2
3
***
MM
2
Stud
Hole
Size
3/8
Tongue
Width
1.29
Figure
Dimensions
(B)
(T)
(L)
2.50
1.06
.18
2.42
1.40
4.02
1.06
.18
4.02
3.94
3.00
1.06
.18
3.00
1.90
1.06
.18
3.37
3.18
1.19
.19
3.08
1.95
2.93
1.19
.19
2.83
1.70
2.68
1.19
.19
2.58
1.45
3.62
1.19
.19
3.52
2.38
3.57
1.50
.21
3.30
2.00
3.37
1.27
.23
3.30
2.03
4.05
1.27
.23
3.99
2.72
2.87
1.27
.23
2.80
1.53
3.12
1.27
.23
3.05
1.78
3.55
1.27
.23
3.49
2.22
3.80
1.27
.23
3.74
2.47
3.81
1.69
.25
3.67
2.08
1.38
.27
3.29
3.72
1.38
.27
3.51
2.11
Dieless
(# of crimps)
B
B
90°
T
45°
B
T
L
T
L
L
Fig. 1
Fig. 2
▲
Installation Tooling
Mechanical
Hydraulic
MD6, OUR840, BCT500HS,
Y35,Y39,Y750,
MD7-34R
Y500CTHS
Y46*, PAT750
Fig. 3
Wire
Color Die Strip
Code Index Length
C-13
185
7/8
1.29
W31VT (2)
W31VT (2)
W31RT (2)
U31RT (2)
U29ART (2)
Red
18 1-3/16
5/8
3/8
5/8
1.29
96
1.38
1/2
400 kcmil
3/8
1.40
W32VT (2)
W32VT (2)
W32RT (2)
U32RT (2)
U30ART (2)
Blue
19
1-1/4
1.38
7/8
1.40
450 kcmil
5/8
1.48
W33VT (2)
W33VT (2)
W33RT (2)
U33RT (2)
Gray
326 1-9/16
5/8
1.55
Y644M (1)
1
1.55
3/8
500 kcmil
240
1/2
1.55
W34VT (2)
W34VT (2)
W34RT (2)
U34RT (2)
U31ART (2)
Brown
20 1-7/16
1.55
3/4
1.55
7/8
1.55
550 kcmil
5/8
1/2
1.65
1.74
1.74
-
-
U35RT (2)
Yellow
21
1-3/4
600 kcmil
300
5/8
-
-
U36RT (2)
Green
22
1-3/4
* Use PUADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM
2
conductor sizes listed are the recommendations
for Class 2 conductor.
▲
See tooling section of this catalog for complete tool and die
listings.
◆
For applications greater than 2000 Volts, consult cable