ACPL-M21L, ACPL-021L and ACPL-024L
Low Power, 5 MBd Digital CMOS Optocoupler
Data Sheet
Lead (Pb) Free
RoHS 6 fully
compliant
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
Description
ACPL-M21L (single channel SO-5 package), ACPL-021L
(single channel SO-8 package) and ACPL-024L (dual
channel SO-8 package) are optically-coupled logic gates.
The detector IC has CMOS output stage and optical
receiver input stage with built-in Schmitt trigger to
provide logic-compatible waveforms, eliminating the
need for additional waveshaping.
An internal shield on the ACPL-M21L/021L/024L guar-
antees common mode transient immunity of 25 kV/μs
at a common mode voltage of 1000 V. The ACPL-x2xL
optocouplers' series operates from a 2.7 to 5.5 V
supply with guaranteed AC and DC performance from an
extended temperature range of -40° C to 105° C. Glitches
free output upon power-up and power-down of optocou-
pler.
Features
CMOS output
Wide supply voltage: 2.7 V – 5.5 V
Low power supply current I
DD
: ≤ 1.1 mA max
Low forward current I
F
: 1.6 mA min
Speed: 5 MBd typ
Pulse width distortion (PWD): 200 ns max
Propagation delay skew (tpsk): 220 max
Propagation delay (tp): 250 ns max
Common mode rejection: 25 kV/s min at V
CM
= 1000 V
Hysteresis: 0.2 mA typ
Temperature range: -40° C to 105° C
Safety and regulatory approvals
– UL 1577 recognized – 3750 Vrms for 1 minute for
ACPL-M21L/021L/024L
6
Functional Diagram
Anode
1
VDD
VO
GND
TRUTH TABLE
(POSITIVE LOGIC)
LED
ON
OFF
– CSA Approval
– IEC/EN 60747-5-5, Approval for Reinforced Insulation
5
VO
HIGH
LOW
Cathode
3
Shield
4
Applications
Low isolation of high speed logic systems
Computer peripheral interface
V
DD
V
01
V
02
GND
ACPL-M21L
NC
Anode
Cathode
NC
1
2
3
4
Shield
8
7
6
5
VDD
VO
NC
GND
Anode1
Cathode1
Cathode2
Anode2
1
2
3
4
8
7
6
5
Microprocessor system interface
Ground loop elimination
Pulse transformer replacement
High speed line receiver
Power control systems
Shield
ACPL-021L
ACPL-024L
A 0.1
F
bypass capacitor must be connected between pins Vdd and GND
Ordering Information
ACPL-M21L, ACPL-024L and ACPL-021L are UL Recognized with 3750 V
rms
for 1 minute per UL1577.
Option
Part number
ACPL-M21L
RoHS Compliant
-000E
-060E
-500E
-560E
Package
SO-5
Surface
Mount
X
X
X
X
Tape & Reel
UL1577
5000 V
rms
/
1 Minute Rating
IEC/EN 60747-5-5 Quantity
100 per tube
X
100 per tube
1500 per reel
X
X
1500 per reel
100 per tube
100 per tube
1500 per reel
X
X
1500 per reel
100 per tube
100 per tube
1500 per reel
X
1500 per reel
X
X
ACPL-024L
-000E
-060E
-500E
-560E
SO-8
X
X
X
X
X
X
ACPL-021L
-000E
-060E
-500E
-560E
SO-8
X
X
X
X
X
X
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
Example 1:
ACPL-M21L-500E to order product of SO-5 package in Tape and Reel packaging with RoHS compliant.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
2
Package Outline Drawings
ACPL-M21L SO-5 Package
LAND PATTERN RECOMMENDATION
0.3
(0.01)
1.3
(0.05)
0.5
(0.02)
4.4 ± 0.1
(0.173 ± 0.004)
MXXX
XXX
7.0 ± 0.2
(0.276 ± 0.008)
4.4
(0.17)
8.27
(0.325)
0.4 ± 0.05
(0.016 ± 0.002)
3.6 ± 0.1*
(0.142 ± 0.004)
1.8
(0.072)
2.5
(0.10)
2.5 ± 0.1
(0.098 ± 0.004)
0.102 ± 0.102
(0.004 ± 0.004)
0.15 ± 0.025
(0.006 ± 0.001)
7° MAX.
1.27 BSC
(0.050)
Dimensions in millimeters (inches).
Note: Foating Lead Protrusion is 0.15 mm (6 mils) max.
* Maximum Mold flash on each side is 0.15 mm (0.006).
0.71 MIN
(0.028)
MAX. LEAD COPLANARITY
= 0.102 (0.004)
3
ACPL-024L/021L SO-8 Package
LAND PATTERN RECOMMENDATION
1.9
(0.075)
0.64
(0.025)
8
7
6
5
3.937 ± 0.127
(0.155 ± 0.005)
XXXV
YWW
5.994 ± 0.203
(0.236 ± 0.008)
TYPE NUMBER
(LAST 3 DIGITS)
DATE CODE
4
3.95
(0.156)
7.49
(0.295)
PIN ONE
0.406 ± 0.076
(0.016 ± 0.003)
1
2
3
1.270 BSC
(0.050)
* 5.080 ± 0.127
(0.200 ± 0.005)
7°
1.3
(0.5)
45° X
0.432
(0.017)
3.175 ± 0.127
(0.125 ± 0.005)
0 ~ 7°
1.524
(0.060)
0.203 ± 0.102
(0.008 ± 0.004)
0.228 ± 0.025
(0.009 ± 0.001)
* Total package length (inclusive of mold flash)
5.207 ± 0.254 (0.205 ± 0.010)
Dimensions in Millimeters (Inches).
Note: Floating lead protrusion is 0.15 mm (6 mils) max.
Lead coplanarity = 0.10 mm (0.004 inches) max.
Option number 500 not marked.
0.305 MIN.
(0.012)
Solder Reflow Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-M21L/024L/021L is approved by the following organizations:
UL
Approval under UL 1577, component recognition program up to V
ISO
= 3750 V
RMS
for ACPL-M21L/024L/021L
CSA
Approval under CSA Component Acceptance Notice #5.
IEC/EN 60747-5-5 (Option 060 only)
4
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
CTI
Symbol
L(101)
L(102)
ACPL-M21L
5
5
0.08
ACPL-024L
ACPL-021L
4.9
4.8
0.08
Units
mm
mm
mm
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
175
IIIa
175
IIIa
Volts
IEC/EN 60747-5-5 Insulation Characteristics* (Option 060)
Characteristic
Description
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 600 V
rms
for rated mains voltage ≤ 1000 V
rms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test
with t
m
= 1 sec, Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test,
t
m
= 10 sec, Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
= 60 sec)
Safety-limiting values – maximum values allowed in
the event of a failure.
Case Temperature
Input Current**
Output Power**
Insulation Resistance at TS, V
IO
= 500 V
*
Symbol
ACPL-M21L/
024L/021L
I – IV
I – III
I – II
55/105/21
2
Unit
V
IORM
V
PR
567
1063
V
peak
V
peak
V
PR
V
IOTM
896
V
peak
V
peak
6000
T
S
I
S, INPUT
P
S, OUTPUT
R
S
150
150
600
>10
9
°C
mA
mW
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of P
S
and I
S
on ambient temperature.
5